The proposed work aims at the accurate detection and classification of various single and multiple power quality (PQ) disturbances. To this end, a modified optimal fast discrete Stockwell transform (ST) with random forests (RF) classifier-based PQ detection framework has been proposed in this paper. In modified ST, a single signal-dependent window is introduced, with optimally selected window parameters via energy concentration maximization based constraint optimization. As a result of which accurate time-frequency localization of various PQ events is achieved, with sharper energy concentration. In classification stage, the proposed PQ framework utilizes the RF-based classifier, which follows the bagging approach by random selection of features and data points, at each node, to train the classifier. Decision stumps are used as weak classifiers, and using a simple majority voting of these decision stumps, RF builds a strong classifier. The RF gives less variance and less bias estimation due to injection of randomness into the training phase, and its performance is found to be reasonably immune to input parameter selection. As a result of this, the classification results of the proposed PQ framework are found to be very accurate and quite insensitive to the presence of noise in the data. Various test cases are presented in this paper to clearly demonstrate the superiority of the proposed scheme. The proposed approach has also been tested on real field data and very promising results have been obtained.
8 February 2018 in IEEE Transactions on Industrial Electronics
Distribution-level signals are often contaminated with harmonics and noise, along with dynamic conditions like frequency deviations. This paper proposes an empirical wavelet transform (EWT) based M-class distribution-level phasor estimation technique under such polluted and dynamic conditions. The capability of the EWT of extracting different frequency components present in the signal makes it suitable for distribution-level phasor estimation. However, the empirical wavelet filters are designed on the basis of the Fourier spectrum of the signal, which, inturn suffers from a spectral leakage problem at off-nominal frequencies. To avoid the errors arising due to spectral leakage, a sample value adjustment based prefiltering technique is employed. The effectiveness of the proposed estimator is demonstrated on various simulated signals, field-data, and real-time signals obtained from the hardware implementation setup. The proposed algorithm is found to be least affected by the presence of dc components, harmonics, and noise. The use of a fixed window size and fixed sampling frequency makes it suitable for synchronization with GPS clocks. The proposed scheme is also able to provide an accurate harmonic phasor estimation.
30 October 2019 in IEEE Transactions on Industrial Informatics
This paper proposes a simple yet effective statistical parameters based passive islanding scheme. The proposed scheme relies only the voltage data, measured at the point of common coupling (PCC), and is comprised of three stages. The Stage-1 quickly computes what is termed as mean based coarse islanding detection (MID), Stage-2 computes the decaying DC detector (DDCD), and 3) finally, MID is used in conjunction with DDCD as per the statistical digital relay logic (SRDL) is devised in Stage-3 to distinguish between islanding events from non islanding events. Various tests are investigated on the Banshee's industrial Microgrid (MG), modelled in the Real Time Digital Simulator (RTDS), on the basis of the IEEE-1547, UL 1741 standards. The validation of the proposed islanding detection methodology (PIDM) in RTDS platform ensures the viability of the proposed scheme in practical systems. The test results reveal that the PIDM can detect islanding within 2 cycles, and results in a very small non detection zone (NDZ). Moreover, the scheme can very well be used for single-phase MG too as it relies only on the single phase voltage information.
In September 2020, the Federal Energy Regulatory Commission (FERC) released Order 2222, which opens wholesale markets to small-capacity distributed energy resources (DERs), recognizing their potential in improving operational efficiency by providing bulk grid services. Therefore, a co-simulation capability that can connect transmission and distribution (T&D) simulations and evaluate the impacts of DER provision of bulk grid services is needed. In this paper, we present a new integrated T&D co-simulation platform that incorporates T&D system simulators, DER aggregator/group strategies, and a co-simulation coordinator. Industry-standard communication protocols are employed to mimic real-world conditions. Secondary frequency regulation is selected as the representative bulk grid service, and we simulate the responses of DERs to the frequency regulation signals. The simulation results for a solar-rich distribution feeder in Colorado, USA, demonstrate how the T&D co-simulation setup is used to evaluate the contributions of DERs to minimize the bulk grid frequency deviation.
In recent years, cyberattacks - along with physical faults - have become an increasing factor causing system failures, especially in DER (Distributed Energy Resources) systems. In addition, according to the literature, a number of faults have been reported to remain undetected. Consequently, unlike anomaly detection works that only identify abnormalities, differentiating undetected faults and cyberattacks is a challenging task. Although several works have studied this problem, they crucially fall short of achieving an accurate distinction due to the reliance on physical laws or physical measurements. To resolve this issue, the industry typically conducts an integrated analysis with physical measurements and cyberspace information. Nevertheless, this industry approach consumes a significant amount of time due to the manual efforts required in the analysis. In this work, we focus on addressing these crucial gaps by proposing a non-trivial approach of distinguishing undetected faults and cyberattacks in DER systems. Specifically, first, a special kind of dependency graph is constructed using a novel virtual physical variable-oriented taint analysis (PVOTA) algorithm. Then, the graph is simplified using an innovative node pruning technique, which is based on a set of context-dependent operations. Next, a set of patterns capturing domain-specific knowledge is derived to bridge the semantic gaps between the cyber and physical sides. Finally, these patterns are matched to the relevant events that occurred during failure incidents, and possible root causes are concluded based on the pattern matching results. In the end, the efficacy of our proposed automatic integrated analysis is evaluated through four case studies covering failure incidents caused by the FDI attack, undetected faults, and memory corruption attacks.