Guillermo Ángel Cortela

Dr. Guillermo Ángel Cortela

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Measurement
Verified
Journal Article
Closed access
JJJosé Francisco Silva Costa Júnior
José Francisco Silva Costa Júnior
GCGuillermo Ángel Cortela
Guillermo Ángel Cortela
LMLuis E. Maggi
Luis E. Maggi
TRTiago F.D. Rocha
Tiago F.D. Rocha
WPWagner Coelho De Albuquerque Pereira
Wagner Coelho De Albuquerque Pereira
AAAndré V. Alvarenga
André V. Alvarenga

1 August 2014 in Ultrasonics
Verified
Journal Article
Closed access
CTCesar Teixeira
Cesar Teixeira
AAA.V. Alvarenga
A.V. Alvarenga
GCGuillermo Ángel Cortela
Guillermo Ángel Cortela
MKM.A. von Krüger
M.A. von Krüger
WPW.C.A. Pereira
W.C.A. Pereira

1 March 2020 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
GCGuillermo Ángel Cortela
Guillermo Ángel Cortela
CNCarlos A. Negreira
Carlos A. Negreira
WPWagner Coelho De Albuquerque Pereira
Wagner Coelho De Albuquerque Pereira
Stability and duration of ultrasonic phantoms are still subjects of research. This work presents a tissue-mimicking material (TMM) to evaluate high-intensity therapeutic ultrasound (HITU) devices, composed of gellan gum (matrix), microparticles (scatterers), and chemicals. The ultrasonic velocity and attenuation coefficient were characterized as a function of temperature (range 20 °C–85 °C). The nonlinear parameter B/A was determined by the finite amplitude insertion substitution (FAIS) method, and the shear modulus was determined by a transient elastography technique. The thermal conductivity and specific heat were determined by the line source method. The attenuation was stable for 60 days, and in an almost linear frequency dependence (0.51f0.96 dB cm−1), at 20 °C (1–10 MHz). All other evaluated physical parameters are also close to typical soft tissue values. Longitudinal ultrasonic velocities were between 1.49 and 1.75 mm μs−1, the B/A parameter was 7.8 at 30 °C, and Young's modulus was 23.4 kPa. The thermal conductivity and specific heat values were 0.7 W(m K)−1 and 4.7 kJ(kg K)−1, respectively. Consistent temperature increases and thermal doses occurred under identical HITU exposures. Low cost, longevity, thermal stability, and thermal repeatability make TMM an excellent material for ultrasonic thermal applications. The TMM developed has the potential to assess the efficacy of hyperthermia devices and could be used to adjust the ultrasonic emission of HITU devices.

1 January 2015 in Physics Procedia
Verified
Journal Article
Open access
GCGuillermo Ángel Cortela
Guillermo Ángel Cortela
NBN. Benech
N. Benech
WPW.C.A. Pereira
W.C.A. Pereira
CNC. Negreira
C. Negreira
Stability and duration of ultrasonic (US) Phantoms are still a subject of research. We present a study of acoustic and mechanical properties for polyvinyl chloride plastisol (PVCP) with graphite powder (at 2% in weight) used to construct tissue-like phantoms in the temperature range of 20-45C. PVCP is a new material in the field of US phantoms and has longer duration and stability than the conventional organic mimicking materials. Longitudinal US velocity and attenuation were measured at 1MHz by the standard transmission method. Shear velocity was obtained by 1-D transient elastography. The extreme values for each of the parameters were obtained at 20C and 45C. They are: 1501.5±0.7 m/s and 1331.8±0.3 m/s for longitudinal US velocity; 0.46±0.03dB/cm and 0.94±0.09dB/cm for attenuation; and 8.4±1.2 m/s and 1.7±0.8 m/s for Shear velocity. Specific heat measured with a calorimeter and thermal conductivity measured by the method of hot plates were, respectively, 2.65±0.51J/(kgC) and 0.091±0.013J/(s°Cm), both at 22°C. For 2% of graphite powder, the parameter ranges were compatible to biological tissue ones and therefore, the same phantom can simulate different conditions only by changing its temperature. Other graphite percentages are to be tested to simulate parameter values of pathological conditions like nodules, calcification, fibrosis, etc. The phantom did not suffer from dehydration and is easy to be built in several different geometries

1 January 2013 in Proceedings of Meetings on Acoustics
Verified
Conference Paper
Closed access
GCGuillermo Ángel Cortela
Guillermo Ángel Cortela
LMLuis E. Maggi
Luis E. Maggi
MKMarco A. Kruger
Marco A. Kruger
CNCarlos A. Negreira
Carlos A. Negreira
CPC.A.Wagner Pereira
C.A.Wagner Pereira
Biological phantoms are very useful for controlled experiments on biomedical ultrasound. Nevertheless they are normally made of materials with short time-duration (organic materials). We have been studying the ultrasonic properties of test-blocks made of polyvinyl chloride-plastisol (PVCP) that are very stable in time. In this work we analyzed ultrasonic (US) attenuation and speed at 1MHz, as a function of temperature (20 to 40°C) of four phantoms made with PVCP and different concentrations of graphite powder and made with different cooking temperature, using the classical US transmission method. US speed diminished almost linearly as temperature increased. In general attenuation lied between 0.73 and 0.09 dB/cm, but presenting a more complex behavior. For graphite concentrations of 1%, attenuation was lower than for 0% and for the other two phantoms (2 and 5% concentrations) attenuation was higher. This behavior can be perhaps due to the fact that the fabrication temperature for 1% was 140°C and for the other was 170°C. Although the standard recipe is 170°C, we observed that phantoms made of smaller cooking temperatures may add in adjusting the attenuation values and it is a very useful property to mimic different biological tissues. We are now working on multilayer phantoms of PVCP.

1 January 2018 in Ultrasonics
Verified
Journal Article
Closed access
GCGuillermo Ángel Cortela
Guillermo Ángel Cortela
WPWagner C.A. Pereira
Wagner C.A. Pereira
CNCarlos A. Negreira
Carlos A. Negreira