CHIEMEZIE ILONZE

Mr. CHIEMEZIE ILONZE

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2023 in Environmental Science & Technology
Verified
Journal Article
Open access
CBClay Bell
Clay Bell
CICHIEMEZIE ILONZE
CHIEMEZIE ILONZE
ADAidan Duggan
Aidan Duggan
DZDaniel Zimmerle
Daniel Zimmerle

12 June 2024 in Environmental Science & Technology
Verified
Journal Article
Open access
CICHIEMEZIE ILONZE
CHIEMEZIE ILONZE
EEEthan Emerson
Ethan Emerson
ADAidan Duggan
Aidan Duggan
DZDaniel Zimmerle
Daniel Zimmerle
The recent regulatory spotlight on continuous monitoring (CM) solutions and the rapid development of CM solutions have demanded the characterization of solution performance through regular, rigorous testing using consensus test protocols. This study is the second known implementation of such a protocol involving single-blind controlled testing of 9 CM solutions. Controlled releases of rates (6-7100 g) CH4/h over durations (0.4-10.2 h) under a wind speed range of (0.7-9.9 m/s) were conducted for 11 weeks. Results showed that 4 solutions achieved method detection limits (DL90s) within the tested emission rate range, with all 4 solutions having both the lowest DL90s (3.9 [3.0, 5.5] kg CH4/h to 6.2 [3.7, 16.7] kg CH4/h) and false positive rates (6.9-13.2%), indicating efforts at balancing low sensitivity with a low false positive rate. These results are likely best-case scenario estimates since the test center represents a near-ideal upstream field natural gas operation condition. Quantification results showed wide individual estimate uncertainties, with emissions underestimation and overestimation by factors up to >14 and 42, respectively. Three solutions had >80% of their estimates within a quantification factor of 3 for controlled releases in the ranges of [0.1-1] kg CH4/h and > 1 kg CH4/h. Relative to the study by Bell et al., current solutions performance, as a group, generally improved, primarily due to solutions from the study by Bell et al. that were retested. This result highlights the importance of regular quality testing to the advancement of CM solutions for effective emissions mitigation.

21 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
CICHIEMEZIE ILONZE
CHIEMEZIE ILONZE
JWJiayang (Lyra) Wang
Jiayang (Lyra) Wang
ARArvind Ravikumar
Arvind Ravikumar
DZDaniel Zimmerle
Daniel Zimmerle
Quantitative optical gas imaging (QOGI) system can rapidly quantify leaks detected by optical gas imaging (OGI) cameras across the oil and gas supply chain. A comprehensive evaluation of the QOGI system’s quantification capability is needed for the successful adoption of the technology. This study conducted single-blind experiments to examine the quantification performance of the FLIR QL320 QOGI system under near-field conditions at a pseudo-realistic, outdoor, controlled testing facility that mimics upstream and midstream natural gas operations. The study completed 357 individual measurements across 26 controlled releases and 71 camera positions for release rates between 0.1 kg Ch4/h and 2.9 kg Ch4/h of compressed natural gas (which accounts for more than 90% of typical component-level leaks in several production facilities). The majority (75%) of measurements were within a quantification factor of 3 (quantification error of −67% to 200%) with individual errors between −90% and 831%, which reduced to −79% to +297% when the mean of estimates of the same controlled release from multiple camera positions was considered. Performance improved with increasing release rate, using clear sky as plume background, and at wind speeds ≤1 mph relative to other measurement conditions.

8 February 2024 in ChemRxiv
Verified
Preprint
Open access
PDF file
CICHIEMEZIE ILONZE
CHIEMEZIE ILONZE
JWJiayang (Lyra) Wang
Jiayang (Lyra) Wang
ARArvind Ravikumar
Arvind Ravikumar
CBClay Bell
Clay Bell
DZDaniel Zimmerle
Daniel Zimmerle
Quantitative optical gas imaging (QOGI) system can provide rapid quantification of leaks detected by optical gas imaging (OGI) cameras across the oil and gas supply chain. A comprehensive evaluation of the QOGI system’s quantification capability is needed for successful adoption of the technology. This study conducted single-blind experiments to examine the quantification performance of the FLIR QL320 QOGI system under near-field conditions at a pseudo-realistic, outdoor, controlled testing facility that mimics upstream and midstream natural gas operations. The study collected 357 individual measurements across 26 controlled releases with rates between 2 slpm to 88 slpm of compressed natural gas (CNG). The majority (75%) of measurements were within a quantification factor of 3 (quantification error of -67% to 200%) with individual errors between -90% and 831% (i.e. within a factor of 10). Quantification error decreased with increasing controlled release rates. Performance improved when viewing gas plumes against a clear sky as background and at calm wind speed conditions relative to other scenarios. Quantification error varied substantially when the same controlled releases were quantified from different camera positions.

