Background: Overuse of short-acting β2-agonists (SABA) may indicate poor asthma control and adverse health outcomes. Contemporary population-based data on use, risk factors and impact of SABA (over)use on asthma exacerbations and mortality are scarce, prompting initiation of the global SABINA (SABA use IN Asthma) programme.Methods: By linking data from Swedish national registries, asthma patients aged 12–45 years with two or more collections of drugs for obstructive lung disease during 2006–2014 were included. SABA overuse was defined as collection of more than two SABA canisters in a 1-year baseline period following inclusion. SABA use was grouped into 3–5, 6–10 and ≥11 canisters per baseline-year. Cox regression was used to examine associations between SABA use and exacerbation (hospitalisations and/or oral corticosteroid claims) and mortality.Results: The analysis included 365 324 asthma patients (mean age 27.6 years; 55% female); average follow-up was 85.4 months. 30% overused SABA, with 21% collecting 3–5 canisters per year, 7% collecting 6–10 canisters per year and 2% collecting ≥11 canisters per year. Increasing number of collected SABA canisters was associated with increased risk of exacerbation, as follows. 3–5 canisters: hazard ratio (HR) 1.26 (95% CI 1.24–1.28); 6–10 canisters: 1.44 (1.41–1.46); and ≥11 canisters: 1.77 (1.72–1.83), compared to two or fewer canisters per year. Higher SABA use was associated with incrementally increased mortality risk (2564 deaths observed), as follows. 3–5 canisters: HR 1.26 (95% CI 1.14–1.39); 6–10 canisters 1.67 (1.49–1.87); and ≥11 canisters: 2.35 (2.02–2.72) compared to two or fewer canisters per year.Conclusion: One-third of asthma patients in Sweden collected three or more SABA canisters annually. SABA overuse was associated with increased risks of exacerbation and mortality. These findings emphasise that monitoring of SABA usage should be key in improving asthma management.
In the 1990s, metered dose inhalers (MDIs) containing chlorofluorocarbons were replaced with dry-powder inhalers (DPIs) and MDIs containing hydrofluorocarbons (HFCs). While HFCs are not ozone depleting, they are potent greenhouse gases. Annual carbon footprint (CO2e), per patient were 17 kg for Relvar-Ellipta/Ventolin-Accuhaler; and 439 kg for Seretide-Evohaler/Ventolin-Evohaler. In 2017, 70% of all inhalers sold in England were MDI, versus 13% in Sweden. Applying the Swedish DPI and MDI distribution to England would result in an annual reduction of 550 kt CO2e. The lower carbon footprint of DPIs should be considered alongside other factors when choosing inhalation devices.
To prospectively analyze changes in the prevalence of insomnia and the relationship between insomnia, aging, lifestyle, and medical disorders a longitudinal population survey. a randomly selected population sample of 2,602 men (age 30–69 years) from Uppsala in Sweden. all participants answered a questionnaire on sleep disturbances, lifestyle factors, and medical disorders in 1984 and again in 1994. The prevalence of INSOMNIA was 10.3% in 1984 and 12.8% in 1994. No significant correlation was found between age and insomnia in any of the two time periods. Insomnia in 1994 was independently related to having insomnia in 1984 (OR=6.45), being overweight (BMI> 27 kg/m2) (OR=1.35), physical inactivity (OR=1.42), alcohol dependence (OR=1.75), psychiatric disorders (OR=8.27) and joint/low back disorders (OR=2.95). The number of subject with reported insomnia in 1984 but not 1994 was 149. Subjects that quit smoking during the time period had an increased likeliness of remission (OR=2.70) while men who were overweight were less likely to remit (OR=0.43). We conclude that in men insomnia is related to lifestyle factors such as obesity, physical inactivity and alcohol dependency but not to aging. Medical disorders such as joint and low back disorders and psychiatric illnesses also increase the risk of reporting insomnia. This study demonstrates the close relationship between quality of sleep and overall health status.
Objective To investigate the occurrence of pneumonia and pneumonia related events in patients with chronic obstructive pulmonary disease (COPD) treated with two different fixed combinations of inhaled corticosteroid/long acting β2 agonist. Design Observational retrospective pairwise cohort study matched (1:1) for propensity score. Setting Primary care medical records data linked to Swedish hospital, drug, and cause of death registry data for years 1999-2009. Participants Patients with COPD diagnosed by a physician and prescriptions of either budesonide/formoterol or fluticasone/salmeterol. Main outcome measures Yearly pneumonia event rates, admission to hospital related to pneumonia, and mortality. Results 9893 patients were eligible for matching (2738 in the fluticasone/salmeterol group; 7155 in the budesonide/formoterol group), yielding two matched cohorts of 2734 patients each. In these patients, 2115 (39%) had at least one recorded episode of pneumonia during the study period, with 2746 episodes recorded during 19 170 patient years of follow up. Compared with budesonide/formoterol, rate of pneumonia and admission to hospital were higher in patients treated with fluticasone/salmeterol: rate ratio 1.73 (95% confidence interval 1.57 to 1.90; P<0.001) and 1.74 (1.56 to 1.94; P<0.001), respectively. The pneumonia event rate per 100 patient years for fluticasone/salmeterol versus budesonide/formoterol was 11.0 (10.4 to 11.8) versus 6.4 (6.0 to 6.9) and the rate of admission to hospital was 7.4 (6.9 to 8.0) versus 4.3 (3.9 to 4.6). The mean duration of admissions related to pneumonia was similar for both groups, but mortality related to pneumonia was higher in the fluticasone/salmeterol group (97 deaths) than in the budesonide/formoterol group (52 deaths) (hazard ratio 1.76, 1.22 to 2.53; P=0.003). All cause mortality did not differ between the treatments (1.08, 0.93 to 1.14; P=0.59). Conclusions There is an intra-class difference between fixed combinations of inhaled corticosteroid/long acting β2 agonist with regard to the risk of pneumonia and pneumonia related events in the treatment of patients with COPD. Trial registration Clinical Trials.gov NCT01146392.
Background: Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX).Methods: A total of 71 subjects (6–60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD).Results: Success rate was high (≥ 84%) in both devices for both adults and children. The subjects represented a FENOrange of 8–147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively.Conclusion: The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children. The new hand-held device will enable the introduction of exhaled NO measurements into the primary health care.