Ignazio Vilardi

Dr. Ignazio Vilardi

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2022 in Environments
Verified
Journal Article
Open access
PDF file
Alessandro RizzoAlessandro Rizzo
Alessandro Rizzo
GAGiuseppe Antonacci
Giuseppe Antonacci
EBEnrico Borra
Enrico Borra
FCFrancesco Cardellini
Francesco Cardellini
Luca CicianiLuca Ciciani
Luca Ciciani
IVIgnazio Vilardi
Ignazio Vilardi
Gamma emitting radionuclides naturally present in the Earth’s crust and the radon exhaled by soil in the atmosphere with its short-lived progeny are two of the main contributors to the environmental gamma dose rate that typically characterizes an outdoor measurement site. The present work aims to investigate variations in the environmental dose-rate time series originated by different natural phenomena, such as weather and seismic events, which can modify the radon concentration in the air. The data analyzed here were acquired over a five-year period using a Reuter–Stokes high-pressure ionization chamber placed in the ENEA Casaccia Research Center (Rome, Italy), from November 2013 to December 2018. The detector was set to take a single measurement of the equivalent ambient dose H*(10) every 15 min, thereby collecting more than 184,000 values over the five-year period under consideration. The detector’s sensitivity to the short-lived radon progeny was verified in a preparatory study performed by means of simultaneous radon flux measurement on field. Variations induced by meteorological events as well as variations potentially induced by seismic events were investigated by implementing different data analysis techniques. In the latter case, a retrospective preliminary study was conducted, applying the ARFIMA class of models in order to test the method’s potential. The analysis techniques, results and potential applications are presented and discussed in this article.

10 November 2023 in The European Physical Journal Plus
Verified
Journal Article
Open access
PDF file
Alessandro RizzoAlessandro Rizzo
Alessandro Rizzo
EBEnrico Maria Borra
Enrico Maria Borra
Luca CicianiLuca Ciciani
Luca Ciciani
LFLuca Di Fino
Luca Di Fino
GRGiulia Romoli
Giulia Romoli
LNLivio Narici
Livio Narici
Future manned missions in deep space toward Moon and Mars represent one of the greatest challenges for radiological protection, which task is to mitigate risks for human life raised by the hostile space radiation environment. The prolonged exposure of astronauts to cosmic rays, mainly ion fields of galactic or solar origin, with a large dynamical behavior in time and space with a wide range of kinetic energies, may result in an unacceptable life risk for the next deep space manned missions. Indeed, these ions can deliver significant doses to astronauts by directly hitting human tissues as well as exposing them to secondary particles (neutron and high-LET nuclear fragments) produced by their interaction with space habitat materials. This radiation environment is very different from work environments on Earth, for example, in nuclear power plants or nuclear medicine departments, for which radioprotection was historically developed. Workers on Earth are mainly exposed to photons ( $$\textrm{X}$$ X -rays and $$\gamma$$ γ -rays), to $$\alpha$$ α - and $$\beta$$ β -particles and neutrons, with lower energies than those in space. This difference marks a significant change in the methodological approach of the radioprotection in space compared to that on ground. The review presents the basic principles of radiation protection in space compared to that on ground and the strategies that must be implemented to mitigate risks in manned missions. In particular, the principles of the integrated multidisciplinary approach proposed by NASA and other space agencies for human space exploration are also discussed, with emphasis on the synergies among the various countermeasures proposed.

1 October 2019 in Radiation Measurements
Verified
Journal Article
Closed access
ALA.L. Lebacq
A.L. Lebacq
MSM.A. Saizu
M.A. Saizu
MTM. Takahashi
M. Takahashi
MIM. Isaksson
M. Isaksson
BBB. Bravo
B. Bravo
DBDavid Broggio
David Broggio

6 November 2018 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
IVIgnazio Vilardi
Ignazio Vilardi
GAGiuseppe Antonacci
Giuseppe Antonacci
PBPaolo Battisti
Paolo Battisti
SBSandro Bortoluzzi
Sandro Bortoluzzi
CCCarlo-Maria Castellani
Carlo-Maria Castellani
SZSalvatore Zicari
Salvatore Zicari
In order to properly respond to an emergency caused by an accident in a nuclear power plant with a spread of radionuclides in the atmosphere, we propose a field procedure to perform a large-scale individual thyroid monitoring of internal contamination due to inhalation of 131 I, by means of non-spectrometric equipment, in particular dose rate meters. Specific attention is paid to the individual monitoring of children, because of the very high radiosensitivity of the child’s thyroid to the carcinogenic effects of ionising radiation. The device performance was evaluated by measuring mock iodine sources provided in the Child and Adult Thyroid Monitoring After Reactor Accident (CAThyMARA) intercomparison and, just for a scintillator dose rate meter, by means of 60 s acquisitions of healthy volunteers’ thyroids. All the devices showed a remarkable accuracy in quantification of equivalent 131 I activity in the thyroids of persons of all ages. The selected scintillator dose rate meter showed detection limit values resulting in a maximum committed equivalent dose to thyroid H T , assuming an acute 131 I inhalation occurred five days before the measurement, equal to 10 mSv (related to five-year-old children). Considering the level of H T values associated with the calculated detection limit activities, the proposed procedure has a significant sensitivity to be used for fast internally thyroid monitoring in nuclear or radiological emergencies, allowing daily monitoring a large amount of individuals.

