Iris Bachmann

Ms. Iris Bachmann

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2024 in Analytical Chemistry
Verified
Journal Article
Closed access
IBIris Bachmann
Iris Bachmann
OBOle Behrmann
Ole Behrmann
MKMarcel Klingenberg-Ernst
Marcel Klingenberg-Ernst
MRMaja Rupnik
Maja Rupnik
FHFrank T. Hufert
Frank T. Hufert
Manfred WeidmannManfred Weidmann
Manfred Weidmann

17 June 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
OBOle Behrmann
Ole Behrmann
MHMatthias Hügle
Matthias Hügle
FEFranz Eckardt
Franz Eckardt
IBIris Bachmann
Iris Bachmann
CHCecilia Heller
Cecilia Heller
GDGregory Dame
Gregory Dame
We investigate the compatibility of three 3D printing materials towards real-time recombinase polymerase amplification (rtRPA). Both the general ability of the rtRPA reaction to occur while in contact with the cured 3D printing materials as well as the residual autofluorescence and fluorescence drift in dependence on post curing of the materials is characterized. We 3D printed monolithic rtRPA microreactors and subjected the devices to different post curing protocols. Residual autofluorescence and drift, as well as rtRPA kinetics, were then measured in a custom-made mobile temperature-controlled fluorescence reader (mTFR). Furthermore, we investigated the effects of storage on the devices over a 30-day period. Finally, we present the single- and duplex rtRPA detection of both the organism-specific Klebsiella haemolysin (khe) gene and the New Delhi metallo-β-lactamase 1 (blaNDM-1) gene from Klebsiella pneumoniae. Results: No combination of 3D printing resin and post curing protocol completely inhibited the rtRPA reaction. The autofluorescence and fluorescence drift measured were found to be highly dependent on printing material and wavelength. Storage had the effect of decreasing the autofluorescence of the investigated materials. Both khe and blaNDM-1 were successfully detected by single- and duplex-rtRPA inside monolithic rtRPA microreactors printed from NextDent Ortho Clear (NXOC). The reaction kinetics were found to be close to those observed for rtRPA performed in a microcentrifuge tube without the need for mixing during amplification. Singleplex assays for both khe and blaNDM-1 achieved a limit of detection of 2.5 × 101 DNA copies while the duplex assay achieved 2.5 × 101 DNA copies for khe and 2.5 × 102 DNA copies for blaNDM-1. Impact: We expand on the state of the art by demonstrating a technology that can manufacture monolithic microfluidic devices that are readily suitable for rtRPA. The devices exhibit very low autofluorescence and fluorescence drift and are compatible with RPA chemistry without the need for any surface pre-treatment such as blocking with, e.g., BSA or PEG.

25 June 2024 in Microorganisms
Verified
Journal Article
Open access
PDF file
CHCecilia Heller
Cecilia Heller
IBIris Bachmann
Iris Bachmann
MSMartin Spiegel
Martin Spiegel
FHFrank Torsten Hufert
Frank Torsten Hufert
GDGregory Dame
Gregory Dame
Rapid and accurate detection of Klebsiella pneumoniae carbapenem resistance is important for infection control and targeted antibiotic therapy. PCR-based assay performance heavily depends on the quality and quantity of template DNA. Challenges arise from the necessity to isolate chromosomal and large plasmid-encoded resistance genes simultaneously from a limited number of target cells and to remove PCR inhibitors. qPCRs for the detection of K. pneumoniae strains carrying blaOXA-48, blaNDM-1, blaKPC-2, and blaVIM-1 carbapenemase genes were developed. We compared the performance of template DNA extracted with silica column-based methods, reversed elution systems, and lysis-only methods either from diluted culture fluid or from a synthetic stool matrix which contained PCR inhibitors typically present in stool. The synthetic stool matrix was chosen to mimic K. pneumoniae containing rectal swabs or stool samples in a reproducible manner. For total DNA isolated from culture fluid, resistance gene detection by qPCR was always possible, independent of the extraction method. However, when total DNA was isolated from synthetic stool matrix spiked with K. pneumoniae, most methods were insufficient. The best performance of template DNA was obtained with reversed elution. This highlights the importance of choosing the right DNA extraction method for consistent carbapenem resistance detection by PCR.

2 August 2025 in Influenza and Other Respiratory Viruses
Verified
Journal Article
Open access
BBBenedikt Beilstein
Benedikt Beilstein
IBIris Bachmann
Iris Bachmann
MSMartin Spiegel
Martin Spiegel
FHFrank T. Hufert
Frank T. Hufert
GDGregory Dame
Gregory Dame
Background: Nucleic acid amplification tests (NAATs) for human adenoviruses (HAdVs) causing respiratory infections usually target the hexon gene. However, new HAdV types with substantial variations in the hexon gene may not be detected. Thus, we focus on NAATs based on a conserved region in the penton gene to detect all HAdV types causing respiratory infections.Methods: A highly conserved region at the 3′ end of the penton gene was chosen as a target for NAAT. Primers and probes for quantitative polymerase chain reaction (qPCR) and isothermal recombinase polymerase amplification (RPA) were designed for the detection of all HAdV types causing respiratory infections.Results: Two highly sensitive qPCR assays were established, one for the detection of HAdV‐E4 and HAdV‐B types and another for the detection of HAdV‐C types (LOD < 10 standard DNA copies for both assays). Furthermore, a one‐tube RPA with a universal RPA probe was developed for rapid detection of all HAdV types causing respiratory infections (LOD ≤ 244 standard DNA copies). All three assays were used for testing clinical nasopharyngeal swabs obtained from SARS‐CoV‐2‐negative children with respiratory disease symptoms. Eight out of 243 samples tested were found to be HAdV positive by qPCR and by one‐tube RPA, except for one sample with a very low viral load of 30 genome equivalents.Conclusions: Penton gene‐based NAAT systems were developed and successfully used for the detection of HAdV in clinical samples. The newly developed one‐tube RPA assay offers the possibility for rapid and simple detection of respiratory HAdV infections at the point of need.