Fibrous air filters are common devices used to remove airborne particles. Their performance is typically measured through their resistance to airflow and captured particle mass. Models describing the evolution of filter performance have been heavily researched; however, the need for improvement remains. Experimental work is irreplaceable in the development of high-fidelity models, yet the estimation of necessary variables is not trivial and may be influenced by selected measurement instruments and analysis methodologies. Therefore, the purpose of this work is to propose a framework to investigate the response of common aerosol measurement instruments, their corresponding analysis methodologies, and the application of their data. A Scanning Mobility Particle Sizer (SMPS) and Laser Aerosol Spectrometer (LAS) were selected for consideration, and their recorded data were compared against baseline measurements. The results of the experiments indicated that the SMPS and LAS yielded a ratio of estimated mass concentrations to the baseline mass concentrations of approximately 1.175 and 0.749, respectively. Regarding the SMPS, it was suggested that the measurable size range, application of a coverage factor, dynamic shape factor, and association between the curve fits and histograms were influential in the final estimates. For the LAS, the application of a curve fit, its association to the histograms, and the selection of the sampling periods were influential. Considering the results, the impact of these factors may not be considered negligible and may skew reproducibility between studies and fossilize confounding factors. Therefore, the proposed methodologies are useful in addressing potential errors in data collection and analysis.

8 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
Erich Martinez-MartinErich Martinez-Martin
Erich Martinez-Martin
Alta KnizleyAlta Knizley
Alta Knizley
Small modular reactors (SMRs) offer firm low-carbon heat and power, and data centers concentrate large, continuous electrical and cooling loads. Transparent tools for screening their thermal integration are scarce. To the authors’ knowledge, this paper develops the first steady-state thermodynamic framework that couples SMR steam extraction, solar thermal input, and recovered data-center liquid-cooling heat through a single mixing-tank thermal bus serving both an absorption chiller and an organic Rankine cycle (ORC). The framework’s novelty is in its focus on the structural level rather than the component level. Two consistency requirements are built into its equations. First, the data-center control volume closes exactly, so that recovered heat reduces the residual cooling demand and heat removal equals IT dissipation. Second, delivered cooling is credited identically in every configuration compared, so that apparent gains cannot arise from asymmetric accounting. The framework identifies the governing mechanism of the architecture: a small 120 °C extraction stream (1.01% of core thermal power at the activation bound) unlocks the larger 70 °C recovered stream, which cannot drive the chiller alone. At the margin-constrained design point (2.93% extraction), direct liquid recovery removes 20.9 MWth, absorption cooling serves the remaining 16.2 MWth, and net electricity is 5.8 MWe above the all-electric reference. An itemized estimate places the integration-specific parasitic loads at 0.6–1.5 MWe (central value 1.0 MWe), which reduces the increment over the liquid-cooled non-integrated reference from +0.5 MWe (gross) to approximately −0.5 MWe (net). A 20,000-sample Monte Carlo analysis across seven uncertain parameters shows the net-of-parasitics gain over the all-electric reference is positive with 92% probability (median +4.1 MWe), while the increment over the non-integrated reference is positive with only 29% probability. A compact exergy inventory attributes 7.1 MW of destruction to the recovery train (process heat exchanger 2.0, mixing 1.2, ORC 2.0, chiller 2.0). The architecture’s robust value therefore lies in thermally driven cooling and the productive use of recovered heat, not in net energy. The framework is a screening tool rather than a validated plant model; a companion study populates it with published plant, climate, and equipment data.