Micheal Tarver

Mr. Micheal Tarver


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2018 in Brain Sciences
Verified
Journal Article
Open access
PDF file
MTMicheal Tarver
Micheal Tarver
TSTyler Schmidt
Tyler Schmidt
Michael T. KoltzMichael T. Koltz
Michael T. Koltz
The authors present a unique case of recurrent stroke, discovered to be secondary to hemorrhagic conversion of microemboli from a mechanical aortic valve despite anticoagulation with Coumadin. The complexity of this case was magnified by the patient’s young age, a mechanical heart valve (MHV), and a need for anticoagulation to maintain MHV patency in a setting of potentially life-threatening intracranial hemorrhage. Anticoagulant and antiplatelet therapy are risk factors for hemorrhagic conversion post-cerebral ischemia; however, the pathophysiology underlying endothelial cell dysfunction causing red blood cell extravasation is an active area of basic and clinical research. The need for randomized clinical trials to aid in the creation of standardized treatment protocol continues to go unmet. Consequently, there is marked variation in therapeutic approaches to treating intracranial hemorrhage in patients with an MHV. Unfortunately, patients with an MHV are considered at high thromboembolic (TE) risk, and these patients are often excluded from clinical trials of acute stroke due to their increased TE potential. The authors feel this case represents an example of endothelial dysfunction secondary to microthrombotic events originating from an MHV, which caused ischemic stroke with hemorrhagic conversion complicated by the need for anticoagulation for an MHV. This case offers a definitive treatment algorithm for a complex clinical dilemma.

17 April 2018 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PSPraveen Satarasinghe
Praveen Satarasinghe
DHDavid Kojo Hamilton
David Kojo Hamilton
MTMicheal Tarver
Micheal Tarver
RBRobert J. Buchanan
Robert J. Buchanan
Michael T. KoltzMichael T. Koltz
Michael T. Koltz
Object. Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D), computer-assisted virtual neuronavigation improves the precision of PS placement and minimization steps. Methods. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. (1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at an anatomical entry point with a screen projection showing a virtual screw. (2) A Navigated Stryker Cordless Driver with an appropriate tap was used to access the vertebral body through a pedicle with a screen projection again showing a virtual screw. (3) A Navigated Stryker Cordless Driver with an actual screw was used with a screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Results. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images taken to confirm hardware placement. Conclusions. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.

5 April 2018 in Preprints.org
Verified
Preprint
Open access
PDF file
PSPraveen Satarasinghe
Praveen Satarasinghe
DHDavid Kojo Hamilton
David Kojo Hamilton
MTMicheal Tarver
Micheal Tarver
RBRobert J. Buchanan
Robert J. Buchanan
Michael T. KoltzMichael T. Koltz
Michael T. Koltz
Object. Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D) computer-assisted virtual neuronavigation improves the precision of PS placement and minimize steps. Methods. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. 1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at anatomical entry point with screen projection showing virtual screw. 2) Navigated Stryker Cordless Driver with appropriate tap was used to access vertebral body through pedicle with screen projection again showing virtual screw. 3) Navigated Stryker Cordless Driver with actual screw was used with screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Results. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images to confirm hardware placement. Conclusions. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.