To evaluate the change in backward-directed and forward-directed corneal straylight in eyes after corneal collagen crosslinking (CXL) and its correlation with corrected distance visual acuity (CDVA) and changes in corneal topography. Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. Retrospective cohort study. Following the Dresden protocol, corneal CXL was performed in eyes with progressive keratoconus. Corneal light scattering was evaluated using densitometry measurements from different corneal layers and zones obtained using Scheimpflug tomography (Pentacam HR). Retinal straylight values were measured using the C-Quant device. The CDVA was recorded during each follow-up examination. Changes in corneal topography were measured using Scheimpflug tomography. The study evaluated 31 eyes of 31 patients. The mean densitometry of different corneal layers and in 3 different zones increased 3 months postoperatively and decreased thereafter. The mean densitometry in the 0.0 to 2.0 mm zone remained statistically significantly elevated after 12 months (P < .05). The mean preoperative retinal straylight was 1.14 log(s) ± 0.28 (SD). The mean straylight peaked after 1 month and then decreased continuously but remained elevated after 1 year at 1.26 ± 0.21 log(s). There was an increase in CDVA and flattening of the steepest keratometry (K) value (maximum K). Eyes with the greatest maximum K reduction also had the highest densitometry values. Crosslinking-induced stromal changes resulted in an increase in densitometry, especially in the anterior stroma of the central (0.0 to 2.0 mm) zone. These changes correlated with an increase in retinal straylight but not with the postoperative CDVA values.
To evaluate pachymetry changes during standard corneal crosslinking (CXL) and the effect of closed eyelids and hypotonic riboflavin in thin corneas. Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. Comparative case series. Eyes with progressive keratoconus had standard epithelium-off CXL. In Group 1, a lid speculum was used during the procedure. In Group 2, the lids were closed during saturation with riboflavin. In Group 3, hypotonic riboflavin was used. In Groups 1 and 2, swelling was performed with hypotonic riboflavin if pachymetry was less than 400 μm. The thinnest corneal pachymetry (TCP) was measured preoperatively, after epithelium removal, and every 10 minutes thereafter. Thirty-five eyes were evaluated. After epithelium removal, the mean TCP was 401 μm ± 15 (SD), 411 ± 35 μm, and 400 ± 24 in Groups 1, 2, and 3, respectively. In Group 1, the TCP decreased to 355 ± 23 μm after the first 30 minutes. In Group 2, the TCP remained stable throughout the saturation phase. In Group 3, the TCP increased. During the irradiation phase, a reduction in pachymetry occurred in all groups. Thinnest corneal pachymetry readings less than 400 μm were found in all eyes irrespective of the protocol. Corneal desiccation with riboflavin with 20% dextran can be avoided when removing the lid speculum during saturation with riboflavin. The use of hypotonic riboflavin solution increased corneal pachymetry, although the final TCP remained unchanged. To increase endothelial safety, new isooncotic solutions are needed.
To evaluate monocular and binocular depth of focus in eyes with different multifocal intraocular lens (IOLs) systems. Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. In this comparative interventional study, binocular implantation of multifocal IOLs was performed in 3 groups. In the first group, 26 eyes of 13 patients received asymmetric Acri. Twin (Acri.Tec) IOLs, a near-weighted 733D in 1 eye and a distance-weighted 737D in the fellow eye. In the second group, 26 eyes of 13 patients received a diffractive 811E IOL (Pharmacia). In the third group, 26 eyes of 13 patients received a refractive Array IOL (AMO). The visual acuity was tested monocularly and binocularly starting at 6 m in 0.50 diopter (D) defocusing steps. Distance visual acuity was best in eyes with the distance-dominated 737D IOL; eyes with the other IOLs had comparable results. Binocular distance visual acuity was comparable between the Acri. Twin group and the 811E group. The Acri. Twin group had better distance visual acuity than the Array group (P< or =.048). Near visual acuity was best in eyes with the near-weighted 733D, followed by the 737D and the 811E. Patients with Array IOLs had worse visual acuities at reading distance (between 33 cm and 40 cm) (P< or =.001). Patients with diffractive bifocal IOLs had better results than patients with refractive multifocal IOLs at reading distance (P< or =.018). The diffractive IOLs performed better than refractive IOLs. Asymmetric-weighted IOLs provided better binocular depth of field.