Anja Bathke

Mrs. Anja Bathke

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2022 in Analytical Chemistry
Verified
Journal Article
Open access
SOSaban Oezipek
Saban Oezipek
SHSina Hoelterhoff
Sina Hoelterhoff
SBSimon Breuer
Simon Breuer
CBChristian Bell
Christian Bell
ABAnja Bathke
Anja Bathke
For the past few years, multidimensional liquid chromatography-mass spectrometry (LC-MS) systems have been commonly used to characterize post-translational modifications (PTMs) of therapeutic antibodies (mAbs). In most cases, this is performed by fractionation of charge variants by ion-exchange chromatography and subsequent online LC-MS peptide mapping analysis. In this study, we developed a multidimensional ultra-performance-liquid-chromatography-mass spectrometry system (mD-UPLC-MS/MS) for PTM characterization and quantification, allowing both rapid analysis and decreased risk of artificial modifications during sample preparation. We implemented UPLC columns for peptide mapping analysis, facilitating the linkage between mD-LC and routine LC-MS workflows. Furthermore, the introduced system incorporates a novel in-parallel trypsin and LysC on-column digestion setup, followed by a combined peptide mapping analysis. This parallel digestion with different enzymes enhances characterization by generating two distinct peptides. Using this approach, a low retentive ethylene oxide adduct of a bispecific antibody was successfully characterized within this study. In summary, our approach allows versatile and rapid analysis of PTMs, enabling efficient characterization of therapeutic molecules.

1 July 2020 in Journal of Chromatography B
Verified
Journal Article
Closed access
LBLudwig Gerhard Bauer
Ludwig Gerhard Bauer
SHSina Hoelterhoff
Sina Hoelterhoff
TGTobias Graf
Tobias Graf
CBChristian Bell
Christian Bell
ABAnja Bathke
Anja Bathke

12 March 2025 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
KHKatrin Heinrich
Katrin Heinrich
SHSina Hoelterhoff
Sina Hoelterhoff
SOSaban Oezipek
Saban Oezipek
MWMartin Georg Winter
Martin Georg Winter
TRTobias Rainer
Tobias Rainer
ABAnja Bathke
Anja Bathke
Background/Objectives: Multi-dimensional liquid chromatography coupled with mass spectrometry (mD-LC-MS) has emerged as a powerful technique for the in-depth characterization of biopharmaceuticals by assessing chromatographically resolved product variants in a streamlined and semi-automated manner. The study aims to demystify and enhance the accessibility to this powerful but inherently complex technique by detailing a robust and user-friendly instrument platform, allowing analysts to switch seamlessly between intact, subunit, and peptide mapping workflows. Methods: Starting from a commercially available Two-Dimensional Liquid Chromatography (2D-LC) system, we introduce specific hardware and software extensions leading to two versatile mD-LC-MS setups, in slightly different configurations. The technique’s efficacy is demonstrated through a case study on a cation exchange chromatography method assessing the charge variants of a bispecific antibody, isolating peak(s) of interest, followed by online sample processing, including reduction and enzymatic digestion, and subsequently mass spectrometry analysis. Results: The accuracy and reproducibility of both mD-LC-MS setups proposed in this study were successfully tested. Despite the complex peak patterns in the first dimension, the systems were equally effective in identifying and quantifying the underlying product species. This case study highlights the routine usability of mD-LC-MS technology for the characterization of (ultra) high-performance liquid chromatography (UHPLC) of therapeutic biomolecule. Conclusions: The demonstrated reliability and accuracy underscore the practicality of mD-LC-MS for routine use in biopharmaceutical analysis. Our detailed description of the mD-LC-MS systems and insights simplify access to this advanced technology for a broader scientific community, regardless of expertise level, and lower the entry barrier for its use in various research and industrial settings.

