Mohamed Hedi Bedoui

Prof. Mohamed Hedi Bedoui


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
AKAsma Kerkeni
Asma Kerkeni
ABAsma Benabdallah
Asma Benabdallah
AMAntoine Manzanera
Antoine Manzanera
MBMohamed Hedi Bedoui
Mohamed Hedi Bedoui

1 August 2011 in Pattern Recognition
Verified
Journal Article
Closed access
RLR. Lopes
R. Lopes
PDP. Dubois
P. Dubois
IBI. Bhouri
I. Bhouri
MBMohamed Hedi Bedoui
Mohamed Hedi Bedoui
SMS. Maouche
S. Maouche
NBN. Betrouni
N. Betrouni

10 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RMRamzi Mahmoudi
Ramzi Mahmoudi
NBNarjes Benameur
Narjes Benameur
Rania MabroukRania Mabrouk
Rania Mabrouk
Mazin Abed MohammedMazin Abed Mohammed
Mazin Abed Mohammed
Begonya Garcia ZapirainBegonya Garcia Zapirain
Begonya Garcia Zapirain
MBMohamed Hedi Bedoui
Mohamed Hedi Bedoui
Background: Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is a global threat impacting the lives of millions of people worldwide. Automated detection of lung infections from Computed Tomography scans represents an excellent alternative; however, segmenting infected regions from CT slices encounters many challenges. Objective: Developing a diagnosis system based on deep learning techniques to detect and quantify COVID-19 infection and pneumonia screening using CT imaging. Method: Contrast Limited Adaptive Histogram Equalization pre-processing method was used to remove the noise and intensity in homogeneity. Black slices were also removed to crop only the region of interest containing the lungs. A U-net architecture, based on CNN encoder and CNN decoder approaches, is then introduced for a fast and precise image segmentation to obtain the lung and infection segmentation models. For better estimation of skill on unseen data, a fourfold cross-validation as a resampling procedure has been used. A three-layered CNN architecture, with additional fully connected layers followed by a Softmax layer, was used for classification. Lung and infection volumes have been reconstructed to allow volume ratio computing and obtain infection rate. Results: Starting with the 20 CT scan cases, data has been divided into 70% for the training dataset and 30% for the validation dataset. Experimental results demonstrated that the proposed system achieves a dice score of 0.98 and 0.91 for the lung and infection segmentation tasks, respectively, and an accuracy of 0.98 for the classification task. Conclusions: The proposed workflow aimed at obtaining good performances for the different system’s components, and at the same time, dealing with reduced datasets used for training.

28 February 2017 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
SHSalah Hamdi
Salah Hamdi
AAAsma Ben Abdallah
Asma Ben Abdallah
MBMohamed Hedi Bedoui
Mohamed Hedi Bedoui
The sequence of Q, R, and S peaks (QRS) complex detection is a crucial procedure in electrocardiogram (ECG) processing and analysis. We propose a novel approach for QRS complex detection based on the deterministic finite automata with the addition of some constraints. This paper confirms that regular grammar is useful for extracting QRS complexes and interpreting normalized ECG signals. A QRS is assimilated to a pair of adjacent peaks which meet certain criteria of standard deviation and duration. The proposed method was applied on several kinds of ECG signals issued from the standard MIT-BIH arrhythmia database. A total of 48 signals were used. For an input signal, several parameters were determined, such as QRS durations, RR distances, and the peaks’ amplitudes. σRR and σQRS parameters were added to quantify the regularity of RR distances and QRS durations, respectively. The sensitivity rate of the suggested method was 99.74% and the specificity rate was 99.86%. Moreover, the sensitivity and the specificity rates variations according to the Signal-to-Noise Ratio were performed. Regular grammar with the addition of some constraints and deterministic automata proved functional for ECG signals diagnosis. Compared to statistical methods, the use of grammar provides satisfactory and competitive results and indices that are comparable to or even better than those cited in the literature.

1 March 2018 in Microprocessors and Microsystems
Verified
Journal Article
Closed access
MAMehdi Abadi
Mehdi Abadi
Slavisa JovanovicSlavisa Jovanovic
Slavisa Jovanovic
Khaled Ben KhalifaKhaled Ben Khalifa
Khaled Ben Khalifa
Serge WeberSerge Weber
Serge Weber
MBMohamed Hedi Bedoui
Mohamed Hedi Bedoui

1 October 2010 in Pattern Recognition Letters
Verified
Journal Article
Closed access
AAA. Ben Abdallah
A. Ben Abdallah
FGF. Ghorbel
F. Ghorbel
KCK. Chatti
K. Chatti
HEH. Essabbah
H. Essabbah
MBMohamed Hedi Bedoui
Mohamed Hedi Bedoui