Zhi Liu

Dr. Zhi Liu

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ZLZhi Liu
Zhi Liu
CZChen Zhang
Chen Zhang
HYHeng Yuan
Heng Yuan
KYKaifeng Yin
Kaifeng Yin
YYYang Yang
Yang Yang
BHBangcheng Han
Bangcheng Han
We propose non-magnetic heating film based on indium tin oxide (ITO) and apply it in a miniaturized spin exchange relaxation free (SERF) gradient magnetometer. To achieve ultrahigh sensitivity, alkali metal atoms inside the vapor cell of the magnetometer require an elevated temperature field that is stable and uniform. ITO is a transparent and electrically conductive material which is suitable for such application and can be used as resistance wire to form the heating film. A film structure composed of an insulation layer sandwiched between two ITO layers with the same optimized pattern is used to configure the heating current to double back on itself to reduce the magnetic noise caused by it. Experiments show the proposed film can be heated to over 200 °C, which is sufficient for vaporizing alkali metal atoms such as potassium, rubidium, and cesium. The magnetic current coefficients of the heating films are below 0.2 nT/mA and with the high frequency heating current, low-frequency magnetic noise can be further reduced. We compare ITO-based heating films and conventional flexible printed circuit (FPC) heating films side by side in the same gradient magnetometer and with ITO films a more uniform temperature field and better intrinsic magnetic field sensitivity of 22 fT/cm/Hz $^{1/2}$ is achieved. The proposed ITO-based non-magnetic heating film can be used not only in atomic magnetometers but also in other atomic devices such as chip scale gyroscopes and atomic clocks.

29 April 2022 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
ZLZhi Liu
Zhi Liu
SZSheng Zou
Sheng Zou
KYKaifeng Yin
Kaifeng Yin
ZBZhou Binquan
Zhou Binquan
XNXiaolin Ning
Xiaolin Ning
HYHeng Yuan
Heng Yuan
A lifetime estimation model is proposed by characterizing the consumption of the components inside the atomic vapor cells in this work. The buffer gas leakage and alkali metal consumption in vapor cells will significantly destroy the performance of atomic magnetometers. Combining the light absorption method and aging experiments, the deterioration of helium pressure, rubidium vapor density, and cell wall transmittance were obtained to construct the lifetime estimation model that depends on time, working temperature, and initial contents. Then, the causes and consequences of these deteriorations were analyzed, and the combination of theoretical analysis and experimental data showed that the vapor cell invalidation caused by these factors conforms to the Weibull distribution. In order to establish the relationship between the component consumption and the performance of the magnetometer constituted by this cell, a single-beam magnetometer prototype was designed for sensitivity testing. Experiments have shown that the sensitivity of magnetometer is rapidly deteriorating after operating 600 h under 150 °C, which is mainly related to alkali metal consumption. Additionally, 200 °C is a trade-off aging experimental temperature between the aging efficiency and the stability of the cell. The proposed model can be applied to optimize the lifetime of the vapor cells used not only in magnetometers but also in gyroscopes and atomic clocks.

1 June 2017 in Physica B: Condensed Matter
Verified
Journal Article
Closed access
LQLiang Qiu
Liang Qiu
DQDongxiao Quan
Dongxiao Quan
FPFei Pan
Fei Pan
ZLZhi Liu
Zhi Liu

16 May 2024 in Photonics
Verified
Journal Article
Open access
PDF file
HZHongyang Zhu
Hongyang Zhu
BZBingquan Zhao
Bingquan Zhao
ZLZhi Liu
Zhi Liu
ZHZhen He
Zhen He
LDLihong Dong
Lihong Dong
XZXiaoming Zhao
Xiaoming Zhao
The cavity form of complex microcavity lasers predominantly relies on disordered structures, whether found in nature or artificially prepared. These structures, characterized by disorder, facilitate random lasing through the feedback effect of the cavity boundary and the internal scattering medium via various mechanisms. In this paper, we report on a random fiber laser employing a disordered scattering cladding medium affixed to the inner cladding of a hollow-core fiber. The internal flowing liquid gain establishes a stable liquid-core waveguide environment, enabling long-term directional coupling output for random laser emission. Through theoretical analysis and experimental validation, we demonstrate that controlling the disorder at the cavity boundary allows liquid-core fiber random microcavities to exhibit random lasing output with different mechanisms. This provides a broad platform for in-depth research into the generation and control of complex microcavity lasers, as well as the detection of scattered matter within micro- and nanostructures.

1 April 2023 in Chinese Physics B
Verified
Journal Article
Closed access
ZLZhi Liu
Zhi Liu
SZSheng Zou
Sheng Zou
KYKaifeng Yin
Kaifeng Yin
TSTao Shi
Tao Shi
JTJunjian Tang
Junjian Tang
HYHeng Yuan
Heng Yuan
A robust performance evaluation method for vapor cells used in magnetometers is proposed in this work. The performance of the vapor cell determines the sensitivity of the magnetic measurement, which is the core parameter of a magnetometer. After establishing the relationship between intrinsic sensitivity and the total relaxation rate, the total relaxation rate of the vapor cell can be obtained to represent the intrinsic sensitivity of the magnetometer by fitting the parameters of the magnetic resonance experiments. The method for measurement of the total relaxation rate based on the magnetic resonance experiment proposed in this work is robust and insensitive to ambient noise. Experiments show that, compared with conventional sensitivity measurement, the total relaxation rate affected by magnetic noise below 0.9 nT, pump light frequency noise below 1.5 GHz, pump light power noise below 9%, probe light power noise below 3% and temperature fluctuation of 150 ± 3 °C deviates by less than 2% from the noise-free situation. This robust performance evaluation method for vapor cells is conducive to the construction of a multi-channel high-spatial-resolution cardio-encephalography system.

1 August 2024 in Advanced Quantum Technologies
Verified
Journal Article
Closed access
ZLZhi Liu
Zhi Liu
LDLihong Dong
Lihong Dong
ZQZhe Qi
Zhe Qi
HZHongyang Zhu
Hongyang Zhu
BZBingquan Zhao
Bingquan Zhao
XZXiaoming Zhao
Xiaoming Zhao