Samuel CALLE

Prof. Dr. Samuel CALLE

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2014 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
CTChloé Trarieux
Chloé Trarieux
SCSamuel CALLE
Samuel CALLE
HMHélène Moreschi
Hélène Moreschi
GRGuillaume Renaud
Guillaume Renaud
MDMarielle Defontaine
Marielle Defontaine
Dynamic Acoustoelastic Testing (DAET) has been developed to non-invasively assess the nonlinear viscoelastic properties of fluids and solids. We propose a phenomenologically motivated model for harmonic regime to identify nonlinear viscoelastic parameters from DAET experiments. The nonlinear elastic and viscous parameters are derived from the real and imaginary components of the Taylor series expansion of the complex longitudinal modulus. The model is applied to Newtonian fluids that exhibit classical elastic nonlinearities and glass beads saturated with water that exhibit nonclassical viscoelastic nonlinearities. Hysteresis, asymmetry, and DC offset are well accounted for in the model.

20 May 2021 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
ABAline Banquart
Aline Banquart
SCSamuel CALLE
Samuel CALLE
FLFranck Levassort
Franck Levassort
LFLionel Fritsch
Lionel Fritsch
FOFrédéric Ossant
Frédéric Ossant
JGJean-Marc Grégoire
Jean-Marc Grégoire
We investigated the innovative processing of poly(vinylidene fluoride-trifluoroethylene) P(VDFx-TrFE1-x) (x = 83 mol. %) by inkjet printing to deliver uniform and thickness-controlled layers on silicon substrates. Here, we provide detailed processing steps and optimize film deposition conditions. The thickness coupling factor for a P(VDF-TrFE) film around 11 μm thick was 22%, demonstrating good electromechanical performance after poling. These multilayer structures were specifically for high-frequency, single-element ultrasonic transducer applications. The measurements of electro-acoustic responses were in water. The maximal frequency was centered at 33.2 MHz and had a fine axial resolution at 22 μm, corresponding to a fractional bandwidth at −6 dB of 100%. In the context of technological evolutions aimed at miniaturized devices and integrated electronics, these results allow for the consideration of complex structures such as multi-element transducers for high-frequency imaging applications.

12 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SSSEAN TOFFESSI SIEWE
SEAN TOFFESSI SIEWE
SCSamuel CALLE
Samuel CALLE
FMFrançois Vander Meulen
François Vander Meulen
DVDamien Valente
Damien Valente
JGJean-Marc Grégoire
Jean-Marc Grégoire
FLFranck Levassort
Franck Levassort
Backing materials with tailored acoustic properties are beneficial for miniaturized ultrasonic transducer design. Whereas piezoelectric P(VDF-TrFE) films are common elements in high-frequency (>20 MHz) transducer design, their low coupling coefficient limits their sensitivity. Defining a suitable sensitivity–bandwidth trade-off for miniaturized high-frequency applications requires backings with impedances of >25 MRayl and strongly attenuating to account for miniaturized requirements. The motivation of this work is related to several medical applications such as small animal, skin or eye imaging. Simulations showed that increasing the acoustic impedance of the backing from 4.5 to 25 MRayl increases transducer sensitivity by 5 dB but decreases the bandwidth, which nevertheless remains high enough for the targeted applications. In this paper, porous sintered bronze material with spherically shaped grains, size-adapted for 25–30 MHz frequency, was impregnated with tin or epoxy resin to create multiphasic metallic backings. Microstructural characterizations of these new multiphasic composites showed that impregnation was incomplete and that a third air phase was present. The selected composites, sintered bronze–tin–air and sintered bronze–epoxy–air, at 5–35 MHz characterization, produced attenuation coefficients of 1.2 and >4 dB/mm/MHz and impedances of 32.4 and 26.4 MRayl, respectively. High-impedance composites were adopted as backing (thickness = 2 mm) to fabricate focused single-element P(VDF-TrFE)-based transducers (focal distance = 14 mm). The center frequency was 27 MHz, while the bandwidth at −6 dB was 65% for the sintered-bronze–tin–air-based transducer. We evaluated imaging performance using a pulse-echo system on a tungsten wire (diameter = 25 μm) phantom. Images confirmed the viability of integrating these backings in miniaturized transducers for imaging applications.

31 January 2017 in Journal of Obstetrics and Gynaecology
Verified
Journal Article
Closed access
CDCaroline Diguisto
Caroline Diguisto
ESEmmanuel G. Simon
Emmanuel G. Simon
SCSamuel CALLE
Samuel CALLE
RTRedouane Ternifi
Redouane Ternifi
JRJean-Pierre Remeniéras
Jean-Pierre Remeniéras
FPFranck Perrotin
Franck Perrotin

1 February 2013 in Advances in Applied Ceramics: Structural, Functional and Bioceramics
Verified
Journal Article
Closed access
EFE Filoux
E Filoux
RLR Lou-Moeller
R Lou-Moeller
SCSamuel CALLE
Samuel CALLE
MLMarc Lethiecq
Marc Lethiecq
FLFranck Levassort
Franck Levassort

24 June 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MRMatthieu RENAUD
Matthieu RENAUD
MGMickael Gette
Mickael Gette
ADAlexis Delpierre
Alexis Delpierre
SCSamuel CALLE
Samuel CALLE
FLFranck Levassort
Franck Levassort
Gael Y. ROCHEFORTGael Y. ROCHEFORT
Gael Y. ROCHEFORT
Introduction: Periodontal disease is an infectious syndrome presenting inflammatory aspects. Radiographic evaluation is an essential complement to clinical assessment but has limitations such as the impossibility of assessing tissue inflammation. It seems essential to consider new exploration methods in clinical practice. Ultrasound of periodontal tissues could make it possible to visualize periodontal structures and detect periodontal diseases (periodontal pocket measurement and the presence of intra-tissue inflammation). Clinical Innovation Report: An ultrasound probe has been specially developed to explore periodontal tissues. The objective of this clinical innovation report is to present this device and expose its potential. Discussion: Various immediate advantages favor using ultrasound: no pain, no bleeding, faster execution time, and an image recording that can be replayed without having to probe the patient again. Ultrasound measurements of pocket depth appear to be as reliable and reproducible as those obtained by manual probing, as do tissue thickness measurements and the detection of intra-tissue inflammation. Conclusions: Ultrasound seems to have a broad spectrum of indications. Given the major advances offered by ultrasound imaging as a complementary aid to diagnosis, additional studies are necessary to validate these elements and clarify the potential field of application of ultrasound imaging in dentistry.