Ming Zhan

Prof. Ming Zhan


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2014 in CrystEngComm
Verified
Journal Article
Closed access
PDF file
XLXiaoqing Li
Xiaoqing Li
XSXiangming Su
Xiangming Su
PLPing Liu
Ping Liu
JLJie Liu
Jie Liu
ZYZhiling Yao
Zhiling Yao
MZMing Zhan
Ming Zhan
A red phosphor K 2 SiF 6 :Mn 4+ nanorod is successfully prepared through an efficient one-step method at room temperature for 30 min. Under UV excitation, K 2 SiF 6 :Mn 4+ nanorods show better red emission corresponding to the characteristic lines of Mn 4+ compared to bulk materials.

10 April 2024 in Journal of Chromatography A
Verified
Journal Article
Open access
ZZZhongheng Zhang
Zhongheng Zhang
QZQing Zhang
Qing Zhang
YXYe Xi
Ye Xi
YZYing Zhou
Ying Zhou
MZMing Zhan
Ming Zhan
Volatile organic compounds (VOCs) are a group of ubiquitous environment pollutants especially released into the workplace. Assessment of VOCs exposure in occupational populations is therefore a crucial issue for occupational health. However, simultaneous biomonitoring of a variety of VOCs is less studied. In this study, a simple and sensitive method was developed for the simultaneous determination of 51 prototype VOCs in urine by headspace-thermal desorption coupled to gas chromatography-mass spectrometry (HS-TD-GC-MS). The urinary sample was pretreated with only adding 0.50 g of sodium chloride to 2 mL of urine and 51 VOCs should be determined with limits of detection (LODs) between 13.6 ng/L and 24.5 ng/L. The method linearity ranged from 0.005 to 10 μg/L with correlation coefficients (r) of 0.991 to 0.999. The precision for intraday and inter-day, measured by the variation coefficient (CV) at three levels of concentration, was below 15 %, except for 4-isopropyl toluene, dichloromethane, and trichloromethane at low concentration. For medium and high levels, recoveries of all target VOCs were within the standard range, but 1,1-dichloropropene and styrene, which were slightly under 80 % at low levels. In addition, the proposed method has been used to determine urine samples collected in three times (before, during and after working) from 152 workers at four different factories. 41 types of prototype VOCs were detected in workers urine. Significant differences (Kruskal-Wallis chi-squared = 117.18, df = 1, P < 0.05) in the concentration levels of VOCs between the exposed and unexposed groups were observed, but not between the three sampling times (Kruskal-Wallis chi-squared = 3.39, df = 2, P = 0.183). The present study provides an alternative method for biomonitoring and assessing mixed exposures to VOCs in occupational populations.

27 May 2022 in Science of The Total Environment
Verified
Journal Article
Closed access
FHFengchan Han
Fengchan Han
GCGuanghua Chen
Guanghua Chen
GTGonghua Tao
Gonghua Tao
JXJingshan Xu
Jingshan Xu
HZHuijun Zhang
Huijun Zhang
Weiwei ZhengWeiwei Zheng
Weiwei Zheng

27 October 2014 in RSC Advances
Verified
Journal Article
Closed access
PDF file
HLHong Liu
Hong Liu
PLPing Liu
Ping Liu
XSXiangming Su
Xiangming Su
JLJie Liu
Jie Liu
XLXiaoqing Li
Xiaoqing Li
MZMing Zhan
Ming Zhan
Highly crystallized micro/nano-sized Y 2 O 2 S were prepared through a one-pot mild solvothermal synthesis. By simply adjusting the amount of initial sulfur powder, the morphology and assembled structures can be well controlled.

13 June 2024 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
ZDZhiyuan Du
Zhiyuan Du
XWXiaoyi Wei
Xiaoyi Wei
XHXiaohua Hu
Xiaohua Hu
YZYijing Zhao
Yijing Zhao
GCGuanghua Chen
Guanghua Chen
Weiwei ZhengWeiwei Zheng
Weiwei Zheng
Organophosphate esters (OPEs) are widely used as flame retardants and plasticizers, which are of growing concern due to their endocrine-disrupting effects, developmental toxicity, and potential carcinogenicity. However, data on human exposure to OPEs is still scarce. In this study, a relatively simple and efficient method with less serum consumption for the detection of OPEs in human serum was developed and validated. Nine OPEs in 200 μL of human serum were extracted by an acetonitrile–formic acid system and analyzed using ultra-high-performance liquid chromatography–quadrupole tandem time-of-flight high-resolution mass spectrometry. Several experiments were conducted to optimize the chromatographic and mass spectrometric conditions as well as sample preparation to obtain a more sensitive and efficient analytical protocol. The proposed method was examined in terms of its linearity, accuracy, precision, detection limit, and matrix effect. The matrix-spiked recoveries of the target OPEs ranged from 83.3% to 111.1%, with relative standard deviations between 2.7% and 16.6%. The detection limits were within (0.002 to 0.029) ng mL−1, while the quantification limits were within (0.007 to 0.098) ng mL−1. The internal standard-corrected matrix effects varied from 82.7% to 113.9%. Finally, the method was applied to detect OPEs in actual human serum samples. All nine OPEs were detected in 269 serum samples to varying degrees, with the average concentrations ranging from (0.08 to 1.77) ng mL−1. After validation, the method was found to be simple in pretreatment, high in sensitivity, good in practicality, and suitable for exposure evaluation of OPEs in populations.

22 November 2024 in Science of The Total Environment
Verified
Journal Article
Closed access
WQWei Qiu
Wei Qiu
SYShengju Yin
Shengju Yin
KAKadila Abulaiti
Kadila Abulaiti
XLXinyu Li
Xinyu Li
YLYao Lu
Yao Lu
JZJun Zhang
Jun Zhang