Michela Salvatici

Dr. Michela Salvatici

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
SGSonia Gioffré
Sonia Gioffré
MCMattia Chiesa
Mattia Chiesa
DCDaniela Cardinale
Daniela Cardinale
VRVeronica Ricci
Veronica Ricci
CVChiara Vavassori
Chiara Vavassori
YDYuri D'Alessandra
Yuri D'Alessandra
Anthracyclines are anti-neoplastic drugs presenting cardiotoxicity as a side effect. Cardiac troponins (cTn) and echocardiography are currently used to assess cardiac damage and dysfunction, but early biomarkers identifying patients in need of preventive treatments remain a partially met need. Circulating microRNAs (miRNAs) represent good candidates, so we investigated their possible roles as predictors of troponin elevation upon anthracycline treatment. Eighty-eight female breast cancer patients administered with doxorubicin (DOX) or epirubicin (EPI) were divided into four groups basing on drug type and cTn positive (cTn+) or negative (cTn−) levels: DOX cTn−, DOX cTn+, EPI cTn− and EPI cTn+. Blood was collected at baseline, during treatment, and at follow-up. We identified plasma miRNAs of interest by OpenArray screening and single assay validation. Our results showed miR-122-5p, miR-499a-5p and miR-885-5p dysregulation in DOX patients at T0, identifying a signature separating, with good accuracy, DOX cTn− from DOX cTn+. No miRNAs showed differential expression in EPI subjects. Conversely, an anthracycline-mediated modulation (regardless of cTn) was observed for miR-34a-5p, -122-5p and -885-5p. Our study indicates specific circulating miRNAs as possible prediction markers for cardiac troponin perturbation upon anthracycline treatment. Indeed, our findings hint at the possible future use of plasma miRNAs to predict the cardiac responsiveness of patients to different anticancer agents.

16 November 2020 in Biomarkers
Verified
Journal Article
Closed access
MSMichela Salvatici
Michela Salvatici
BBBarbara Barbieri
Barbara Barbieri
SCSara Maria Giulia Cioffi
Sara Maria Giulia Cioffi
EMEmanuela Morenghi
Emanuela Morenghi
FLFrancesco Paolo Leone
Francesco Paolo Leone
MSMaria Teresa Sandri
Maria Teresa Sandri
Severe pneumonia is pathological manifestation of Coronavirus Disease 2019 (COVID-19), however complications have been reported in COVID-19 patients with a worst prognosis. Aim of this study was to...

Verified
Journal Article
Open access
PDF file
MSMichela Salvatici
Michela Salvatici
CSCarmen Sommese
Carmen Sommese
Massimiliano Marco Corsi RomanelliMassimiliano Marco Corsi Romanelli
Massimiliano Marco Corsi Romanelli
Lorenzo DragoLorenzo Drago
Lorenzo Drago
Heterophile antibodies are immunoglobulins produced by the immune system in response to exposure to animal and bacterial antigens, blood transfusions, autoimmune disorders, hematologic malignancies, dialysis, and pregnancy. Recently, these antibodies have garnered significant attention due to their impact on the accuracy of laboratory test results. Heterophile antibodies can bind not only to specific antigens but also to those from different species, including the antibodies used in laboratory tests. This cross-reactivity with foreign proteins is the basis for their interference in immunological assays, such as those measuring cardiospecific troponins (cTn). This manuscript reviews the literature on cases of heterophile antibody interference in troponin testing and proposes an algorithm for identifying such interference when clinical discrepancies arise. Recognizing and addressing heterophile antibody interference is crucial, particularly for tests like those for troponins, which are key biomarkers in the diagnosis and management of emergency and intensive care patients. The literature emphasizes the need for accurate procedures to distinguish true cardiac damage from false positives, thereby preventing unnecessary additional tests and hospitalizations.

