Yayu Yang

Prof. Dr. Yayu Yang

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
YYYayu Yang
Yayu Yang
NTNingling Tai
Ningling Tai
CFChunju Fan
Chunju Fan
LYLian Yang
Lian Yang
SCShi Chen
Shi Chen
Direct‐current (DC) line faults are a major issue in ultra‐high‐voltage direct‐current systems due to the complex and wicked environment. Thus, reliably detecting and isolating the DC line faults are not a trivial engineering task. This study proposes a DC line protection scheme based on resonance frequency. The scheme mainly consists of a fault discrimination criterion and a faulty pole selection criterion. The fault discrimination criterion is based on the phase of the resonance frequency impedance, and it is deployed to differentiate the faults on the protected DC line from the external faults. The faulty pole selection criterion is based on the ratio of the resonance frequency currents, and it is employed to select the faulty pole. The sensitivity analysis demonstrates that the performance of the proposed protection is promising. The simulations carried out in PSCAD/EMTDC under various conditions verify the feasibility and validity of the proposed protection scheme.

28 June 2022 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
SYShu Ye
Shu Ye
FZFeng Zhang
Feng Zhang
Fei GaoFei Gao
Fei Gao
ZZZhongzheng Zhou
Zhongzheng Zhou
YYYayu Yang
Yayu Yang
Multilevel converters play an important role in power electronic systems. In recent years, data-driven fault diagnosis technologies for multilevel converters have rapidly developed and are generally based on feature engineering and intelligent classification algorithms. However, the fault detection rate, speed and stability still need to be improved, especially for complex converter systems. In this paper, based on a probabilistic autoencoder architecture, an affine-invariant Riemannian metric autoencoder (AIRMAE) is proposed for feature extraction, and combined with classifiers, a supervised learning fault diagnosis method for multilevel converters is constructed. The proposed AIRMAE is able to investigate low-dimensional representations from high-dimensional data manifolds while preserving sufficient valid information. Based on a five-level nested neutral-point piloted (NNPP) converter, the effectiveness of the proposed method is verified by experiments. The performance is superior to that of existing state-of-the-art fault diagnosis methods, with high detection accuracy, good stability and strong waveform reconstruction ability.

12 August 2023 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
BTBaichuan Teng
Baichuan Teng
JMJianjun Ma
Jianjun Ma
MZMiao ZHU
Miao ZHU
YYYayu Yang
Yayu Yang
XCXu Cai
Xu Cai
DC short‐circuit fault has become one of the major concerns in bipolar DC system operation under complicated conditions. Compared with conventional two‐port DC‐DC converter, fault‐tolerant DC‐DC converter with multiple external ports is evaluated as a preferential choice for high reliability, availability and flexibility required bipolar DC system due to its capability of fault reconfiguration. This article focuses on a type of fault‐tolerant DC‐DC converter interconnected with DC bus and integrated energy storage devices applied in bipolar DC system and theoretical analyses on transmitted power characteristics under bipolar mode and monopolar mode are also carried out in this article. For bipolar mode, the minimized‐peak‐current control strategy is proposed to reduce current stress on switching devices. As for monopolar mode and source‐port fault mode, the fault reconfiguration method and constant‐transmitted‐power control strategy are designed to eliminate fault impaction and achieve the constant transmitted power of output port connected with critical load, by means of power sharing between input port and normal output port or between the normal output ports. Furthermore, intersection of zero‐voltage‐switching (ZVS) operation area under different working modes is depicted with consideration of two optimizing control. Finally, the performance of the proposed fault reconfiguration method and optimizing control have been tested in PLECS environment and experimental prototype to verify the reliability and flexibility.

19 August 2022 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
YYYayu Yang
Yayu Yang
NTNingling Tai
Ningling Tai
YLYu Liu
Yu Liu
XZXiaodong Zheng
Xiaodong Zheng
JMJianjun Ma
Jianjun Ma
SYShu Ye
Shu Ye
The current differential protection for high‐voltage direct current (HVDC) transmission lines has low reliability due to the distributed capacitive current and time delay. This paper proposes a pilot directional protection, which is based on the calculated DC resistance (CDCR) at both ends of DC lines. The characteristics of superimposed components and CDCR are analysed using the superposition theorem. The magnitude of CDCR is equal to the resistance of the converter for a forward internal fault, while it is equal to the sum of the line's DC resistance and the converter's resistance for a reverse fault. CDCR is a useful characteristic to construct the protection scheme as the resistance of DC line is significantly greater than that of the converter. Detailed simulation tests carried out on PSCAD/EMTDC under different fault conditions show that the proposed scheme is able to identify internal and external faults accurately.

26 August 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
YYYayu Yang
Yayu Yang
BJBinjie Jin
Binjie Jin
JMJianjun Ma
Jianjun Ma
WZWeixiang Zhou
Weixiang Zhou
KWKangan Wang
Kangan Wang
Medium-voltage dc (MVdc) shipboard power systems (SPSs) offer advantages in operational flexibility and reliability over ac systems. However, the high-performance MVdc SPS in IEEE Std 1709TM-2018 is hindered by architectural complexity and poor economic performance due to the extensive use of dc circuit breakers (DCCBs). To overcome these challenges, an improved notional MVdc SPS is proposed in this study. The design replaces two-port DCCBs with multiport DCCBs (MP-DCCBs), employs current-limiting reactors (CLRs) to limit fault current, and simplifies the system by reducing the number of nodes from 18 to 7. A detailed PSCAD/EMTDC simulation model demonstrates robust and effective dynamic performance under various operating conditions, including generator outages and propulsion motor speed changes. Sensitivity analysis not only confirms the system’s reliability and survivability but also specifically validates the effectiveness of CLRs in suppressing the fault current rise rate. A comparative analysis shows that the proposed architecture offers a balanced and competitive advantage across complexity, flexibility, survivability, and cost-effectiveness.

Verified
Journal Article
Open access
PDF file
HLHuanbo Liu
Huanbo Liu
YGYi Guo
Yi Guo
YYYayu Yang
Yayu Yang
BHBing Han
Bing Han
As a pivotal element in the maritime sector’s green transition, fuel-cell-powered ships have attracted increasing attention due to the energy efficiency and stability of their onboard powertrains. Yet, the dynamic coordination and capacity optimization of fuel cells and supercapacitors remain among the most formidable technological challenges. In this study, a hybrid marine power system pairing fuel cells with supercapacitors is devised by integrating robust control with a particle swarm optimization (PSO) algorithm. The results reveal that, under complex operating conditions, robust control effectively mitigates system uncertainties and secures reliable operation of the ship’s energy system. Optimally allocating component capacities via PSO markedly enhances the synergy between the fuel cell and the supercapacitor. Compared with conventional schemes, optimized architecture boosts energy efficiency by 12.5%, shortens response time by 8.4%, and demonstrates clear superiority in robustness and stability. This robust-control-based hybrid configuration therefore delivers outstanding performance and offers compelling guidance for the refined design of marine propulsion systems.