Jiazhen He

Dr. Jiazhen He


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2018 in Materials
Verified
Journal Article
Open access
PDF file
JHJiazhen He
Jiazhen He
YLYehu Lu
Yehu Lu
LWLijun Wang
Lijun Wang
NMNini Ma
Nini Ma
This study explored the application of shape memory alloy (SMA) springs in a multilayer protective fabric assembly for intelligent insulation that responded to thermal environment changes. Once the SMA spring was actuated, clothing layers were separated, creating an adjustable air gap between the adjacent fabric layers. The impacts of six different SMA arrangement modes and two different spring sizes on thermal protection against either a radiant heat exposure (12 kW/m2) or a hot surface exposure (400 °C) were investigated. The findings showed that the incorporation of SMA springs into the fabric assembly improved the thermal protection, but the extent to which the springs provided thermal protection was dependent on the arrangement mode and spring size. The effectiveness of reinforcing the protective performance using SMA springs depended on the ability of clothing layers to expand an air layer. The regression models were established to quantitatively assess the relationship between the air gap formed by SMA spring and the thermal protective performance of clothing. This study demonstrated the potential of SMA spring as a suitable material for the development of intelligent garments to provide additional thermal protection and thus reduce the number of clothing layers for transitional thermal protective clothing.

13 November 2018 in International Journal of Occupational Safety and Ergonomics
Verified
Journal Article
Closed access
LWLijun Wang
Lijun Wang
JHJiazhen He
Jiazhen He
YLYehu Lu
Yehu Lu
SJShumin Jiang
Shumin Jiang
MWMin Wang
Min Wang
In this study, common flame-retardant fabrics were treated with single washing or abrasion and their interactions to simulate wearing away during use. The changes in thickness, mass/m2 and protective performance of the fabrics under both flame and radiation environments were evaluated. Results demonstrated that the protective performance was firstly increased after washing or abrasion, and then decreased with further increasing washing or abrasion cycles. After certain treatment cycles, the combined effect of washing and abrasion was significantly greater than the single effect of washing or abrasion alone. The interaction modes of washing and abrasion also showed significant differences in protective performance under a flame test. Under radiation exposure, the effect of combined washing and abrasion was more obvious. There was a positive correlation between the fabric weight and its protective performance with different treatments. The findings provide useful guidance for the actual use and maintenance of protective clothing.

26 September 2022 in International Journal of Occupational Safety and Ergonomics
Verified
Journal Article
Closed access
XZXiaorong Zhu
Xiaorong Zhu
JHJiazhen He
Jiazhen He
KRKe Rui
Ke Rui
QZQianwen Zhou
Qianwen Zhou
MWMin Wang
Min Wang
Occupational workers in thermal exposure have frequent physical activities that may lead to fabric deformation of thermal protective clothing. To deeply understand the impact of fabric deformation on its dual thermal protective and thermal hazardous performance, a modified experimental instrument was used to simulate different extents of fabric tensile deformation and compression deformation. The results demonstrated that increasing tensile ratios during exposure decreased heat storage within a fabric system, but increased the skin absorbed energy. Tensile ratios had a more negative impact on the thermal protective performance of a single-layer fabric than of a double-layer fabric system. Increasing tensile ratios during cooling decreased heat discharge to the skin, but the applied compression significantly improved the heat discharge. In addition, regression models were established to examine the effect of fabric deformation and demonstrated that the thermal hazardous performance of fabrics was more affected by compression than by tensile deformation.

14 November 2024 in International Journal of Clothing Science and Technology
Verified
Journal Article
Closed access
QZQingqing Zhang
Qingqing Zhang
JHJiazhen He
Jiazhen He
LDLili Dai
Lili Dai
ZCZhongwei Chen
Zhongwei Chen
JGJinping Guan
Jinping Guan
AHAifang He
Aifang He
Purpose: On the basis of demand survey feedback from individuals with disabilities and caregivers, this study designed two sets of functional garments for long-term bedridden patients, with the primary objective of increasing convenience and reducing the physical workload of caregivers.Design/methodology/approach: Wear trials were conducted by employing 24 subjects to perform 11 different tasks to compare the performance of the two newly developed garments with that of conventional hospital patient apparel. Task operation time, heart rate (HR), electromyography (EMG) signals, and subjective perceptions were evaluated.Findings: The new functional garments reduced the time required to perform tasks by 29–79%, maintained the average HR of caregivers at approximately the resting threshold and resulted in a 37–74% reduction in the root mean square (RMS) of the EMG at the arm muscles in the private and thigh nursing tasks. All the subjective and objective evaluation results of the caregivers demonstrated varying degrees of correlation.Practical implications: This study has practical implications for the design of functional clothing for long-term bedridden patients and provides guidance for evaluating the ergonomics of garments that can be utilized only with caregiver support.Originality/value: In contrast to previous studies that focused primarily on individuals with disabilities while overlooking the indispensable role of caregivers in the nursing process, this study shifted its emphasis to long-term bedridden patients who relied exclusively on caregivers for daily activities. Additionally, this study attempted to analyze the correlations between the evaluation parameters to explore the relationships between the evaluation methods.