Bonex Mwakikunga

Prof. Bonex Mwakikunga


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Results in Physics
Verified
Journal Article
Open access
PKPierre M. Kibasomba
Pierre M. Kibasomba
SDSimon Dhlamini
Simon Dhlamini
MMMalik Maaza
Malik Maaza
CLChuan-Pu Liu
Chuan-Pu Liu
Mohamed M. RashadMohamed M. Rashad
Mohamed M. Rashad
BMBonex Mwakikunga
Bonex Mwakikunga

31 January 2018 in Diagnostics
Verified
Journal Article
Open access
PDF file
Valentine SaasaValentine Saasa
Valentine Saasa
TMThomas Malwela
Thomas Malwela
MBMervyn Beukes
Mervyn Beukes
MMMatlou Mokgotho
Matlou Mokgotho
CLChaun-Pu Liu
Chaun-Pu Liu
BMBonex Mwakikunga
Bonex Mwakikunga
The review describes the technologies used in the field of breath analysis to diagnose and monitor diabetes mellitus. Currently the diagnosis and monitoring of blood glucose and ketone bodies that are used in clinical studies involve the use of blood tests. This method entails pricking fingers for a drop of blood and placing a drop on a sensitive area of a strip which is pre-inserted into an electronic reading instrument. Furthermore, it is painful, invasive and expensive, and can be unsafe if proper handling is not undertaken. Human breath analysis offers a non-invasive and rapid method for detecting various volatile organic compounds thatare indicators for different diseases. In patients with diabetes mellitus, the body produces excess amounts of ketones such as acetoacetate, beta-hydroxybutyrate and acetone. Acetone is exhaled during respiration. The production of acetone is a result of the body metabolising fats instead of glucose to produce energy. There are various techniques that are used to analyse exhaled breath including Gas Chromatography Mass Spectrometry (GC–MS), Proton Transfer Reaction Mass Spectrometry (PTR–MS), Selected Ion Flow Tube-Mass Spectrometry (SIFT–MS), laser photoacoustic spectrometry and so on. All these techniques are not portable, therefore this review places emphasis on how nanotechnology, through semiconductor sensing nanomaterials, has the potential to help individuals living with diabetes mellitus monitor their disease with cheap and portable devices.

1 December 2016 in Applied Surface Science
Verified
Journal Article
Closed access
Gugu Hlengiwe MhlongoGugu Hlengiwe Mhlongo
Gugu Hlengiwe Mhlongo
KSKatekani Shingange
Katekani Shingange
ZTZamaswazi P. Tshabalala
Zamaswazi P. Tshabalala
BDBaban P. Dhonge
Baban P. Dhonge
FMFawzy A. Mahmoud
Fawzy A. Mahmoud
DMDavid E. Motaung
David E. Motaung

4 June 2014 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
DMDavid Motaung
David Motaung
Gugu Hlengiwe MhlongoGugu Hlengiwe Mhlongo
Gugu Hlengiwe Mhlongo
SNS. S. Nkosi
S. S. Nkosi
GMG. F. Malgas
G. F. Malgas
BMBonex Mwakikunga
Bonex Mwakikunga
Suprakas Sinha RaySuprakas Sinha Ray
Suprakas Sinha Ray

1 May 2014 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
ASAline Simo
Aline Simo
BMBonex Mwakikunga
Bonex Mwakikunga
BSBertrand T. Sone
Bertrand T. Sone
BJBasil Julies
Basil Julies
RMReginaldt Madjoe
Reginaldt Madjoe
MMMalik Maaza
Malik Maaza

17 December 2019 in Diagnostics
Verified
Journal Article
Open access
PDF file
Valentine SaasaValentine Saasa
Valentine Saasa
MBMervyn Beukes
Mervyn Beukes
YLYolandy Lemmer
Yolandy Lemmer
BMBonex Mwakikunga
Bonex Mwakikunga
Analysis of volatile organic compounds in the breath for disease detection and monitoring has gained momentum and clinical significance due to its rapid test results and non-invasiveness, especially for diabetes mellitus (DM). Studies have suggested that breath gases, including acetone, may be related to simultaneous blood glucose (BG) and blood ketone levels in adults with types 2 and 1 diabetes. Detecting altered concentrations of ketones in the breath, blood and urine may be crucial for the diagnosis and monitoring of diabetes mellitus. This study assesses the efficacy of a simple breath test as a non-invasive means of diabetes monitoring in adults with type 2 diabetes mellitus. Human breath samples were collected in Tedlar™ bags and analyzed by headspace solid-phase microextraction and gas chromatography-mass spectrometry (HS-SPME/GC-MS). The measurements were compared with capillary BG and blood ketone levels (β-hydroxybutyrate and acetoacetate) taken at the same time on a single visit to a routine hospital clinic in 30 subjects with type 2 diabetes and 28 control volunteers. Ketone bodies of diabetic subjects showed a significant increase when compared to the control subjects; however, the ketone levels were was controlled in both diabetic and non-diabetic volunteers. Worthy of note, a statistically significant relationship was found between breath acetone and blood acetoacetate (R = 0.89) and between breath acetone and β-hydroxybutyrate (R = 0.82).