Domenico Sfondrini

Dr. Domenico Sfondrini


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
FBFedericoMaria Bella
FedericoMaria Bella
ABAlessandra Bonfichi
Alessandra Bonfichi
Ciro EspositoCiro Esposito
Ciro Esposito
CZChristian Zanza
Christian Zanza
Abdelouahab BellouAbdelouahab Bellou
Abdelouahab Bellou
Gabriele SavioliGabriele Savioli
Gabriele Savioli
The Extended Focused Assessment with Sonography for Trauma (eFAST) plays a crucial role in the emergency department (ED) by providing rapid and non-invasive diagnostic information in trauma patients. It is a diagnostic-free fluid detection technique that uses sonography to assess trauma in different anatomical windows of the chest and abdomen and has been accepted in multiple studies as the initial diagnostic tool for torso injuries in blunt abdominal trauma. By promptly identifying potentially life-threatening injuries, such as haemoperitoneum, haemothorax, and cardiac tamponade, eFAST facilitates timely intervention and improves patient outcomes in the ED. The eFAST exam is reliable, with high sensitivity and specificity, even when performed by non-radiological personnel, saving time and resources in the chaotic emergency environment. This review aims to assess the diagnostic reliability and limitations of eFAST in different trauma conditions and to outline its goals in trauma critical care and in “ABCDE” resuscitation.

28 November 2023 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
DSDomenico Sfondrini
Domenico Sfondrini
SMStefano Marelli
Stefano Marelli

2 September 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
Andrea ScribanteAndrea Scribante
Andrea Scribante
DMDario De Martis
Dario De Martis
FVFilippo Vezzoni
Filippo Vezzoni
MMMaria Mirando
Maria Mirando
DSDomenico Sfondrini
Domenico Sfondrini
PBPaolo Zampetti Branchini
Paolo Zampetti Branchini
Background: Dental implants have become integral in restoring partially or completely edentulous patients due to their reported long-term success. While titanium remains the primary material for implants and abutments due to its mechanical properties and biocompatibility, zirconia has emerged as a promising alternative, especially for aesthetic regions. This systematic review aimed to assess whether zirconia abutments present a rational alternative to titanium in modern implantology, focusing on their mechanical and clinical performances. Method: The workflow used for this review included the PRISMA checklist. The eligibility criteria included various study types, with a preference given to clinical trials. The search strategy employed the PICO model, including a large number of relevant studies, and online research was carried on the online databases PubMed and Scopus, with “implant” AND “abutment” AND “zirconia” and “zirconia abutment” AND “mechanical properties” used as search strings. Results: Six clinical studies were included with an adequate follow-up and patient cohort; they suggest that while zirconia abutments offer improved aesthetics and biological integration, concerns persist regarding their mechanical properties, particularly regarding their fatigue resistance and connection stability. In vitro studies have revealed differences between titanium and zirconia abutments, with the latter showing greater susceptibility to fatigue-induced deformation and fretting wear. The clinical outcomes, however, demonstrate favourable long-term performance, with zirconia abutments promoting healthy soft tissue conditions. CAD/CAM technologies enable the precise customization of zirconia abutments, enhancing their compatibility and aesthetic outcomes. Conclusions: Although this review faces limitations due to the scarcity of comparative studies and varied methodologies, it underscores the potential of zirconia abutments in implantology. In conclusion, while zirconia abutments offer promising advantages, the careful consideration of patient-specific factors and the long-term outcomes is warranted for their optimal utilisation in implant-supported prostheses.

1 December 2024 in Acta Otorhinolaryngologica Italica
Verified
Journal Article
Open access
PDF file
DSDomenico Sfondrini
Domenico Sfondrini
SMStefano Marelli
Stefano Marelli
RPRachele Patriarca
Rachele Patriarca
SLSabino Luzzi
Sabino Luzzi
GBGiada Beltramini
Giada Beltramini
FSFrancesca Sfondrini
Francesca Sfondrini
Osteochondroma (OC) is a common bone tumour that rarely affects the mandibular condylar process. This pathology can show typical clinical features, such as facial asymmetry, deviation of the chin and dental inferior midline, changes in condylar morphology and malocclusion with an increased posterior mandibular vertical height. The management of condylar OC is a debated topic among surgeons. Most of them combine systematically condylectomy with orthognathic surgery while only few others perform in the first instance only condylectomy followed by functional therapy. A case of a 32-year-old female diagnosed with a mandibular condylar OC successfully treated with condylectomy alone is presented. A literature review is carried out focusing on surgical management, clinical and imaging features, highlighting the differences between OC and other condylar growing lesions.When maxillary alterations are not present or are mild as in the presented patient, the low condylectomy alone, followed by elastic functional therapy, can correct both the aesthetic and the occlusal disorders resulting from condylar OC removal. In case of severe dentoalveolar maxillary compensation, orthognatic surgery must be performed with the low condylectomy to quickly correct facial symmetry and occlusion.

