Fibre optic sensors with integrated Bragg gratings are widely used in the diagnostics of machinery and equipment. They achieved their popularity thanks to their relatively simple operating principles. In addition, they allow the continuous monitoring of several variable physical parameters of objects, such as strain or temperature change, which directly translates into immediate feedback regarding potential damage. However, despite the easy-to-understand operating principle, selecting a specific type for a particular application can be problematic. This article aims to present the process of selecting the optimal set of fibre-optic sensors with integrated Bragg grating, which can be used in the process of monitoring the stress state of hanger rods of an engineering object such as an industrial boiler. The hanger rods of such boilers require constant technical supervision; however, the current measurement methods do not provide an effective and non-invasive diagnostic method. Therefore, the authors have undertaken the task of developing a universal diagnostic strategy for hanger rods. To this end, they will present the results of an analysis of the applicability of FBGs, examples of the use of different types of sensors, their installation methods, and the technical capabilities of the equipment necessary to handle the signals recorded with these sensors. Exemplary results of strain measurements of a selected hanger rod performed by the traditional method used now and with a selected FBG fibre optic sensor will be presented. In conclusion, concrete technical suggestions will be presented to be implemented in the existing industrial facility during the next part of the study.
Issues related to the proper design of power boiler elements taking account of thermal loads are still relevant in this era of increasing variability of the boiler power output over time. The aim of this work is to present a thermal and strength analysis for a section of the membrane wall of a steam boiler, designed and manufactured in compliance with international standards, and approved for operation by a pressure equipment supervisory authority. Although the procedures were followed as required, the boiler membrane wall became cyclically damaged. The cause of such periodic damage to the boiler can be explained based on the conducted analyses.
This study addresses recurring failures of a gas boiler with a steam capacity of 65,000 kg/h, which is operating in a Polish industrial plant. To determine the cause, material examinations were carried out, including chemical composition and microstructural analysis of SA178A steel, as well as strength tests. The results revealed no significant material degradation outside the cracking zones, suggesting that the failures were primarily caused by thermo-mechanical interactions. A finite element model in Ansys Workbench software was developed, incorporating thermal and mechanical boundary conditions, to reproduce the behavior of the critical section. The analysis demonstrated stress concentrations at the junction between the box and the membrane wall, resulting from large thermal displacement differences. The plastic strains under static loading do not exceed 5%, which implies that, without considering the cyclic nature of boiler operation, the wall should not experience failure. Analysis taking into account only 3 full operating cycles indicates a continuous increase in plastic deformation, which leads to the occurrence of ratcheting. To mitigate these effects, a modification of the sealing box design was proposed. Simulations indicated a reduction in plasticized zones by approximately 65%, and the effectiveness of the solution was confirmed by two years of failure-free operation. The findings highlight the importance of an integrated diagnostic, numerical, and design approach to improving boiler durability.
Hanger rods intended for boiler suspensions on a metal structure require a special design approach that considers the total weight of the boiler structure that is to be carried. Unfortunately, a large reserve in the rods’ carrying capacity does not always guarantee the failure-free operation of a boiler. For this reason, it is very important to monitor the forces acting in the rods. Any negligence in this matter might cause a local excess of stresses in the boiler pressure part and result in periodic shutdowns of the boiler. Therefore, in order not to let this happen, adequate computational methods have to be developed. To date, the methods described in the literature and in design requirements have concentrated, first of all, on analyses of the boiler individual subassemblies or on small boiler units supported from the bottom at just a few points. The aim of this paper was to conduct a numerical analysis for a real high-capacity power boiler. The computations were performed based on experimentally measured forces in the hanger rods, and the results were verified by comparing the areas of stress concentration against the area where the boiler structure was regularly damaged.