John Seymour

Dr. John Seymour


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2007 in Biomaterials
Verified
Journal Article
Closed access
JSJohn Seymour
John Seymour
DKDaryl R. Kipke
Daryl R. Kipke

19 July 2017 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
SWSteven M. Wellman
Steven M. Wellman
JEJames R. Eles
James R. Eles
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
JSJohn Seymour
John Seymour
NMNicholas J. Michelson
Nicholas J. Michelson
TKTakashi Kozai
Takashi Kozai

2 January 2017 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
JSJohn Seymour
John Seymour
FWFan Wu
Fan Wu
KWKensall D. Wise
Kensall D. Wise
EYEuisik Yoon
Euisik Yoon
Mapping brain activity has received growing worldwide interest because it is expected to improve disease treatment and allow for the development of important neuromorphic computational methods. MEMS and microsystems are expected to continue to offer new and exciting solutions to meet the need for high-density, high-fidelity neural interfaces. Herein, the state-of-the-art in recording and stimulation tools for brain research is reviewed, and some of the most significant technology trends shaping the field of neurotechnology are discussed.

15 June 2015 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
TKTakashi Kozai
Takashi Kozai
KCKasey Catt
Kasey Catt
ZDZhanhong Du
Zhanhong Du
KNKyounghwan Na
Kyounghwan Na
OSOnnop Srivannavit
Onnop Srivannavit
XCXinyan Cui
Xinyan Cui
Objective: Subcellular-sized chronically implanted recording electrodes have demonstrated significant improvement in single unit (SU) yield over larger recording probes. Additional work expands on this initial success by combining the subcellular fiber-like lattice structures with the design space versatility of silicon microfabrication to further improve the signal-to-noise ratio, density of electrodes, and stability of recorded units over months to years. However, ultrasmall microelectrodes present very high impedance, which must be lowered for SU recordings. While poly(3,4-ethylenedioxythiophene) (PEDOT) doped with polystyrene sulfonate (PSS) coating have demonstrated great success in acute to early-chronic studies for lowering the electrode impedance, concern exists over long-term stability. Here, we demonstrate a new blend of PEDOT doped with carboxyl functionalized multiwalled carbon nanotubes (CNTs), which shows dramatic improvement over the traditional PEDOT/PSS formula. Methods: Lattice style subcellular electrode arrays were fabricated using previously established method. PEDOT was polymerized with carboxylic acid functionalized carbon nanotubes onto high-impedance (8.0 ± 0.1 MΩ: M ± S.E.) 250-μm 2 gold recording sites. Results: PEDOT/CNT-coated subcellular electrodes demonstrated significant improvement in chronic spike recording stability over four months compared to PEDOT/PSS recording sites. Conclusion: These results demonstrate great promise for subcellular-sized recording and stimulation electrodes and long-term stability. Significance: This project uses leading-edge biomaterials to develop chronic neural probes that are small (subcellular) with excellent electrical properties for stable long-term recordings. High-density ultrasmall electrodes combined with advanced electrode surface modification are likely to make significant contributions to the development of long-term (permanent), high quality, and selective neural interfaces.

1 October 2009 in Biomaterials
Verified
Journal Article
Closed access
JSJohn Seymour
John Seymour
YEYaseen M. Elkasabi
Yaseen M. Elkasabi
HCHsien-Yeh Chen
Hsien-Yeh Chen
JLJoerg Lahann
Joerg Lahann
DKDaryl R. Kipke
Daryl R. Kipke

28 April 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
KKKanghwan Kim
Kanghwan Kim
MVMihály Vöröslakos
Mihály Vöröslakos
JSJohn Seymour
John Seymour
KWKensall D. Wise
Kensall D. Wise
GBGyörgy Buzsáki
György Buzsáki
EYEuisik Yoon
Euisik Yoon
The combination of in vivo extracellular recording and genetic-engineering-assisted optical stimulation is a powerful tool for the study of neuronal circuits. Precise analysis of complex neural circuits requires high-density integration of multiple cellular-size light sources and recording electrodes. However, high-density integration inevitably introduces stimulation artifact. We present minimal-stimulation-artifact (miniSTAR) μLED optoelectrodes that enable effective elimination of stimulation artifact. A multi-metal-layer structure with a shielding layer effectively suppresses capacitive coupling of stimulation signals. A heavily boron-doped silicon substrate silences the photovoltaic effect induced from LED illumination. With transient stimulation pulse shaping, we reduced stimulation artifact on miniSTAR μLED optoelectrodes to below 50 μVpp, much smaller than a typical spike detection threshold, at optical stimulation of >50 mW mm–2irradiance. We demonstrated high-temporal resolution (<1 ms) opto-electrophysiology without any artifact-induced signal quality degradation during in vivo experiments. MiniSTAR μLED optoelectrodes will facilitate functional mapping of local circuits and discoveries in the brain.