Sandra I Woolley

Dr. Sandra I Woolley

Computer Science and Mathematics, Keele University, Newcastle-under-Lyme, UK
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2021 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
DRDaniel Ray
Daniel Ray
Tim CollinsTim Collins
Tim Collins
Sandra I WoolleySandra I Woolley
Sandra I Woolley
PPPrasad Ponnapalli
Prasad Ponnapalli
Optical pulse detection photoplethysmography (PPG) provides a means of low cost and unobtrusive physiological monitoring that is popular in many wearable devices. However, the accuracy, robustness and generalizability of single-wavelength PPG sensing are sensitive to biological characteristics as well as sensor configuration and placement; this is significant given the increasing adoption of single-wavelength wrist-worn PPG devices in clinical studies and healthcare. Since different wavelengths interact with the skin to varying degrees, researchers have explored the use of multi-wavelength PPG to improve sensing accuracy, robustness and generalizability. This paper contributes a novel and comprehensive state-of-the-art review of wearable multi-wavelength PPG sensing, encompassing motion artifact reduction and estimation of physiological parameters. The paper also encompasses theoretical details about multi-wavelength PPG sensing and the effects of biological characteristics. The review findings highlight the promising developments in motion artifact reduction using multi-wavelength approaches, the effects of skin temperature on PPG sensing, the need for improved diversity in PPG sensing studies and the lack of studies that investigate the combined effects of factors. Recommendations are made for the standardization and completeness of reporting in terms of study design, sensing technology and participant characteristics.

10 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Tim CollinsTim Collins
Tim Collins
Sandra I WoolleySandra I Woolley
Sandra I Woolley
SOSalome Oniani
Salome Oniani
Ivan Miguel PiresIvan Miguel Pires
Ivan Miguel Pires
Nuno M. GarciaNuno M. Garcia
Nuno M. Garcia
APAnand Pandyan
Anand Pandyan
This paper addresses the significant need for improvements in device version reporting and practice across the academic and technical activity monitoring literature, and it recommends assessments for new and updated consumer sensing devices. Reproducibility and data veracity are central to good scholarship, and particularly significant in clinical and health applications. Across the literature there is an absence of device version reporting and a failure to recognize that device validity is not maintained when firmware and software updates can, and do, change device performance and parameter estimation. In this paper, we propose the use of tractable methods to assess devices at their current version and provide an example empirical approach. Experimental results for heart rate and step count acquisitions during walking and everyday living activities from Garmin Vivosmart 3 (v4.10) wristband monitors are presented and analyzed, and the reliability issues of optically-acquired heart rates, especially during periods of activity, are demonstrated and discussed. In conclusion, the paper recommends the empirical assessment of new and updated activity monitors and improvements in device version reporting across the academic and technical literature.

10 June 2020 in Electronics
Verified
Journal Article
Open access
PDF file
TRTendai Rukasha
Tendai Rukasha
Sandra I WoolleySandra I Woolley
Sandra I Woolley
TKTheocharis Kyriacou
Theocharis Kyriacou
Tim CollinsTim Collins
Tim Collins
Epilepsy is a neurological disorder that affects 50 million people worldwide. It is characterised by seizures that can vary in presentation, from short absences to protracted convulsions. Wearable electronic devices that detect seizures have the potential to hail timely assistance for individuals, inform their treatment, and assist care and self-management. This systematic review encompasses the literature relevant to the evaluation of wearable electronics for epilepsy. Devices and performance metrics are identified, and the evaluations, both quantitative and qualitative, are presented. Twelve primary studies comprising quantitative evaluations from 510 patients and participants were collated according to preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines. Two studies (with 104 patients/participants) comprised both qualitative and quantitative evaluation components. Despite many works in the literature proposing and evaluating novel and incremental approaches to seizure detection, there is a lack of studies evaluating the devices available to consumers and researchers, and there is much scope for more complete evaluation data in quantitative studies. There is also scope for further qualitative evaluations amongst individuals, carers, and healthcare professionals regarding their use, experiences, and opinions of these devices.

1 January 1999 in IBM Systems Journal
Verified
Journal Article
Closed access
CBChris Baber
Chris Baber
DHD. J. Haniff
D. J. Haniff
Sandra I WoolleySandra I Woolley
Sandra I Woolley
In this paper, current applications of wearable computers are reviewed and categorized according to dimensions of "time" and "reference." The time dimension is based on whether the system uses information that is stored, information that is current, or information that can help in predicting future events. The reference dimension is concerned with the type of application, event, task, environment, person, or artifact. Each of these categories can be described in terms of its temporal features (stored, current, or predicted). It is proposed that these dimensions distinguish wearable computers from their desk-bound counterparts, and this raises the question of appropriate paradigms for wearable computers. A user- centered methodology is then presented and illustrated by paramedic and fire-fighter applications.

1 December 2019 in Electronics
Verified
Journal Article
Open access
PDF file
Tim CollinsTim Collins
Tim Collins
Sandra I WoolleySandra I Woolley
Sandra I Woolley
EGErlend Gehlken
Erlend Gehlken
ECEugene Ch'ng
Eugene Ch'ng
The photogrammetric acquisition of 3D object models can be achieved by Structure from Motion (SfM) computation of photographs taken from multiple viewpoints. All-around 3D models of small artefacts with complex geometry can be difficult to acquire photogrammetrically and the precision of the acquired models can be diminished by the generic application of automated photogrammetric workflows. In this paper, we present two versions of a complete rotary photogrammetric system and an automated workflow for all-around, precise, reliable and low-cost acquisitions of large numbers of small artefacts, together with consideration of the visual quality of the model textures. The acquisition systems comprise a turntable and (i) a computer and digital camera or (ii) a smartphone designed to be ultra-low cost (less than $150). Experimental results are presented which demonstrate an acquisition precision of less than 40 μ m using a 12.2 Megapixel digital camera and less than 80 μ m using an 8 Megapixel smartphone. The novel contribution of this work centres on the design of an automated solution that achieves high-precision, photographically textured 3D acquisitions at a fraction of the cost of currently available systems. This could significantly benefit the digitisation efforts of collectors, curators and archaeologists as well as the wider population.

1 May 2004 in International Journal of Human-Computer Studies
Verified
Journal Article
Closed access
HBHuw W Bristow
Huw W Bristow
CBChris Baber
Chris Baber
JCJames Cross
James Cross
JKJames F Knight
James F Knight
Sandra I WoolleySandra I Woolley
Sandra I Woolley