Arne Bergsch

Arne Bergsch


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
ABArne Bergsch
Arne Bergsch
JDJan Degenhardt
Jan Degenhardt
RSRüdiger Stressig
Rüdiger Stressig
HDHeiko Dudwiesus
Heiko Dudwiesus
Oliver  GraupnerOliver Graupner
Oliver Graupner
JRJochen Ritgen
Jochen Ritgen
Background: This study assesses the effects of the ‘Radiant’ image enhancement technique on fetal nuchal translucency (NT) measurements during first-trimester sonographic exams. Methods: A retrospective analysis of 263 ultrasound images of first-trimester midsagittal sections was conducted. NT measurements were obtained using a semi-automatic tool. Statistical methods were applied to compare NT measurements with and without ‘Radiant’ enhancement. An in vitro setup with predefined line distances provided additional data. Results: Incremental increases in NT measurements were observed with varying levels of ‘Radiant’ application: an average increase of 0.19 mm with ‘Radiant min’, 0.24 mm with ‘Radiant mid’, and 0.30 mm with ‘Radiant max.’ The in vitro results supported these findings, showing consistent effects on line thickness and measurement accuracy, with the smallest mean deviation occurring at the ‘Radiant mid’ setting. Conclusions: ‘Radiant’ image enhancement leads to significant increases in NT measurements. To avoid systematic biases in clinical assessments, it is advisable to disable ‘Radiant’ during NT measurement procedures. Further studies are necessary to corroborate these findings and to consider updates to the NT reference tables based on this technology.

13 May 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
ABArne Bergsch
Arne Bergsch
JDJan Degenhardt
Jan Degenhardt
RSRüdiger Stressig
Rüdiger Stressig
HDHeiko Dudwiesus
Heiko Dudwiesus
OGOliver Graupner
Oliver Graupner
JRJochen Ritgen
Jochen Ritgen
Background: This study assesses the effects of the ‘Radiant’ image enhancement technique on fetal nuchal translucency (NT) measurements during first trimester sonographic ex-ams. Methods: A retrospective analysis of 263 ultrasound images of first trimester midsagittal sections was conducted. NT measurements were obtained using a semi-automatic tool. Statistical methods were applied to compare NT measurements with and without ‘Radi-ant’ enhancement. An in-vitro setup with predefined line distances provided additional data. Results: Incremental increases in NT measurements were observed with varying levels of ‘Radiant’ application: An average increase of 0.19 mm with ‘Radiant min’, 0.24 mm with ‘Radiant mid’ and 0.30 mm with ‘Radiant max.’ The in-vitro results supported these findings, showing consistent effects on line thickness and measurement accuracy, with the smallest mean deviation occurring at the ‘Radiant mid’ setting. Conclusions: ‘Radiant’ image enhancement leads to significant increases in NT measure-ments. To avoid systematic biases in clinical assessments, it is advisable to disable ‘Radi-ant’ during NT measurement procedures. Further studies are necessary to corroborate these findings and to consider updates to the NT reference tables based on this technology.