Verified
Journal Article
Open access
PDF file
FRFrancesca De Rino
Francesca De Rino
FRFrancesca Rispoli
Francesca Rispoli
MZMarta Zuffi
Marta Zuffi
EMEleonora Matteucci
Eleonora Matteucci
AGArmando Gavazzi
Armando Gavazzi
Lorenzo DragoLorenzo Drago
Lorenzo Drago
Neuropsychological interviews and neuroimaging techniques are traditional diagnostic methods for Alzheimer’s disease (AD). However, the development of blood-based biomarkers, such as Amyloid beta (Aβ), phosphorylated Tau (pTau), and their ratios, offers promising non-invasive alternatives for early AD detection. This study aimed to analyze the correlation between CSF and plasma biomarkers (Aβ40, Aβ42, Aβ42/Aβ40, pTau181) and evaluate their diagnostic performance in 51 patients with cognitive impairments. Biomarkers were analyzed in both plasma and CSF using an automated chemiluminescence enzyme immunoassay, Lumipulse (Fujirebio). The results showed significant positive correlations between CSF and plasma levels of Aβ42, the Aβ42/Aβ40 ratio, and pTau181, but not for Aβ40. Plasma Aβ42, pTau181, Aβ42/Aβ40 ratio, and pTau181/Aβ42 ratio demonstrated significant differences between patients A+ vs. A− classified based on CSF Amyloid status, as well as between those classified as A+T+ and A−T− according to both CSF Amyloid and Tau levels. Plasma pTau181, Aβ42/Aβ40, and pTau181/Aβ42 ratio showed high diagnostic accuracy in distinguishing A+ from A− (AUC = 0.93–0.95) and A+T+ from A−T− patients (AUC = 0.93–0.97). These findings suggest that plasma biomarkers can effectively differentiate between AD and other forms of dementia, and serve as a reliable, non-invasive tool for early detection and monitoring of Alzheimer’s disease.

Verified
Journal Article
Open access
PDF file
MSMichela Salvatici
Michela Salvatici
MGMonica Gaimarri
Monica Gaimarri
FRFrancesca Rispoli
Francesca Rispoli
BBBarbara Bianchi
Barbara Bianchi
DSDelia Francesca Sansico
Delia Francesca Sansico
Lorenzo DragoLorenzo Drago
Lorenzo Drago
Heterophile antibodies, which can arise from infections, autoimmune disorders, or exposure to animal antigens, can interfere with immunoassays. These antibodies can cross-react with the test reagents used in troponin assays, causing a false elevation in troponin levels. The paper describes a case of a 37-year-old male drug abuser admitted to the emergency room with chest pain. A series of troponin measurements performed using different assays gave discrepant results. Only thanks to the use of Scantibodies HBT tubes, which remove heterophile antibodies, was it possible to make a correct diagnosis of troponin negativity. In conclusion, a correct laboratory/clinical approach to the identification of heterophile antibody interference is essential for accurate troponin testing in order to avoid false positive results. Implementing neutralizing tests can significantly improve the reliability of these diagnostic assays, ensuring better patient outcome.

Verified
Journal Article
Open access
PDF file
MSMichela Salvatici
Michela Salvatici
CCCecilia Caslini
Cecilia Caslini
SASimona Alesci
Simona Alesci
GAGrazia Arosio
Grazia Arosio
GMGiuliana Meroni
Giuliana Meroni
Lorenzo DragoLorenzo Drago
Lorenzo Drago
Haemoglobin disorders represent a heterogeneous group of inherited conditions that involve at least one genetic abnormality in one or more of the globin chains, resulting in changes in the structure, function, and/or amount of haemoglobin molecules, which are very important for their related clinical aspects. Detecting and characterizing these disorders depends primarily on laboratory methods that employ traditional approaches and, when necessary, newer methodologies essential for solving a number of diagnostic challenges. This review provides an overview of key laboratory techniques in the diagnosis of haemoglobinopathies, focusing on the challenges, advancements, and future directions in this field. Moreover, many haemoglobinopathies are benign and clinically silent, but it is not uncommon to find unexpected variants during routine laboratory tests. The present work reported a rare and clinically interesting case of identification of haemoglobin fractions in an adult man by the determination of glycated haemoglobin (HbA1c) during a routine laboratory assessment, highlighting how the correct use of laboratory data can modify and improve the patient’s clinical management.