Thermal runaway propagation (TRP) is a primary safety issue in lithium-ion battery (LIB) applications, and the use of a thermal barrier is considered to be a promising solution for TRP prevention. However, the operating conditions of the battery are extremely complicated, such as fast charging, low-temperature heating and thermal runaway. To date, there is no consistent answer as to how to choose the appropriate thermal barrier for such a complicated working environment. In this study, the characteristics of hydrogel based on sodium polyacrylate are explored, and the impact of thermal barrier area on TRP is investigated through experiments. Due to the prismatic battery structure, thermal barriers placed between cells are designed with different areas (148 × 98 mm, 128 × 88 mm, and 108 × 78 mm). The results indicate that test 1 without a placed thermal barrier quickly completes the TRP process, and the thermal runaway (TR) behavior is more violent. With a thermal barrier that does not have full area coverage placed between cells (test 2 and test 3), the propagation time is prolonged, but TRP still occurs. Compared with test 1, the triggered temperature of T2 F (the front surface of cell 2) is reduced by 207.6 °C and 295.2 °C, respectively. The complete area coverage thermal barrier successfully prevents TRP, and the T2 F of cell 2 only reaches 145.4 °C under the phase change by the hydrogel. This study may suggest a safety design for battery modules and prevent propagation among batteries.
The combustion and explosion characteristics of lithium-ion battery vent gas is a key factor in determining the fire hazard of lithium-ion batteries. Investigating the combustion and explosion hazards of lithium-ion batteries vent gas can provide guidance for rescue and protection in explosion accidents in energy storage stations and new energy vehicles, thereby promoting the application and development of lithium-ion batteries. Based on this understanding and combined with previous research on gas production from lithium-ion batteries, this article conducted a study on the combustion and explosion risks of vent gas from thermal runaway of 18650 LFP batteries with different states of charge (SOCs). The explosion limit of mixed gases affected by carbon dioxide inert gas is calculated through the "elimination" method, and the Chemkin-Pro software is used to numerically simulate the laminar flame speed and adiabatic flame temperature of the battery vent gas. And the concentration of free radicals and sensitivity coefficients of major elementary reactions in the system are analyzed to comprehensively evaluate the combustion explosion hazard of battery vent gas. The study found that the 100% SOC battery has the lowest explosion limit of the vent gas. The inhibitory elementary reaction sensitivity coefficient in the reaction system is lower and the concentration of free radicals is higher. Therefore, it has the maximum laminar flame speed and adiabatic flame temperature. The combustion and explosion hazard of battery vent gas increases with the increase of SOC, and the risk of explosion is the greatest and most harmful when SOC reaches 100%. However, the related hazards decrease to varying degrees with overcharging of the battery. This article provides a feasible method for analyzing the combustion mechanism of vent gas from lithium-ion batteries, revealing the impact of SOC on the hazardousness of battery vent gas. It provides references for the safety of storage and transportation of lithium-ion batteries, safety protection of energy storage stations, and the selection of related fire extinguishing agents.
In this study, the fire behavior variation of unenergized polyvinyl chloride (PVC) copper wires subjected to overload with different currents was investigated by a cone calorimeter. Overload currents were selected from 1 times safe-rated current (Ie) to 3.5 times Ie to obtain tested sample wires. The mass fraction, time to ignition (TTI), heat release rate (HRR), gas emission, and residue were measured. If the current flowing through the wire increased up to 3.5 times Ie, the TTI of this unenergized wire increased drastically and the peak HRR (pHRR) decreased notably so that the flame growing index (FGI) reduced considerably. When the wire carried less than three times Ie, the FGI remained stable. For all overloaded PVC copper wires, the increase in the heat flux resulted in a higher pHRR and a lower burning duration. However, regardless of the external heat flux exposure, the FGI of copper wires overloaded at 3.5 times Ie was lower than that of copper wires carrying less than other times Ie. Moreover, the consumption of O2 and generation of CO2 as the heat flux varied were consistent with that of the HRR. Opposed to expectation, the flame propagation of unenergized PVC copper wires would decline in a fire, if the wire has been damaged by overload with some currents.