Thomas E. Winkler

Dr. Thomas E. Winkler

Institute of Microtechnology & Center of Pharmaceutical Engineering, Technische Universität Braunschweig, 38106 Braunschweig, Germany
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2019 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
EZErica Zeglio
Erica Zeglio
ARAlexandra L. Rutz
Alexandra L. Rutz
Thomas E. WinklerThomas E. Winkler
Thomas E. Winkler
GMGeorge Malliaras
George Malliaras
AHAnna Herland
Anna Herland

1 September 2023 in APL Bioengineering
Verified
Journal Article
Open access
PDF file
DYDavid Yogev
David Yogev
TGTomer Goldberg
Tomer Goldberg
AAAmir Arami
Amir Arami
STShai Tejman-Yarden
Shai Tejman-Yarden
Thomas E. WinklerThomas E. Winkler
Thomas E. Winkler
BMBen Maoz
Ben Maoz
Implantable sensors have revolutionized the way we monitor biophysical and biochemical parameters by enabling real-time closed-loop intervention or therapy. These technologies align with the new era of healthcare known as healthcare 5.0, which encompasses smart disease control and detection, virtual care, intelligent health management, smart monitoring, and decision-making. This review explores the diverse biomedical applications of implantable temperature, mechanical, electrophysiological, optical, and electrochemical sensors. We delve into the engineering principles that serve as the foundation for their development. We also address the challenges faced by researchers and designers in bridging the gap between implantable sensor research and their clinical adoption by emphasizing the importance of careful consideration of clinical requirements and engineering challenges. We highlight the need for future research to explore issues such as long-term performance, biocompatibility, and power sources, as well as the potential for implantable sensors to transform healthcare across multiple disciplines. It is evident that implantable sensors have immense potential in the field of medical technology. However, the gap between research and clinical adoption remains wide, and there are still major obstacles to overcome before they can become a widely adopted part of medical practice.

28 July 2011 in Physical Review B
Verified
Journal Article
Closed access
ABAlberta Bonanni
Alberta Bonanni
MSMaciej Sawicki
Maciej Sawicki
TDT. Devillers
T. Devillers
WSW. Stefanowicz
W. Stefanowicz
BFB. Faina
B. Faina
TDT. Dietl
T. Dietl
The sign, magnitude, and range of the exchange couplings between pairs of Mn ions is determined for (Ga,Mn)N and (Ga,Mn)N:Si with x≲3%. The samples have been grown by metalorganic vapor phase epitaxy and characterized by secondary-ion mass spectroscopy; high-resolution transmission electron microscopy with capabilities allowing for chemical analysis, including the annular dark-field mode and electron energy loss spectroscopy; high-resolution and synchrotron x-ray diffraction; synchrotron extended x-ray absorption fine-structure; synchrotron x-ray absorption near-edge structure; infrared optics; and electron spin resonance. The results of high-resolution magnetic measurements and their quantitative interpretation have allowed us to verify a series of ab initio predictions on the possibility of ferromagnetism in dilute magnetic insulators and to demonstrate that the interaction changes from ferromagnetic to antiferromagnetic when the charge state of the Mn ions is reduced from 3+ to 2+. DOI: http://dx.doi.org/10.1103/PhysRevB.84.035206 ©2011 American Physical Society

29 December 2016 in Analytical Chemistry
Verified
Journal Article
Open access
EKEunkyoung Kim
Eunkyoung Kim
Thomas E. WinklerThomas E. Winkler
Thomas E. Winkler
CKChristopher Kitchen
Christopher Kitchen
MKMijeong Kang
Mijeong Kang
GBGeorge Banis
George Banis
GPGregory Payne
Gregory Payne
Oxidative stress is implicated in many diseases yet no simple, rapid, and robust measurement is available at the point-of-care to assist clinicians in detecting oxidative stress. Here, we report results from a discovery-based research approach in which a redox mediator is used to probe serum samples for chemical information relevant to oxidative stress. Specifically, we use an iridium salt (K2IrCl6) to probe serum for reducing activities that can transfer electrons to iridium and thus generate detectable optical and electrochemical signals. We show that this Ir-reducing assay can detect various biological reductants and is especially sensitive to glutathione (GSH) compared to alternative assays. We performed an initial clinical evaluation using serum from 10 people diagnosed with schizophrenia, a mental health disorder that is increasingly linked to oxidative stress. The measured Ir-reducing capacity was able to discriminate people with schizophrenia from healthy controls (p < 0.005), and correlations were observed between Ir-reducing capacity and independent measures of symptom severity.

2 March 2020 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
Thomas E. WinklerThomas E. Winkler
Thomas E. Winkler
MFMichael Feil
Michael Feil
ESEva F. G. J. Stronkman
Eva F. G. J. Stronkman
IMIsabelle Matthiesen
Isabelle Matthiesen
AHAnna Herland
Anna Herland
High costs are a key challenge in “democratization” of organ-chip research. We present a low-resource barrier-on-chip based on tape, and use it to model small intestine and its response to chili peppers (capsaicinoids).

1 September 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MKMijeong Kang
Mijeong Kang
EKEunkyoung Kim
Eunkyoung Kim
Thomas E. WinklerThomas E. Winkler
Thomas E. Winkler
GBGeorge Banis
George Banis
YLYi Liu
Yi Liu
GPGregory Payne
Gregory Payne