13 August 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Maria Francesca SfondriniMaria Francesca Sfondrini
Maria Francesca Sfondrini
MPMaurizio Pascadopoli
Maurizio Pascadopoli
Paola GandiniPaola Gandini
Paola Gandini
LPLORENZO PREDA
LORENZO PREDA
DSDomenico Sfondrini
Domenico Sfondrini
Andrea ScribanteAndrea Scribante
Andrea Scribante
Objectives: Orthodontists are often asked to remove fixed retainers before patients undergo magnetic resonance imaging (MRI). The present in vitro study was designed to analyze the heating and bonding efficacy of stainless steel multibraided fixed retainers after 1.5- and 3-tesla (T) MRI. Materials and methods: A total of 180 human mandibular incisors were used to create 45 specimens of four teeth each, divided into nine groups. Handmade multibraided fixed retainers of three different sizes, defined by the diameter of the initial wire used (0.008″, 0.010″ and 0.012″), were tested. Three groups underwent MRI at 1.5 T, another three groups underwent MRI at 3 T and the last three groups did not undergo MRI. Temperature was assessed before and after MRI. Shear bond strength (SBS) and adhesive remnant index (ARI) were assessed after MRI for all groups. Data were statistically analyzed (p < 0.05). Results: After 1.5 T exposure, no significant temperature increase from T0 to T1 was observed in any of the groups (p > 0.05). Regarding the 3 T groups, a significant difference from T0 to T1 was found for all the groups (p < 0.05). Temperature changes were not clinically relevant, as they were less than 1 °C for all groups except for group 3 (ΔT0–T1: 1.18 ± 0.3 °C) and group 6 (ΔT0–T1: 1.12 ± 0.37 °C). Furthermore, there were no significant differences between the temperature variations associated with different wire diameters (p > 0.05). Conclusions: No significant changes in SBS or ARI were found (p > 0.05). Clinical significance: Since overheating was irrelevant and adhesion values did not change, the tested devices were concluded to be safe for MRI examinations at 1.5 T and 3 T.

30 May 2026 in Hygiene
Verified
Journal Article
Open access
PDF file
Andrea ScribanteAndrea Scribante
Andrea Scribante
AGAnita Groppi
Anita Groppi
PBPaolo Zampetti Branchini
Paolo Zampetti Branchini
DSDomenico Sfondrini
Domenico Sfondrini
MMMarco Monticone
Marco Monticone
Pain is a complex experience that encompasses both physical and emotional dimensions. Stomatognathic Pain (SP) affects the anatomical and functional structures of the stomatognathic system, which is involved in essential activities such as mastication, deglutition, and phonation. Consequently, SP can significantly impair patients’ quality of life, affecting physiological, psychological, and social well-being. Precision Medicine (PM) is an emerging patient-centered approach that enables healthcare providers to tailor diagnostic and therapeutic strategies according to each patient’s biochemical, physiological, environmental, and behavioral profile. The aim of this narrative review is to highlight PM tools for the diagnosis and treatment of SP and to explore their contribution to personalized management. A literature search was conducted in the PubMed and Scopus databases using the keywords “orofacial pain”, “stomatognathic pain”, “precision medicine”, “pain management”, “pain assessment”, “pain treatment”, and “patient-centered care”. Current evidence suggests that PM can improve SP management by identifying pathogenic mechanisms, clarifying disease etiology, and integrating advanced molecular and digital technologies. Emerging approaches, including genetic profiling, biomarker analysis, artificial intelligence–based diagnostics, targeted therapies, individualized rehabilitation, and behavioral interventions, may support personalized treatment and facilitate the development of patient-centered care models, ultimately reducing the burden of SP and improving clinical outcomes and quality of life.