Ondřej Michal

Dr. Ondřej Michal

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2024 in Measurement
Verified
Journal Article
Open access
MŠMartin Štroner
Martin Štroner
RURudolf Urban
Rudolf Urban
TKTomáš Křemen
Tomáš Křemen
JBJaroslav Braun
Jaroslav Braun
OMOndřej Michal
Ondřej Michal
TJTomáš Jiřikovský
Tomáš Jiřikovský

19 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ACAnna Chrbolková
Anna Chrbolková
MŠMartin Štroner
Martin Štroner
RURudolf Urban
Rudolf Urban
OMOndřej Michal
Ondřej Michal
TKTomáš Křemen
Tomáš Křemen
JBJaroslav Braun
Jaroslav Braun
This study presents a comprehensive comparison of static and SLAM (Simultaneous Localization and Mapping) laser scanners of both new and old generation in a controlled indoor environment of a standard commercial building with long, linear corridors and recesses. The aim was to assess both global and local accuracy, as well as noise characteristics, of each scanner. Methods: A highly accurate static scanner was used to generate a reference point cloud. Five devices were evaluated: two static scanners (Leica RTC 360 and Trimble X7) and three SLAM scanners (GeoSLAM ZEB Horizon RT, Emesent Hovermap ST-X, and FARO Orbis). Accuracy analysis included systematic and random error assessment, axis-specific displacement evaluation, and profile-based local accuracy measurements. Additionally, noise was quantified before and after data smoothing. Static scanners yielded superior accuracies, with the Leica RTC 360 achieving the best performance (absolute accuracy of 1.2 mm). Among SLAM systems, the Emesent Hovermap ST-X and FARO Orbis—both newer-generation devices—demonstrated significant improvements over the older-generation GeoSLAM ZEB Horizon RT. After smoothing, the noise levels of these new-generation SLAM scanners (approx. 2.1–2.2 mm) approached those of static systems. The findings underline the ongoing technological progress in SLAM systems, with the new-generation SLAM scanners becoming increasingly viable alternatives to static scanners, especially when speed, ease of use, and reduced occlusions are prioritized. This makes them well-suited for rapid indoor mapping applications, provided that the slightly lower accuracy is acceptable for the intended use.

5 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
OMOndřej Michal
Ondřej Michal
MŠMartin Štroner
Martin Štroner
The optimization of measurements in a geodetic network (second-order design) has been investigated in the past; however, the practical usability of the outcomes of most of such studies is doubtful. Hence, we have proposed a new automated optimization algorithm, taking into account the practical aspects of total station measurements. The algorithm consists of four parallel partial algorithms, of which one is subsequently automatically selected—the one meeting the geodetic network accuracy requirements with the lowest number of necessary measurements. We tested the algorithm (and individual partial algorithms) on four geodetic networks designed to resemble real-world networks with 50–500 modifications to each of those networks in individual tests. The results indicate that (i) the results achieved by the combined algorithm are close to the optimal results and (ii) none of the four partial algorithms universally performs the best, implying that the combination of the four partial algorithms is necessary for achieving the best possible results of geodetic network optimization.

27 June 2015 in Geoinformatics FCE CTU
Verified
Journal Article
Open access
PDF file
OMOndřej Michal
Ondřej Michal
RURudolf Urban
Rudolf Urban
In current time the large amount of pre-stressed bridge structures is used. Their horizontal and vertical displacements are well predicted, but for verification of theoretical results is necessary to measure real displacements of these structures depending on external conditions. Given by the complexity of the design and by the inhomogeneity of external influences (especially temperature of the atmosphere, insolation, wind speed, etc.) cannot yet be reliably determined the changes of the construction caused by the immediate state of the environment and to distinguish them from irreversible (permanent) deformation of the structure.In this paper the deflection line of the bridge of general Chábera over river Labe during the all-day monitoring will be analyzed. There is dense coverage of stabilized points enabling accurate approximation of the displacement of the bridge structure. The paper is focused especially on temperature effects on the bridge structure. The temperature changes cause the deformation of the construction not immediately, but with the time shift between change of temperature and structure deformation. Although the points are stabilized on both sides of the bridge deck, for the analysis of results were used only the points on the left side of the main span, where the biggest vertical displacements was detected. For testing of dependence of the time shift between the structure deformations and the structure temperature the Pearson coefficient of correlation was used.