24 December 2025 in Environmental Science & Technology
Verified
Journal Article
Open access
CICHIEMEZIE ILONZE
CHIEMEZIE ILONZE
RDRachel Day
Rachel Day
EEEthan Emerson
Ethan Emerson
ADAidan Duggan
Aidan Duggan
RBRyan Brouwer
Ryan Brouwer
DZDaniel Zimmerle
Daniel Zimmerle
Standardized controlled testing of emerging methane detection solutions is a critical step in demonstrating emissions mitigation equivalence between emerging solutions and existing regulatory-approved leak detection and repair methods, such as ground-based optical gas imaging (OGI) camera surveys, in the United States and Canada. In this study, 12 solutions─including four hand-held OGI cameras, hand-held NextGen solutions, and mobile solutions (automobile- and drone-based)─were evaluated using a single-blind controlled testing protocol at an outdoor facility designed to simulate emissions from a simplified onshore North American oil and gas production facility. Three solutions were retested 3 to 12 months after the initial assessment using the same protocol and facility to evaluate how performance changed over time. Results indicated that hand-held OGI cameras generally achieved better emission source localization accuracy as well as lower 90% probability of detection and false positive fraction compared to other solution categories. The false negative fractions of OGI cameras were comparable to those of hand-held NextGen solutions but generally lower than those of mobile solutions, which exhibited shorter survey durations relative to other categories of hand-held solutions. The performance of two of three solutions improved with repeat testing, highlighting the potential benefit of regular, comprehensive testing for the development of solutions. Overall, the study findings suggest that while several emerging survey solutions showed promising detection and localization capabilities, hand-held OGI cameras demonstrated higher efficacy in identifying and accurately localizing small emission sources.

29 April 2025 in ChemRxiv
Verified
Preprint
Open access
PDF file
FCFancy Cheptonui
Fancy Cheptonui
EEEthan Emerson
Ethan Emerson
CICHIEMEZIE ILONZE
CHIEMEZIE ILONZE
RDRachel Day
Rachel Day
ELEzra Levin
Ezra Levin
DZDaniel Zimmerle
Daniel Zimmerle
Continuous Monitoring (CM) solutions have been identified as a method to address methane emissions at oil and gas (O&G) facilities, as these solutions can facilitate faster emission detection and repair compared to traditional survey methods. This study tested 13 CM solutions over 12 weeks using single-blind controlled testing. Controlled release rates ranged from 0.08 to 6.75 kg CH4/hr and lasted 18 minutes to 8 hours. Six solutions demonstrated 90 % method detection limits (DL90s) within the range of controlled releases, from 0.5 [0.3, 0.6] kg CH4/hr to 6.7 [5.9, 8.0] kg CH4/hr. Of the six solutions, four had False Positive (FP) rates between 7.8% and 14.0% (less than 15%), and four had False Negative rates (FN) of 8.0% to 34.1% (less than 50%). Compared with Ilonze et al., these results show retested solutions balancing method sensitivity with FP and FN rates. All scanning/imaging solutions had high localization (≥ 40%) precision and accuracy to the equipment unit. Eleven of the 13 solutions were tested for quantification. Single quantification estimates exhibited high relative quantification errors, outside the -90 % to 1000% range. The mean quantification error ranged from 33 [0.9, 66] %, 95% CI to 1326 [1003, 1648] %, 95 % CI for small emissions, between 0.1 and 1 kg CH4/hr, and from 3 [-20, 26] %, 95% CI to 3578 [-2832, 9988] %, 95% CI for larger emissions, greater than 1 kg CH4/hr. There were 3 and 9 solutions in the small and large emissions categories, respectively, that had less than 100% relative quantification error. Relative to previous studies, errors in quantification estimates decreased, as did FN and FP rates, with improved DL90s for two of the four retested solutions. These findings highlight that continuous, rigorous testing enhances solution performance, with notable improvements observed across multiple testing programs using the same test protocol.