27 January 2023 in Journal of Chromatography B
Verified
Journal Article
Open access
SHSina Hoelterhoff
Sina Hoelterhoff
JWJan Wendler
Jan Wendler
LALiya Arackal
Liya Arackal
BFBenjamin Felkel
Benjamin Felkel
CBChristian H. Bell
Christian H. Bell
ABAnja Bathke
Anja Bathke
Surfactant degradation in biopharmaceuticals has recently gained significant attention in the pharmaceutical industry. Specifically, hydrolytic degradation of polysorbates, leading to the release of free fatty acids potentially forming visible particles, is a key theme in technical development. To address this emerging topic, we present the development of a fully automated liquid-chromatography single quad mass detector method for the quantification of free fatty acids in biopharmaceuticals. For the first time, we have quantified the longer chain fatty acid degradation products of polysorbate, palmitic and stearic acid, allowing reliable detection and early critical insights for process improvements. This high-throughput method was validated underlining its robust performance in an interlaboratory trial as well as high flexibility allowing different robotic platforms and preparation techniques. The combination of automated sample preparation, separation by liquid chromatography and single quad mass detection makes the validated fatty acid mass spectrometry assay ready for routine use in a regulated environment.

11 September 2026 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
ZHZhiqi Hao
Zhiqi Hao
CYChristopher Yu
Christopher Yu
ABAnja Bathke
Anja Bathke
JYJack Yim
Jack Yim
ABAlexander Buettner
Alexander Buettner
YYYi Yang
Yi Yang
The increasing complexity of modern protein therapeutics and the demand for faster development of new therapeutics require not only advanced analytical tools that provide in-depth understanding of the product quality attributes (PQAs) that are crucial for safety and efficacy but also the implementation of a control strategy to ensure that the released drug product meets the desired quality profile. The multi-attribute method (MAM), a liquid chromatography–mass spectrometry (LC-MS) approach, has emerged as a transformative solution that provides site-specific monitoring of multiple critical quality attributes (CQAs) in a single workflow, replacing several conventional profile-based assays. The MAM achieves comprehensive quality oversight through two primary mechanisms: targeted attribute quantitation (TAQ) for the simultaneous quantification of predefined known modifications, and new peak detection (NPD) for identifying unforeseen impurities, thereby establishing a robust, “double-layered” control strategy. This article reviews the practical challenges and current industry practices for successfully implementing the MAM within current good manufacturing practice (cGMP) environments. The successful transition of the MAM from a specialized characterization tool to a validated quality control (QC) cornerstone relies on a framework built upon four foundational pillars: stringent instrument qualification paired with compliance-ready informatics, proactive and strictly scheduled instrument maintenance, rigorous system suitability testing (SST), and phase-appropriate method validation and transfer. The challenges of global method transfer and the solutions to mitigate inter-laboratory variability are discussed. Finally, the review explores the emerging trends shaping the future of the MAM in QC and the critical role of the MAM in facilitating real-time release testing (RTRT) in next-generation autonomous manufacturing.

7 September 2024 in Methods and Protocols
Verified
Journal Article
Open access
PDF file
ABAnja Bathke
Anja Bathke
SHSina Hoelterhoff
Sina Hoelterhoff
JWJan Wendler
Jan Wendler
IYInn Yuk
Inn Yuk
CBChristian H. Bell
Christian H. Bell
Polysorbates are the predominant surfactants used to stabilize protein formulations. Unfortunately, polysorbates can undergo hydrolytic degradation, which releases fatty acids that can accumulate to form visible particles. The detection and quantitation of these fatty acid degradation products are critical for assessing the extent of polysorbate degradation and the associated risks of particle formation. We previously developed a user-friendly mass spectrometric method called Fatty Acids by Mass Spectrometry (FAMS) to quantify the free fatty acids. The FAMS method was validated according to ICH Q2 (R1) guidelines and is suitable for a wide range of products, buffers and protein concentrations. The end-to-end workflow can be automated from sample preparation to data analysis. To broaden method accessibility, the QDa detector selected for fatty acid measurement does not require specific mass spectrometry experience. We provide here a detailed procedure for both manual and automated sample preparation for high-throughput analysis. In addition, we highlight in this protocol the critical operational details, procedural watchouts and troubleshooting tips to support the successful execution of this method in another laboratory.