Songsong Xiong

Songsong Xiong


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ZCZhenshi Chen
Zhenshi Chen
SXSongsong Xiong
Songsong Xiong
SGShecheng Gao
Shecheng Gao
HZHui Zhang
Hui Zhang
LWLei Wan
Lei Wan
ZLZhaohui Li
Zhaohui Li
A miniaturized tip Fabry-Perot interferometer (tip-FPI) is proposed for high-temperature sensing. It is simply fabricated for the first time by splicing a short length of microfiber (MF) to the cleaved end of a standard single mode fiber (SMF) with precise control of the relative cross section position. Such a MF acts as a Fabry-Perot (FP) cavity and serves as a tip sensor. A change in temperature modifies the length and refractive index of the FP cavity, and then a corresponding change in the reflected interference spectrum can be observed. High temperatures of up to 1000 °C are measured in the experiments, and a high sensitivity of 13.6 pm/°C is achieved. This compact sensor, with tip diameter and length both of tens of microns, is suitable for localized detection, especially in harsh environments.

17 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
HZHui Zhang
Hui Zhang
SGShecheng Gao
Shecheng Gao
YLYunhan Luo
Yunhan Luo
ZCZhenshi Chen
Zhenshi Chen
SXSongsong Xiong
Songsong Xiong
ZLZhaohui Li
Zhaohui Li
A liquid-filled D-shaped fiber (DF) cavity serving as an in-fiber Mach–Zehnder interferometer (MZI) has been proposed and experimentally demonstrated for temperature sensing with ultrahigh sensitivity. The miniature MZI is constructed by splicing a segment of DF between two single-mode fibers (SMFs) to form a microcavity (MC) for filling and replacement of various refractive index (RI) liquids. By adjusting the effective RI difference between the DF and MC (the two interference arms), experimental and calculated results indicate that the interference spectra show different degrees of temperature dependence. As the effective RI of the liquid-filled MC approaches that of the DF, temperature sensitivity up to −84.72 nm/°C with a linear correlation coefficient of 0.9953 has been experimentally achieved for a device with the MC length of 456 μm, filled with liquid RI of 1.482. Apart from ultrahigh sensitivity, the proposed MCMZI device possesses additional advantages of its miniature size and simple configuration; these features make it promising and competitive in various temperature sensing applications, such as consumer electronics, biological treatments, and medical diagnosis.

1 January 2011
Verified
Conference Paper
Closed access
JFJianguo Fu
Jianguo Fu
SXSongsong Xiong
Songsong Xiong
WLWeiping Liu
Weiping Liu
LYLiang Yang
Liang Yang
XDXuchang Ding
Xuchang Ding
YLYongqing Liao
Yongqing Liao