Monica Bianchi

Dr. Monica Bianchi


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NLNicola Lambri
Nicola Lambri
CZCaterina Zaccone
Caterina Zaccone
MBMonica Bianchi
Monica Bianchi
ABAndrea Bresolin
Andrea Bresolin
DDDamiano Dei
Damiano Dei
PMPietro Mancosu
Pietro Mancosu
Patient-specific quality assurance (PSQA) procedures ensure the safe delivery of volumetric modulated arc therapy (VMAT) plans. PSQA requires extensive time and resources and may cause treatment delays if replanning is needed due to failures. Recently, our group developed a machine learning (ML) model predicting gamma passing rate (GPR) for VMAT arcs. This study explores automatable replanning strategies for plans identified at risk of failure, aiming to improve deliverability while maintaining dosimetric quality. Between 2022 and 2023, our ML model analyzed 1252 VMAT plans. Ten patients having a predicted GPR (pGPR) <95% were selected. Replanning strategies consisted of limiting monitor units (MUlimit) and employing the aperture shape controller (ASC) tool. Re-optimized plans were compared with the originals in terms of dose volume constraints (DVCs) for the target and organs-at-risk (OARs), and deliverability using the modulation complexity score (MCS), pGPR, and measured GPR (mGPR). Forty-five re-optimizations were performed. Replanning led to an increase in DVCs for OARs and a reduction for the target. Complexity decreased, reflected by the increase in the MCS from 0.17 to 0.21 (MUlimit) and 0.20 (ASC). The deliverability improved, with the pGPR increasing from 93.3% to 94.4% (MUlimit) and 95.1% (ASC), and the mGPR from 99.3% to 99.7% (MUlimit) and 99.8% (ASC). Limiting the MUs or utilizing the ASC reduced the complexity of plans and improved the GPR without compromising the dosimetric quality. These strategies can be used to automate replanning procedures, reduce the workload related to PSQA, and improve patient safety.

6 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MBMonica Bianchi
Monica Bianchi
NLNicola Lambri
Nicola Lambri
DLDaniele Loiacono
Daniele Loiacono
STStefano Tomatis
Stefano Tomatis
MSMarta Scorsetti
Marta Scorsetti
PMPietro Mancosu
Pietro Mancosu
Computed tomography (CT) images are stored at a 12-bit depth. However, many deep learning libraries and pre-trained models are designed for 8-bit images, requiring an intermediate compression step before restoring the original 12-bit physical range. This process causes information loss and can compromise image reliability. This study investigated the impact of two CT resampling methods (8-bit compression; 12-bit decompression) on dose calculation and image quality. Ten total marrow and lymphoid irradiation patients were selected. CT scans were resampled using linear and non-linear look-up tables (l_LUT/nl_LUT). Original and resampled CTs were evaluated considering: (i) Hounsfield unit (HU) root mean squared error (RMSE); (ii) dose-volume histogram (DVH) statistics for target volume and several organs; (iii) 3D gamma passing rate (GPR) with a 1%/1.25 mm criterion; (iv) lymph nodes contouring and diagnostic quality (scale 1–5). The RMSE for l_LUT vs. nl_LUT was 7 ± 1 vs. 10 ± 1 HU. Maximum differences in DVH statistics were 0.4%, with a 3D-GPR = 100% for all cases. CTs resampled with l_LUT exhibited evident brain pixelation (score = 1), whereas nl_LUT matched the original CT quality (score = 4). Both LUTs were acceptable for lymph nodes delineation. The nl_LUT optimized the CT resampling process, providing a more efficient method for possible deep learning applications in synthetic CT generation.