Ziyang Li

Ziyang Li

School of physics, Harbin Institute of Technology, Harbin, Heilongjiang, China
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2023 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
ZLZiyang Li
Ziyang Li
XZXuyang Zhou
Xuyang Zhou
YWYiran Wang
Yiran Wang
GHGuancheng Huang
Guancheng Huang
SLShutian Liu
Shutian Liu
Zhengjun LiuZhengjun Liu
Zhengjun Liu

3 February 2025 in Optics Letters
Verified
Journal Article
Closed access
ZLZiyang Li
Ziyang Li
XZXuyang Zhou
Xuyang Zhou
YWYiran Wang
Yiran Wang
YLYutong Li
Yutong Li
GHGuancheng Huang
Guancheng Huang
Zhengjun LiuZhengjun Liu
Zhengjun Liu
Lens-free on-chip microscopy (LFOCM) is a high-throughput computational imaging technique that enables high-resolution, label-free imaging without requiring complex optical systems. However, LFOCM encounters significant challenges in achieving high-resolution reconstructions due to noise accumulation. We propose a high-fidelity LFOCM method that integrates pixel super-resolution (PSR) with dynamic dual-channel noise separation (DCNS). This approach simultaneously separates the amplitude and phase noise during the reconstruction process, thereby improving noise robustness and enhancing the dynamic range of quantitative amplitude and phase imaging. Experimental validation across various sample types demonstrated the effectiveness of our method. DCNS achieves a resolution that exceeds 34.1% of the Nyquist–Shannon sampling limit, with a full field of view (FOV) of 28.6 mm2, improving the dynamic range of phase reconstruction and effectively suppressing artifacts that degrade the reconstruction quality, thus resolving the trade-off between noise reduction and resolution.

19 October 2025 in Laser & Photonics Reviews
Verified
Journal Article
Closed access
ZLZiyang Li
Ziyang Li
XZXuyang Zhou
Xuyang Zhou
SGSida Gao
Sida Gao
GHGuancheng Huang
Guancheng Huang
ZQZiling Qiao
Ziling Qiao
Zhengjun LiuZhengjun Liu
Zhengjun Liu

18 August 2025 in Applied Physics Letters
Verified
Journal Article
Closed access
ZLZiyang Li
Ziyang Li
SGSida Gao
Sida Gao
XZXuyang Zhou
Xuyang Zhou
YWYiran Wang
Yiran Wang
GHGuancheng Huang
Guancheng Huang
Zhengjun LiuZhengjun Liu
Zhengjun Liu
Lensless on-chip microscopy (LOCM) has emerged as a research focus in computational imaging due to its compact structure and high-throughput imaging capabilities. However, precise calibration of misalignments between axial holograms is challenging, and these errors accumulate and magnify during the phase retrieval process, limiting the imaging resolution and detail fidelity. We propose a pixel-super-resolved LOCM via precision-enhanced dynamic registration and complex-constrained phase retrieval. The approach incorporates a dynamic registration mechanism in the iterative reconstruction process, effectively suppressing global misalignment errors. The introduction of physical constraints improves the convergence stability and further enhances the fidelity. Experimental results across different sample types demonstrate a 1.78-fold improvement in spatial resolution beyond the Nyquist–Shannon sampling limit across a full field of view of 28.6 mm2, with the minimum resolvable size reaching 775 nm. This method achieves superior performance in resolving intricate structural details, offering an effective solution for high-fidelity lensless imaging.

25 November 2024 in Optics Letters
Verified
Journal Article
Closed access
YWYiran Wang
Yiran Wang
YLYutong Li
Yutong Li
ZLZiyang Li
Ziyang Li
XZXuyang Zhou
Xuyang Zhou
YJYu Ji
Yu Ji
SLShutian Liu
Shutian Liu
Structured illumination microscopy (SIM) is a widely applied fluorescence super-resolution imaging technique. It can also serve as high-throughput imaging in coherent imaging systems. However, coherent SIM requires additional qualitative/quantitative phase imaging methods to acquire phase information. This paper proposes a structured illumination microscopy technique based on the Kramers–Kronig relations (KK-SIM) that achieves quantitative phase imaging without the need for extra technical assistance and relies solely on the spatial-domain intensity images reconstructed through conventional SIM. KK-SIM utilizes a non-iterative approach to recover intensity into amplitude and phase, maintaining SIM’s high acquisition speed and reconstruction efficiency. Our work enables high-throughput quantitative phase imaging using conventional SIM experimental setups and data post-processing, making SIM suitable for label-free, noninvasive dynamic observation.

24 September 2023 in Journal of Biophotonics
Verified
Journal Article
Closed access
XZXuyang Zhou
Xuyang Zhou
ZLZiyang Li
Ziyang Li
ZQZiling Qiao
Ziling Qiao
YWYiran Wang
Yiran Wang
GHGuancheng Huang
Guancheng Huang
Zhengjun LiuZhengjun Liu
Zhengjun Liu