Optofluidic dye lasers integrated into microfluidic chips are promising miniature coherent light sources for biosensing. However, achieving the accurate and efficient tuning of lasers remains challenging. This study introduces a novel pneumatically tunable optofluidic distributed feedback (DFB) dye laser in a multilayer microfluidic chip. The dye laser device integrates microfluidic channels, grating structures, and vacuum chambers. A second-order DFB grating configuration is utilized to ensure single-mode lasing. The application of vacuum pressure to the chambers stretches the soft grating layer, enabling the sensitive tuning of the lasing wavelength at a high resolution of 0.25 nm within a 7.84 nm range. The precise control of pressure and laser tuning is achieved through an electronic regulator. Additionally, the integrated microfluidic channels and optimized waveguide structure facilitate efficient dye excitation, resulting in a low pump threshold of 164 nJ/pulse. This pneumatically tunable optofluidic DFB laser, with its high-resolution wavelength tuning range, offers new possibilities for the development of integrated portable devices for biosensing and spectroscopy.
We demonstrate a two-directional tuning method of distributed feedback (DFB) film dye laser devices to achieve high quality lasing and a large tuning range. In this work, we proposed a simple method to fabricate a continuous tunable solid-state dye laser on a flexible Polydimethylsiloxane (PDMS) film. In order to obtain stable and tunable output lasing, the stretching property of the gelatine host was improved by mixing with a certain ratio of glycerol to prevent DFB cavity destruction. We employed two different tuning strategies of the DFB film dye lasers, by stretching the PDMS film in two perpendicular directions, and a nearly 40 nm tuning range in each direction was achieved. The laser device maintained single mode lasing with 0.12 nm linewidth during the tuning process. The reported tunable DFB film dye laser devices have huge potential as coherent light sources for sensing and spectroscopy applications.
The measurement of cardiac troponin I (cTnI) is of vital importance for the early diagnosis of acute myocardial infarction. In this study, an enhanced electrochemiluminescent immunoassay for the highly sensitive and precise determination of cTnI was reported. A biomimetic chip with nepenthes peristome surface microstructures to achieve single-layer microbead arrays and integrated microelectrode arrays (MEAs) for ECL detection was microfabricated. Ru@SiO2 nanoparticles were prepared as signal amplificators labeling immunomagnetic beads. Dendrimer-encapsulated platinum nanoparticles (Pt DENs) were electrochemically modified on ITO MEAs. The resulting Pt DEN-modified ITO MEAs preserved good optical transparency and exhibited an approximately 20-fold ECL signal amplification compared to that obtained from bare ITO. The method made full use of the biomimetic chip with Pt DENs to develop single-layer immunomagnetic bead arrays with increasingly catalyzed electrochemical oxidation of the [Ru(bpy)3]2+–TPA system. Consequently, a limit of detection calculated as 0.38 pg/mL (S/N = 3) was obtained with excellent selectivity, demonstrating significant potential for the detection of cTnI in clinical diagnostics.
We demonstrated a fiber integrated optofluidic platform to perform miRNA detection with high sensitivity and specificity based on FRET principle. Recently miRNA has attracted extensive interest as a biomarker, providing important evidence for early disease diagnosis and post treatment. Traditionally, numerous analytical approaches such as northern blotting, micro arrays , and real-time quantitative polymerase chain reaction have been developed for miRNA detection. However, the existing methods have many technical challenges, for example, the concentration of miRNA in vivo is normally at low level, and the short sequence and easy degradation by RNAase makes it difficult for PCR. Therefore, we developed an innovative optofluidic platform that combines the advantage of droplet microfluidics and optofluidic technology, and provides a low-cost, compact and high specificity approach for identification and quantification of miRNA using FRET principle. Single-nucleotide differences within miRNA family can be distinguished by a novel Y-junction design of donor, receptor and miRNA sequence. We performed one step miRNA detection with simple device operation, and our platform achieved target miRNA identification at a low concentration and high specificity.