The fatigue behaviors of high-strength bearing steel were investigated with rotating bending fatigue loading with a frequency of 52.5 Hz. It was revealed that the high-strength steel tended to initiate at interior non-metallic inclusions in a very high-cycle fatigue regime. During fractography observation, it was also seen that the inclusion acting as a failure-originating site was seldom smaller than 10 μm. Moreover, prior austenite grains could also act as the originating source of failure when inclusion was absent. The crystal plasticity finite element method (CPFEM) was adopted to simulate the residual stress distribution around non-metallic inclusions of different sizes under different loading amplitudes. The accumulated plastic strain around the inclusion suggested that the existence of inclusion may reduce material strength and lead to more fatigue damage. The value of accumulated plastic strain around different inclusion sizes also resembled the crack nucleation or propagation of the materials. The simulation results also indicated that inclusions smaller than 5 μm had little influence on fatigue lifetimes, while inclusions larger than 10 μm had a significant influence on fatigue lifetimes.
The effective vibration area includes most of the catenary vibration caused by pantograph–catenary interactions and is the basis of the real-time catenary model for hardware-in-the-loop simulation. However, while the length of the effective vibration area is one of the most important parameters of the real-time catenary model, it has not been fully studied at present. In this paper, the length of the effective vibration area is first investigated. A pantograph–catenary interaction model is developed based on the modal superposition method. After the validation of the model, the vibration energy distribution of the catenary is used to determine the length of the effective vibration area based on the converged total energy. The influence of vehicle velocity and contact wire tension on the vibration energy distribution and length of the effective vibration area is investigated. The obtained appropriate length of effective vibration area is validated by a real-time catenary model and online measurement data of the contact force. The investigation results show that the energy distribution of the catenary can accurately determine the length of effective vibration area, and it increases with increasing vehicle velocity but decreases with increasing contact wire tension. The appropriate length of effective vibration area should be at least 160 m (approximately three spans) in the pantograph–catenary system.
1 January 2024 in IET Electrical Systems in Transportation
Wheel flat can seriously affect the wheel–rail contact performance and cause impact vibrations, which significantly threaten the safe operation of railway vehicles. It is crucial to accurately assess the effects of wheel flats on the wheel–rail contact performance and the vibration impact on the traction drive system. However, studies related to wheel flats have focused on the mechanical part and have yet to fully consider the electrical and mechanical parts of the entire traction drive system. Therefore, this paper first builds an electromechanical coupling model based on the electric traction drive system and the locomotive‐track coupling dynamics model. Then, based on this model, the impact of the wheel flat on the electrical and mechanical parts of the traction drive system under different flat lengths, different flat depths, and different vehicle speeds was analyzed. The results indicate that with the increasing depth of the flat spot, the wheel–rail dynamic response, motor rotor speed, and motor torque exhibit more significant fluctuations. Additionally, as the locomotive speed increases, the impact of the flat on the wheel–rail contact performance intensifies. Wheel flats can excite the 1st bending mode of the wheelset, resulting in vibration shocks at 90 Hz.
The electrified railways in mountainous areas are faced with multiple difficulties such as weak power grids, special climatic environments, complex, and dangerous geographical conditions, which poses a great challenge to the reliable power supply of the traction power supply system (TPSS). In order to ensure that the overall reliability level of the TPSS meets the design requirements, this paper proposes a reliability allocation method for the TPSS of electrified railways in mountainous areas. Firstly, based on the characteristics of the interconnected power supply system of traction substation group (TSG) of the electrified railways in mountainous areas, the special topology of the TPSS, as well as the logical relationships between each power supply area and each equipment are sorted out. Secondly, the reliability allocation model of the interconnected power supply system of the TSG is established, and the reliability index of the system is allocated layer-by-layer from the whole system to the TSG according to the design requirements of the overall reliability level of the system. Finally, the reliability allocation model of the traction substation is established, and the reliability index is allocated to the underlying equipment of the traction substation, so as to clarify the reliability requirements of each power supply area and equipment. The results indicate that the reliability allocation results calculated by the proposed method can assist designers to be informed of the reliability objectives of each subsystem and power supply equipment, and can provide insights for related reliability design.
Infrared thermography techniques have proven to be very effective for assessing the fatigue limits of metallic materials with obvious temperature variations. But for some materials, it has been shown that the temperature variation is very limited, and the accuracy of infrared thermographic techniques is not verified. In this study, the fatigue properties of a high-strength steel (SAE52100) were evaluated with traditional fatigue-loading techniques and infrared thermographic methods. The traditional fatigue experiments were loaded at a frequency of 80 Hz with a stress ratio of R = −1, and the fatigue limit at the fatigue lifetime of N = 107 cycles was about 800 MPa. Besides, three additional specimens were loaded with step-by-step increasing stress-loading amplitude, where the maximum temperature increments and temperature distribution were recorded via infrared thermographic techniques. The infrared detections revealed that the maximum value of the temperature increase was only about 1 °C. The fatigue limit was first evaluated based on the maximum temperature variation, then the prediction was refined based on fatigue intrinsic dissipation. The fatigue limits predicted with maximum temperature variation were shown to be 841 MPa, 772 MPa, and 787 MPa, respectively, while the fatigue limits predicted based on fatigue intrinsic dissipation were 793 MPa, 791 MPa, and 789 MPa. Finally, an FEM simulation of temperature variation during fatigue loading was implemented to verify the experimental results. This study provides a solid foundation for the applications of infrared thermography techniques for materials with lower energy dissipations.
The off-line discharge between the pantograph and catenary (PAC) occurs frequently in the actual operation of an electric locomotive, which affects the quality of the received current and the service life of the pantograph. The current experiments on the off-line discharge between the PAC are mainly low-power ones and the models established are static. To study the electrical behaviors during the PAC relative motion under the actual working conditions, in this paper, the voltage and current of the contact wire (CW) during its motion are measured. And the electrical behaviors during the rise, fall and reciprocating motions of the pantograph are investigated by combining a finite element method (FEM) model based on the magnetohydrodynamics with the auto transformer (AT) traction network circuit and moving mesh method. It is found that the harmonic frequencies are mainly in the range of 0-30 MHz. The voltage distortion is more obvious during the fall of the pantograph. And the negative polarity spike pulse has a larger amplitude and occurs more frequently. The novelty of this paper lies in the experimental test with the high current and high power, as well as the systematic analysis of the electrical behaviors and multi-physical field evolution during the motion of the pantograph under the working conditions. Its contribution is to present an effective method to study the dynamic behaviors of the PAC. The research results can provide an important reference for the identification of the electrical characteristics of the PAC and the protection of the PAC equipment.