Shing Chiu Wong

Dr. Shing Chiu Wong

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2000 in JACC
Verified
Journal Article
Open access
SWShing Chiu Wong
Shing Chiu Wong
TSTimothy Sanborn
Timothy Sanborn
LSLynn A Sleeper
Lynn A Sleeper
JWJohn G Webb
John G Webb
RPRobert Pilchik
Robert Pilchik
JHJudith S Hochman
Judith S Hochman
We sought to delineate the angiographic findings, clinical correlates and in-hospital outcomes in patients with cardiogenic shock (CS) complicating acute myocardial infarction. Patients with CS complicating acute myocardial infarction carry a grave prognosis. Detailed angiographic findings in a large, prospectively identified cohort of patients with CS are currently lacking. We compared the clinical characteristics, angiographic findings, and in-hospital outcomes of 717 patients selected to undergo angiography and 442 not selected, overall and by shock etiology: left or right ventricular failure versus mechanical complications. Patients who underwent angiography had lower baseline risk and a better hemodynamic profile than those who did not. Overall, 15.5% of the patients had significant left main lesions on angiography, and 53.4% had three-vessel disease, with higher rates of both for those with ventricular failure, compared with patients who had mechanical complications. Among patients who underwent angiography, those with ventricular failure had significantly lower in-hospital mortality than patients with mechanical complications (45.2% vs. 57.0%; p = 0.021). Importantly, for patients with ventricular failure, in-hospital mortality also correlated with disease severity: 35.0% for no or single-vessel disease versus 50.8% for three-vessel disease. Furthermore, mortality was associated with the culprit lesion location (78.6% in left main lesion, 69.7% in saphenous vein graft lesions, 42.4% in circumflex lesions, 42.3% in left anterior descending lesions, and 37.4% in right coronary artery lesions), and Thrombolysis In Myocardial Infarction (TIMI) flow grade (46.5% in TIMI 0/1, 49.4% in TIMI 2 and 26% in TIMI 3). Patients who underwent angiographic study in the SHOCK Trial Registry had a more benign cardiac risk profile, more favorable hemodynamic findings and lower in-hospital mortality than those for whom angiograms were not obtained. Patients with CS caused by ventricular failure had more severe atherosclerosis, and a different distribution of culprit vessel involvement but lower in-hospital mortality, than those with mechanical complications. Overall in-hospital survival correlates with the extent of coronary artery obstructions, location of culprit lesion and baseline coronary TIMI flow grade.

1 August 2009 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
SWShing Chiu Wong
Shing Chiu Wong
WBWilliam Bachinsky
William Bachinsky
PCPatrick Cambier
Patrick Cambier
RSRobert Stoler
Robert Stoler
JAJanah Aji
Janah Aji
HWHong Wang
Hong Wang

1 July 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JLJUN LIU
JUN LIU
SASubhi J. Al’aref
Subhi J. Al’aref
GSGurpreet Singh
Gurpreet Singh
ACAlexandre Caprio
Alexandre Caprio
AMAmir Ali Amiri Moghadam
Amir Ali Amiri Moghadam
Bobak MosadeghBobak Mosadegh
Bobak Mosadegh
The primary mode of visualization during transcatheter procedures for structrural heart disease is fluoroscopy, which suffers from low contrast and lacks any depth perception, thus limiting the ability of an interventionalist to position a catheter accurately. This paper describes a new image guidance system by utilizing augmented reality to provide a 3D visual environment and quantitative feedback of the catheter’s position within the heart of the patient. The real-time 3D position of the catheter is acquired via two fluoroscopic images taken at different angles, and a patient-specific 3D heart rendering is produced pre-operatively from a CT scan. The spine acts as a fiduciary land marker, allowing the position and orientation of the catheter within the heart to be fully registered. The automated registration method is based on Fourier transformation, and has a high success rate (100%), low registration error (0.42 mm), and clinically acceptable computational cost (1.22 second). The 3D renderings are displayed and updated on the augmented reality device (i.e., Microsoft HoloLens), which can provide pre-set views of various angles of the heart using voice-command. This new image-guidance system with augmented reality provides a better visualization to interventionalists and potentially assists them in understanding of complicated cases. Furthermore, this system coupled with the developed 3D printed models can serve as a training tool for the next generation of cardiac interventionalists.

1 November 2009 in The American Journal of Cardiology
Verified
Journal Article
Closed access
PDF file
DFDmitriy N. Feldman
Dmitriy N. Feldman
RMRobert M. Minutello
Robert M. Minutello
GBGeoffrey Bergman
Geoffrey Bergman
IMIssam Moussa
Issam Moussa
SWShing Chiu Wong
Shing Chiu Wong

1 November 2005 in The American Journal of Cardiology
Verified
Journal Article
Closed access
SWShing Chiu Wong
Shing Chiu Wong
RMRobert Minutello
Robert Minutello
MHMun K. Hong
Mun K. Hong

6 February 2024 in Journal of the American Heart Association
Verified
Journal Article
Open access
IYIlhwan Yeo
Ilhwan Yeo
RARachel Axman
Rachel Axman
DLDaniel Lu
Daniel Lu
DFDmitriy N. Feldman
Dmitriy N. Feldman
JCJim W. Cheung
Jim W. Cheung
LKLuke K. Kim
Luke K. Kim
Background: Venoarterial extracorporeal membrane oxygenation (VA‐ECMO) is increasingly used for patients with cardiogenic shock. Although Impella or intra‐aortic balloon pump (IABP) is frequently used for left ventricular unloading (LVU) during VA‐ECMO treatment, there are limited data on comparative outcomes. We compared outcomes of Impella and IABP for LVU during VA‐ECMO. Methods and Results: Using the Nationwide Readmissions Database between 2016 and 2020, we analyzed outcomes in 3 groups of patients with cardiogenic shock requiring VA‐ECMO based on LVU strategies: extracorporeal membrane oxygenation (ECMO) only, ECMO with IABP, and ECMO with Impella. Of 15 980 patients on VA‐ECMO, IABP and Impella were used in 19.4% and 16.4%, respectively. The proportion of patients receiving Impella significantly increased from 2016 to 2020 (6.5% versus 25.8%; P ‐trend<0.001). In‐hospital mortality was higher with ECMO with Impella (54.8%) compared with ECMO only (50.4%) and ECMO with IABP (48.4%). After adjustment, ECMO with IABP versus ECMO only was associated with lower in‐hospital mortality (adjusted odds ratio [aOR], 0.83; P =0.02). ECMO with Impella versus ECMO only had similar in‐hospital mortality (aOR, 1.09; P =0.695) but was associated with more bleeding (aOR, 1.21; P =0.007) and more acute kidney injury requiring hemodialysis (aOR, 1.42; P <0.001). ECMO with Impella versus ECMO with IABP was associated with greater risk of acute kidney injury requiring hemodialysis (aOR, 1.49; P =0.002), higher in‐hospital mortality (aOR, 1.32; P =0.001), and higher 40‐day mortality (hazard ratio, 1.25; P <0.001). Conclusions: In patients with cardiogenic shock on VA‐ECMO, LVU with Impella, particularly with 2.5/CP, was not associated with improved survival at 40 days but was associated with increased adverse events compared with IABP. More data are needed to assess Impella platform‐specific comparative outcomes of LVU.