Rengeng Zheng

Mr. Rengeng Zheng

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2024 in Buildings
Verified
Journal Article
Open access
PDF file
PSPei Song
Pei Song
XPXiaoxuan Peng
Xiaoxuan Peng
RZRengeng Zheng
Rengeng Zheng
Jun XiaJun Xia
Jun Xia
Autoclaved aerated concrete (AAC) has gained widespread acceptance in construction as a lightweight solution for exterior and interior walls. However, traditional steel-reinforced autoclaved aerated concrete (SR-AAC) has limitations, including concerns over its ductility and difficulty in cutting during installation. The steel reinforcement also has high embodied carbon that does not align with the actions in the construction section to reach carbon neutrality shortly. This study investigated the material properties and mechanical performances of factory-produced fiber-reinforced autoclaved aerated concrete (FR-AAC) panels, aiming to examine their potential as an alternative solution. Full-scale FR-AAC panels with thicknesses of 100 mm, 150 mm, and 200 mm were manufactured and tested. Some panels were down-sampled to determine the dry density, water absorption, compressive strength, and flexural strength of the material, while the mechanical performances were evaluated through static and impact loading tests. The results showed that the average dry density and absorption of the FR-AAC material are 533 kg/m3 and 63%, respectively, with compressive strengths up to 3.79 MPa and flexural strengths reaching 0.97 MPa. All six panels tested under static uniformly distributed loading exceeded the self-weight limit by a factor of 1.5, satisfying standard requirements for load-bearing capacity. However, the brittle failure modes observed in some tests raise potential health and safety concerns. In contrast, the impact tests revealed that the panels have acceptable performances with the inclusion of fibers.

10 December 2025 in International Journal of Architectural Engineering Technology
Verified
Journal Article
Open access
PDF file
Jun XiaJun Xia
Jun Xia
RZRengeng Zheng
Rengeng Zheng
XCXiaodong Cheng
Xiaodong Cheng
LTLihua Tan
Lihua Tan
The paper presents the process and results of the structural health monitoring of two long-span curved reinforced concrete frames using the distributed fibre optical sensor. Optical fibres were attached to the steel reinforcing bars to obtain temperature, strain, deformation, and cracking information for the beams and columns. The temperature measurements were used to adjust the strain readings, then obtain the stress, deformation, and crack width estimations. Five measurements along the history of construction were taken with the first data set as the baseline right after casting the beams. The remaining four are measurements at 14, 28, 89, and 288 days. The measurements revealed that both ends of the long-span beams only have limited lateral movement due to the high lateral stiffness of the columns. The maximum deflections of the two beams are estimated to be 29 mm and 45 mm, respectively, which satisfy the design requirements. The maximum crack widths of both beams are estimated to be much less than 0.3 mm. The presented work demonstrates the effectiveness of distributed fibre optical sensors in monitoring long-span reinforced concrete frames with limitations to be improved in the future implementations.

5 November 2026 in Journal of Building Engineering
Verified
Journal Article
Closed access
RZRengeng Zheng
Rengeng Zheng
QZQuan Zhou
Quan Zhou
Jun XiaJun Xia
Jun Xia
LSLuigi Di Sarno
Luigi Di Sarno
ELEngui Liu
Engui Liu