Guo Xia

Dr. Guo Xia


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2018 in Photonic Sensors
Verified
Journal Article
Open access
PDF file
HHHaibing Hu
Haibing Hu
JBJing Bai
Jing Bai
GXGuo Xia
Guo Xia
WZWenda Zhang
Wenda Zhang
YMYan Ma
Yan Ma
Raman spectrum, as a kind of scattering spectrum, has been widely used in many fields because it can characterize the special properties of materials. However, Raman signal is so weak that the noise distorts the real signals seriously. Polynomial fitting has been proved to be the most convenient and simplest method for baseline correction. It is hard to choose the order of polynomial because it may be so high that Runge phenomenon appears or so low that inaccuracy fitting happens. This paper proposes an improved approach for baseline correction, namely the piecewise polynomial fitting (PPF). The spectral data are segmented, and then the proper orders are fitted, respectively. The iterative optimization method is used to eliminate discontinuities between piecewise points. The experimental results demonstrate that this approach improves the fitting accuracy.

8 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
GXGuo Xia
Guo Xia
CZCuixia Zhou
Cuixia Zhou
SJShiqun Jin
Shiqun Jin
CHChan Huang
Chan Huang
JXJinyu Xing
Jinyu Xing
ZLZhijian Liu
Zhijian Liu
Sensitivity is an important performance index for evaluating surface plasmon resonance (SPR) biosensors. Sensitivity enhancement has always been a hot topic. It is found that the different refractive indices of samples require different combinations of prism and metal film for better sensitivity. Furthermore, the sensitivity can be enhanced by coating two-dimensional (2D) materials with appropriate layers on the metal film. At this time, it is necessary to choose the best film configuration to enhance sensitivity. With the emergence of more and more 2D materials, selecting the best configuration manually is becoming more complicated. Compared with the traditional manual method of selecting materials and layers, this paper proposes an optimization method based on a genetic algorithm to quickly and effectively find the optimal film configuration that enhances sensitivity. By using this method, not only can the optimal number of layers of 2D materials be determined quickly, but also the optimal configuration can be conveniently found when many materials are available. The maximum sensitivity can reach 400°/RIU after optimization. The method provided application value for the relevant researchers seeking to enhance sensitivity.

9 November 2017 in Applied Optics
Verified
Journal Article
Closed access
PDF file
GXGuo Xia
Guo Xia
SWSu Wu
Su Wu
GWGuodong Wang
Guodong Wang
MHMingyong Hu
Mingyong Hu
JXJinyu Xing
Jinyu Xing
A modified optical design for a broadband, high resolution, astigmatism-free Czerny–Turner spectrometer is proposed. Astigmatism is corrected by using cylindrical mirrors over a broad spectral range. The theory and method for astigmatism correction are thoroughly analyzed. The comparison between the modified Czerny–Turner spectrometer and the traditional Czerny–Turner spectrometer is also described in detail. The ray-tracing results show that the RMS spot radius has decreased to 4.2 μm at the central wavelength and 17 μm at the wedge wavelength.

9 March 2017 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
YSY. C. Sun
Y. C. Sun
CHC. Huang
C. Huang
GXGuo Xia
Guo Xia
SJS. Q. Jin
S. Q. Jin
HLH. B. Lu
H. B. Lu
Wavelength calibration is an important step in charge-coupled device (CCD) spectrometers. In this paper, an accurate calibration method is proposed. A model of a line profile spectrum is built at the beginning, followed by noise reduction, bandwidth correction, and automatic peak-seeking treatment. Experimental tests are conducted on the USB4000 spectrometer with a mercury-argon calibration light source. Compared with the traditional method, the results show that this wavelength calibration procedure obtains higher accuracy and the deviations are within 0.1 nm.

19 August 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HHHaibing Hu
Haibing Hu
BZBo Zhang
Bo Zhang
DXDongjian Xu
Dongjian Xu
GXGuo Xia
Guo Xia
Detecting the defects of a battery on the surface and edge has always been difficult, especially for concave and convex ones, thereby seriously affecting its quality. Thus, sub-regional Gaussian and moving average filtering are innovatively proposed in this study considering the effect of the nonuniform background illumination of the battery edge and the difference between the edge background and the internal surface defects of the battery. The battery surface image is divided into two areas, namely, edge area W 1 and inner area W 2 . Gaussian and moving average filtering are carried out row-by-row and column-by-column in the inner area W 2 and the edge area W 1 , respectively. The algorithm is tested on 600 battery samples that mainly possess concave and convex defects. The proposed method has higher detection accuracy and lower omission detection rate than the traditional unpartitioned processing method, especially in detecting the accuracy of edge defects. The accuracy rates were approximately 20% higher than that obtained by the traditional processing algorithm. The proposed method has remarkable real-time performance that can process four 8192 × 10,240 pixel battery images per second, thereby meeting the industrial production line speed requirements while satisfying accuracy. The proposed method has been applied in actual production for defect inspection.

3 August 2017 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
SJS. Q. Jin
S. Q. Jin
CHC. Huang
C. Huang
GXGuo Xia
Guo Xia
MHM. Y. Hu
M. Y. Hu
ZLZ. J. Liu
Z. J. Liu
Light-emitting diodes (LEDs) are widely employed in industrial applications and scientific research. However, spectral distortions will occur due to the broadening effects of the spectrometer when an LED spectrum is obtained with a spectrometer. In this paper, a novel approach is put forward to correct bandwidth for an LED spectrum based on a Levenberg–Marquardt algorithm and He–Zheng model. We compare estimation errors of different LED spectra by using the proposed method along with the Richardson–Lucy method and differential operator approach. The experimental results show that the effect of the proposed approach is better than that of the other two methods.