Owing to the consistent increase in energy efficiency issues, studies for improving the charging efficiency and energy density of batteries have been receiving attention in the electric vehicle transportation sector. This paper deals with an online electric vehicle (OLEV) system which utilizes the dc power system for reducing loss as well as reducing the size of the required battery capacity. Intensive research on grid integration with OLEV has not been performed until recently and it is necessary to calculate the power flow analysis considering the unique characteristics of OLEV for the commercialization of this new transport system (for the application of this new system in the transport sector). In this paper, the dc OLEV power system is being investigated for reducing line losses and peak power thereby reducing the electric cost levied on the substation. Verification processes are performed through simulation for various scenarios to examine the effectiveness of the proposed system in terms of power consumption, battery state of charge, peak power, and loss reduction.
25 October 2016 in IEEE Transactions on Power Systems
Owing to the large physical area of a wind farm, some uncertainty and inefficiency issues exist in the related power delivery process. To provide required ancillary services regarding reactive power for the utility grid, further optimization processes are needed to maintain the reliability and efficiency of the entire system. In this paper, we introduce a reactive power assignment strategy that is based on the linearized system components of a wind farm, which comprises a power conversion system. Additionally, we perform realistic assignment processes to verify the effectiveness of this strategy with electromagnetic transients using dc software tool. Reducing the total apparent power flow by utilizing the radial structure of the wind farm is explored by assigning reactive power to nearby wind turbines. The verification process focuses on comparing the loss in output profile of a normal assignment and the proposed method in a designated wind farm.
Recent development and cost down of PV(Photovoltaic) technology drive change of power system structure. The participation of PV generation is increasing, and the size of each PV farm is getting larger. In order to integrate large PV farms into the main grid, substation for interconnection needs to be sized properly. Unlike substations for load and conventional generators, PV farm substation has an uneven utilization ratio due to characteristics of solar radiation. With proper sizing method for the capacity of the substation can reduce the building cost of facilities. A combination of an energy storage system can further reduce the capacity of the substation. Battery energy storage system (BESS) can shift the peak production of PV during the daytime to midnight. According to market circumstances, BESS can reduce further construction costs by producing profit based on time difference of electric cost. For proper sizing of substation capacity, several factors must be considered including environmental factors, market structure and BESS in the system. In this paper, a series of assessment methodology is introduced to calculate the optimized capacity of substation and BESS for PV farm interconnection. The long-term solar radiation data is analyzed for a given site of the PV farm. Based on market structure, the operation of BESS is optimized to make maximum profit during operation. The iterative calculation of each step results in the calculation of the optimized capacity of BESS and substation for given PV farm size.
Microgrids, denoting small-scale and self-sustaining grids, constitute a pivotal component in future power systems with a high penetration of renewable generators. The inherent uncertainty tied to renewable power generation, typified by photovoltaic and wind turbine systems, necessitates counterbalancing mechanisms. These mechanisms encompass Energy storage systems or conventional thermal fossil-fuel generators imbued with heightened flexibility. Addressing the uncertainty stemming from renewable generators mandates a cost-effective assessment and operational strategy for said compensatory devices. To this end, myriad uncertainty factors warrant scrutiny, conceivably concretized into a unified probability distribution function (PDF) that takes into account their temporal inter-dependencies. Diverse uncertainty factors, characterized by varying marginal distributions and scales, can be assimilated into a multivariate probability distribution through a conversion to normal distributions via rank correlation. However, with the escalation in the number of uncertainty factors embraced within a microgrid context, the endeavour becomes notably intricate when aiming to define conditional probability distributions originating from joint PDFs. This paper presents a method proposing the modelling of net-load forecast error distribution, considering the interplay among uncertainty factors. The approach introduces a data-driven Gaussian process regression technique for training and validating conditional PDFs among these uncertainty factors. Notably, this approach facilitates the transformation of said factors into normal distributions while preserving their inherent marginal characteristics. The resultant conditional density function, as per the proposed methodology, exhibits enhanced suitability for estimating net-load error distribution. Consequently, the conditional density function stemming from this proposed approach demonstrates superior aptitude in approximating the distribution of net load error.
As the penetration rate of renewable enery resources (RES) in the power system increases, uncertainty and variability in system operation increase. The application of energy storage systems (ESS) in the power system has been increased to compensate for the characteristics of renewable energy resources. Since ESS is a controllable and highly responsive power resource, primary frequency response and inertia response are possible in case of system contingency, so it can be utilized for frequency regulation (FR) purposes. In frequency regulation, reduction of the Rate of Change of Frequency (RoCoF) and increase the frequency nadir by improving the response characteristics are important factors to secure frequency stability. Therefore, it is important to control ESS with proper parameters according to changing system situation. In this paper, we propose a method to calculate and apply a frequency droop, which is basically required according to the power system condition based on swing equation and effective inertia assessment. In addition, a method to estimate RoCoF droop according to the correlation with frequency by estimating the systematic inertia in the current situation is proposed. The case study for verification of the proposed method was performed through dynamic simulation using actual Korean power system data. The results show that the proposed method is more effective than the governor-free of the conventional thermal generator and conventional droop control-based FR-ESS.