17 December 2019 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
IVIgnazio Vilardi
Ignazio Vilardi
GAGiuseppe Antonacci
Giuseppe Antonacci
PBPaolo Battisti
Paolo Battisti
CCCarlo-Maria Castellani
Carlo-Maria Castellani
LCLuca Ciciani
Luca Ciciani
LSLuciano Sperandio
Luciano Sperandio
The results obtained in a measurement campaign concerning internal contamination by the gamma-emitting radionuclides of a large number of individuals are presented in this work. The aim is to assess the effectiveness of the spectrometric method in an emergency response following a nuclear power plant accident or a spread of radionuclides in the atmosphere due to an act of terrorism. An HPGe portable spectrometer, deployed in a collective protection apparatus, was used for both whole-body and thyroid measurements. An adult bottle mannequin absorption (BOMAB) and thyroid phantoms were used to evaluate the detector performance. The BOMAB phantom was provided by the Italian Institute of Ionizing Radiation Metrology (INMRI) for the ENEA intercomparison exercise. Thyroid phantoms were provided by the Belgian Nuclear Research Centre for the ‘Child and Adult Thyroid Monitoring After Reactor Accident’ European intercomparison exercise. The instrument performance was further evaluated by collecting spectral data from healthy volunteers, using acquisition times of 180 s and 100 s, respectively, for the whole-body and thyroid measurements. The detector showed good accuracy in quantifying radionuclide activities in the adult BOMAB and in the thyroids of persons of all ages. The proposed method allows us to detect in vivo activity leading to a committed effective dose E (50) and committed thyroid equivalent doses H T greater than 2 mSv due to all gamma-emitting fission products, if the scan is performed within five days after intake. Assuming, for instance, an acute inhalation of 137 Cs and 131 I, the obtained detection limit values for adults lead to a E (50) value equal to 0.08 mSv and an H T value of 0.27 mSv. The E (50) and H T values show that the proposed method can be successfully used when the dose assessment must be rapidly performed for a large number of individuals in the eventuality of the scenarios previously mentioned.

16 November 2023 in The European Physical Journal Plus
Verified
Journal Article
Open access
PDF file
LSLuciano Sperandio
Luciano Sperandio
Luigi LeporeLuigi Lepore
Luigi Lepore
EBEnrico Maria Borra
Enrico Maria Borra
Luca CicianiLuca Ciciani
Luca Ciciani
VFValentina Fabrizio
Valentina Fabrizio
IVIgnazio Vilardi
Ignazio Vilardi
The nuclear facility TRIGA RC-1 is located at the ENEA Casaccia Research Center in Rome. It is a thermal spectrum research reactor with a thermal power of 1 MW and a Mark III containment. The failure of the fuel cladding of the General Atomic TRIGA is a well-known phenomenon in the literature and is normally expected during its lifetime. Depending on the severity of the cracking, this results in the transfer of radioactivity from inside the fuel rods to the demineralized moderation and cooling water of the primary circuit. This occurs especially when the fuel is heated, as the temperature rise leads to an increase in the internal pressure inside the rods, causing fission products, especially gaseous ones, to be released through the cracks. The sustained release of these fission products over time causes impurities with longer half-lives (e.g., Cs-137) to accumulate in the primary water purification system and, in particular, in the ion exchange resin tank. Therefore, the detection of Cs-137 in the ion exchange resins of the primary water purification system of the reactor is a sufficiently clear indication of the occurrence of such disturbances. Indeed, Cs-137 is not only a direct fission product of U-235, but is also produced by the decay of Xe-137 (one of the major fission noble gasses), which, because of its physical nature, readily escapes through the rod cladding. To ensure worker protection from ionizing radiation during the identification and replacement of defective fuel rods, a special program of physical, environmental, and personal radiation protection monitoring was conducted. In addition to a brief description of the work performed, this report presents the results of radiometric measurements and associated individual dose assessment performed before, during, and after the identification and replacement of the defected fuel elements.