The advent of nanotechnology has motivated a revolution in the development of miniaturized sensors. Such sensors can be used for radiation detection, temperature sensing, radio-frequency sensing, strain sensing, and more. At the nanoscale, integrating the materials of interest into sensing platforms can be a common issue. One promising platform is photonic crystal fibers, which can draw in optically sensitive nanoparticles or have its optical properties changed by specialized nanomaterials. However, testing these sensors at scale is limited by the the need for specialized equipment to integrate these photonic crystal fibers into optical fiber systems. Having a method to enable rapid prototyping of new nanoparticle-based sensors in photonic crystal fibers would open up the field to a wider range of laboratories that could not have initially studied these materials in such a way before. This manuscript discusses the improved processes for cleaving, drawing, and rapidly integrating nanoparticle-based photonic crystal fibers into optical system setups. The method proposed in this manuscript achieved the following innovations: cleaving at a quality needed for nanoparticle integration could be done more reliably (≈100% acceptable cleaving yield versus ≈50% conventionally), nanoparticles could be drawn at scale through photonic crystal fibers in a safe manner (a method to draw multiple photonic crystal fibers at scale versus one fiber at a time), and the new photonic crystal fiber mount was able to be finely adjusted when increasing the optical coupling before inserting it into an optical system (before, expensive fusion splicing was the only other method).
Legacy high powered electric field measurement devices, such as flush plate dipoles (D-dots) and waveguides, are the primary diagnostic tools used for free-field experimentation. Unfortunately, these metallic devices perturb the electric field of interest via scattering and require the use of coaxial cables (fluctuates with temperature). Electro-optic (EO) probes offer a potential solution as they minimally perturb the electric field and fiber optic cables can be designed to correct out or prevent temperature fluctuations. However, to replace the legacy diagnostics, it is critical that the EO probes are calibrated in field relevant conditions (outdoor temperatures between 1.4°C-49°C). Characterization of a modern EO sensor is done by using an environmental chamber and a gigahertz transverse electromagnetic (GTEM) cell. The collected data in this paper indicates that modern LiNbO 3 EO sensors have linear changes across both various temperatures and electric fields. This paper outlines the process of creating field relevant conditions in the laboratory settings. Because temperature effects are ubiquitous with most devices, the temperature response of the EO probe needed to be isolated from all other temperature effects. Using a novel way in applying the design of experiments (DoE) method, the temperature response of the EO probe can be isolated and a linear trend can be resolved. The data suggests that the EO probe under test can be used to measure RF fields as long as a small correction factor is applied of 0.52% per °C for every °C away from 22.0°C in either direction.
Characterizing new electric field (E-field) sensors requires knowing the frequency limits of one’s radio frequency (RF) chamber. A commonly used RF chamber is called a gigahertz transverse-electromagnetic (GTEM) cell which supports transverse-electromagnetic fields through the gigahertz spectra. This manuscript proposes a new methodology in determining the range of usable frequencies within a GTEM cell having unknown characteristics (e.g. after moving a GTEM cell from one laboratory to another). Above a certain frequency, all frequencies become overmoded and yield unreliable measurements. We found that comparing international standards to measured data can provide insight to where overmoding occurs. The comparison to international standards was assisted by a derived free-space wave impedance formula in the frequency domain using both flush-plate dipole (D-dot) and magnetic field (B-dot) probes. Overall, this paper proposes a new tool for determining the operating frequencies at which GTEM cells can reliably function in accordance to international standards before overmoding occurs.
Magnetite nanocrystals show promise for electrically small gigahertz frequency applications, which could lead to miniaturizing transformer cores and new sensing technologies. This work presents a rigorous radiofrequency characterization of these nanocrystals using vector network analyzer (VNA) ferromagnetic resonance (FMR) measurements. For the first time, two different average diameters of Fe3O4 nanocrystals are investigated (7.3 and 20.2 nm). When the VNA-FMR results were compared to micromagnetic simulations, the magnetic anisotropy (K-1) deviated from the ideal mean orientation value of K-1/2 to K-1/80 for the 7.3 nm nanocrystal. In contrast, the obtained magnetic anisotropy in 20.2 nm nanocrystals slightly deviated to K-1/11 due to less structural deformations. These findings resulted in a newly proposed methodology for an approximate simulation based on VNA-FMR measurements. In addition, this work estimates the approximate amount of nanocrystals needed to measure a useful VNA-FMR spectrum.
Pulsed power applications face limitations in pushing gyromagnetic nonlinear transmission lines (NLTLs) to higher frequencies (≥3 GHz) and efficiencies (>10%). This study investigates the use of superparamagnetic (SPM) magnetite nanocrystals incorporated into dielectric micropowders for potential use in NLTLs. We report the observation of unexpected high-frequency mesoband formations up to 10 GHz in novel ferrous nanocomposites designed for nonlinear transmission lines (NLTLs). Typically, NLTLs generate well below 10 GHz. The generation of these high frequencies could have use in intentional electromagnetic interference (IEMI) for stress testing of electrical systems, radio detection and ranging, and multi-frequency probing for subsurface imaging. At higher dielectric loading, it was observed that the ferromagnetic resonance spectrum was oscillatory and could not be explained by the Landau-Lifshitz-Gilbert equation. Instead, it is proposed that the unique mixture of magnetic nanocrystals with dielectric microparticles could be exhibiting a complex magnetic response. The measurement methodologies developed during this study and the new response mechanism could be of use for researchers and engineers in the future development of gyromagnetic NLTLs.