Thermography from unmanned aerial vehicles (UAV) is widely used for module condition surveys and defect detection in solar (photovoltaic) power plants. This article presents an optimized defect inspection procedure in which a two-stage autonomous flight strategy is adopted to reduce the operation time, and thereby the cost. The first stage is a fast high-altitude flight for rapid coverage of the entire plant. The resolution on the modules is then somewhat degraded, but adequate for detection of possible defect locations. In the second stage, an optimized flight path is calculated to revisit and image only the detected locations from a lower altitude, where the resolution is sufficient for the classification of defects. This concept is studied through simulations of different plant geometries and defect densities. The simulations are supported by actual data, including a plant-scale survey. The proposed strategy is shown to have the potential for significant savings in operation time, on the order of 60% in the experimental case with 2% module defects. Commonly reported defect densities of 0.5% to 1% will give even larger savings. The inspection strategy is shown to be especially beneficial for plant geometries representative of high latitudes.
The degradation of solar photovoltaic (PV) modules over time, which are aggravated by defects, significantly affects the performance of utility-scale PV parks. This study presents a quantitative assessment of the power loss from module defects and evaluates the cost-effectiveness of replacing defective modules at various stages of degradation. A module test site was established in Norway with six different defects, and continuous thermographic monitoring, combined with light IV measurements and electroluminescence (EL) imaging, provides partial support for further calculations on the long-term effects of the defects. The cumulative module energy loss is calculated over a 25-year park lifespan under both Norwegian and Chilean environmental conditions, with the latter representing higher solar irradiation levels. The energy gain from replacing the defective modules at various stages of degradation is compared to the costs of replacement, both for infant-life failures and mid-life failures. It is likely not beneficial to replace minor infant-life defects of 1% power loss in low-irradiation regions like Norway. For Chilean conditions, it can be cost-effective, but primarily if the module is replaced around mid park life, which gives a larger yield when replaced with a new module. For more severe defects of 10% loss, the replacement gain is above the replacement cost for high-irradiation locations, and replacing the 33% power loss defect is cost-effective for both locations, even when discovered late in the park lifetime. It is primarily beneficial to replace mid-life defects in high-irradiation locations.
As the installed capacity of photovoltaic power plants continues its near exponential growth, cost-efficient operation and maintenance strategies become increasingly crucial. Aerial infrared thermography has enabled fast and robust fault detection in utility-scale PV plants. In this article, we explore two key approaches to improve inspection efficiency: increase the flight altitude and deploy swarms of unmanned aerial vehicles. A larger imaging distance expands the field of view but reduces fault detectability and georeferencing accuracy. In this work, we study the tradeoff between inspection efficiency and data quality for automatic fault detection and localization. The YOLO11 machine learning model was trained to detect defects in thermal images, and its performance was evaluated to vary imaging distances and camera pitch angles. Fault detection remained robust up to approximately 80 m, but georeferencing error became the primary limiting factor. Finally, we conduct a UAV swarm-based inspection of a PV plant, integrating automatic fault detection and localization, and compare the results with ground truth data.
The degradation of solar photovoltaic (PV) modules over time, aggravated by defects, significantly affects the performance of utility-scale PV parks. This study presents a quantitative assessment of the power loss from module defects, and evaluates the cost-effectiveness of replacing defective modules at various stages of degradation. A module test site was established in Norway with six different defects, and continuous thermographic monitoring, combined with light IV measurements and electroluminescence (EL) imaging, provides partial support for further calculations on the long-term effects of the defects. The cumulative module energy loss is calculated over a 25-year park lifespan under both Norwegian and Chilean environmental conditions, the latter representing higher solar irradiation levels. The energy gain from replacing the defective modules at various stages of degradation is compared to the costs of replacement, both for infant-life failures and mid-life failures. Minor infant-life defects of 1\% power loss are likely not beneficial to replace in low-irradiation regions like Norway. For Chilean conditions it can be cost-effective, but primarily if the module is replaced around mid park life, which gives a larger yield when replaced with a new module. For more severe defects of 10\% loss the replacement gain is above the replacement cost for high-irradiation locations, and replacing the 33\% power loss defect is cost-effective for both locations, even when discovered late in the park lifetime. Mid-life defects are primarily beneficial to replace in high-irradiation locations.