Thomas Just Sørensen

Dr. Thomas Just Sørensen

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2018 in Science Advances
Verified
Journal Article
Open access
PDF file
MCMiguel R. Carro-Temboury
Miguel R. Carro-Temboury
RARiikka Arppe
Riikka Arppe
TVTom Vosch
Tom Vosch
TSThomas Just Sørensen
Thomas Just Sørensen
Secure data encryption relies heavily on one-way functions, and copy protection relies on features that are difficult to reproduce. We present an optical authentication system based on lanthanide luminescence from physical one-way functions or physical unclonable functions (PUFs). They cannot be reproduced and thus enable unbreakable encryption. Further, PUFs will prevent counterfeiting if tags with unique PUFs are grafted onto products. We have developed an authentication system that comprises a hardware reader, image analysis, and authentication software and physical keys that we demonstrate as an anticounterfeiting system. The physical keys are PUFs made from random patterns of taggants in polymer films on glass that can be imaged following selected excitation of particular lanthanide(III) ions doped into the individual taggants. This form of excitation-selected imaging ensures that by using at least two lanthanide(III) ion dopants, the random patterns cannot be copied, because the excitation selection will fail when using any other emitter. With the developed reader and software, the random patterns are read and digitized, which allows a digital pattern to be stored. This digital pattern or digital key can be used to authenticate the physical key in anticounterfeiting or to encrypt any message. The PUF key was produced with a staggering nominal encoding capacity of 73600. Although the encoding capacity of the realized authentication system reduces to 6 × 10104, it is more than sufficient to completely preclude counterfeiting of products.

16 January 2019 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
RARiikka Arppe-Tabbara
Riikka Arppe-Tabbara
MTMohammad Tabbara
Mohammad Tabbara
TSThomas Just Sørensen
Thomas Just Sørensen

20 December 2012 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
RRRyan M. Rich
Ryan M. Rich
DSDorota L. Stankowska
Dorota L. Stankowska
BMBadri P. Maliwal
Badri P. Maliwal
TSThomas Just Sørensen
Thomas Just Sørensen
BLBo W. Laursen
Bo W. Laursen
RFRafal Fudala
Rafal Fudala

12 January 2015 in Chemical Science
Verified
Journal Article
Open access
PDF file
TSThomas Just Sørensen
Thomas Just Sørensen
AKAlan M. Kenwright
Alan M. Kenwright
SFStephen Faulkner
Stephen Faulkner
Heterometallic lanthanide complexes can display a ratiometric response to oxygen concentrations.

17 September 2018 in Accounts of Chemical Research
Verified
Journal Article
Closed access
TSThomas Just Sørensen
Thomas Just Sørensen
SFStephen Faulkner
Stephen Faulkner

24 June 2013 in Physical Chemistry Chemical Physics
Verified
Journal Article
Open access
PDF file
KKKasper Skov Kjær
Kasper Skov Kjær
TDTim B. van Driel
Tim B. van Driel
JKJan Kehres
Jan Kehres
KHKristoffer Haldrup
Kristoffer Haldrup
DKDmitry Khakhulin
Dmitry Khakhulin
MNMartin M. Nielsen
Martin M. Nielsen
In time-resolved laser pump, X-ray probe wide-angle X-ray scattering experiments on systems in solution the structural response of the system is accompanied by a solvent response. The solvent response is caused by reorganization of the bulk solvent following the laser pump event, and in order to extract the structural information of the solute, the solvent response has to be treated. Methodologies capable of doing so include both theoretical modelling and experimental determination of the solvent response. In the work presented here, we have investigated how to obtain a reproducible solvent response—the solvent term—experimentally when applying laser pump, X-ray probe time-resolved wide-angle X-ray scattering. The solvent term describes difference scattering arising from the structural response of the solvent to changes in the hydrodynamic parameters: pressure, temperature and density. We present results based on NIR and dye mediated solvent heating, and demonstrate that the solvent response is independent of the heating method. The NIR heating is shown to be rendered unusable by higher order effects under certain experimental conditions, while the dye mediated solvent heating is demonstrated to exhibit first order behaviour with respect to the amount of energy deposited in the solution. We introduce a standardized method for recording solvent responses in laser pump, X-ray probe time-resolved X-ray wide-angle scattering experiments by using dye mediated solvent heating. Furthermore, we have generated a library of solvent terms, which can be used to describe the solvent term in any TRWAXS experiment, and made it available online.