Da He

Dr. Da He


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
HQHui Qi
Hui Qi
DHDa He
Da He
YSYuqing Sun
Yuqing Sun
YXYonggang Xing
Yonggang Xing
JWJiankun Wen
Jiankun Wen
XYXiaojian Ye
Xiaojian Ye
Background: To compare standalone oblique lateral interbody fusion (OLIF) vs. OLIF combined with posterior bilateral percutaneous pedicle screw fixation (OLIF combined) for the treatment of lumbar spondylolisthesis. Methods: This was a retrospective study of patients who underwent standalone OLIF or combined OLIF between 07/2014 and 08/2017 at two hospitals in China. Direct decompressions were not performed. Visual analog scale (VAS), Oswestry Disability Index (ODI), satisfaction rate, anterior/posterior disc heights (DH), foraminal height (FH), foraminal width (FW), cage subsidence, cage retropulsion, fusion rate, and complications were analyzed. All imaging examinations were read independently by two physicians and the mean measurements were used for analysis. Results: A total of 73 patients were included: 32 with standalone OLIF and 41 with combined OLIF. The total complication rate was 25.0% with standalone OLIF and 26.8% with combined OLIF. There were no differences in VAS and ODI scores by 2 years of follow-up, but the scores were better with standalone OLIF at 1 week and 3 months (P < 0.05). PDH and FW was smaller in the combined OLIF group compared with the standalone OLIF group before and after surgery (all P < 0.05). There were significant differences in FH before surgery and at 1 week and 3 months between the two groups (all P < 0.05), but the difference disappeared by 2 years (P = 0.111). Cage subsidence occurred in 7.3% (3/41) and 7.3% (3/41) of the patients at 3 and 24 months, respectively, in the combined OLIF group, compared with 6.3% (2/32) and 15.6% (5/32), respectively, in the standalone OLIF group at the same time points (P = 0.287). There was no cage retropulsion in both groups at 2 years. The fusion rate was 85.4%(35/41) in the combined OLIF group and 84.4% (27/32) in the standalone OLIF group at 3 months(P = 0.669). At 24 months, the fusion rate was 100.0% in the combined OLIF group and 93.8% (30/32) in the standalone OLIF group (P = 0.066). Conclusion: Standalone OLIF may achieve equivalent clinical and radiological outcomes than OLIF combined with fixation for spondylolisthesis. The rate of complications was similar between the two groups. Patients who are osteoporotic might be better undergoing combined rather than standalone OLIF. The possibilty of proof lies within a future prospective study, preferably an RCT.

1 October 2021 in Orthopaedic Surgery
Verified
Journal Article
Open access
PDF file
XHXiaoguang Han
Xiaoguang Han
GTGuo‐Qing Tang
Guo‐Qing Tang
XHXiao Han
Xiao Han
YXYong‐Gang Xing
Yong‐Gang Xing
QZQi Zhang
Qi Zhang
WTWei Tian
Wei Tian
Objective: To compare the safety and effectiveness of robot‐assisted minimally invasive transforaminal lumbar interbody fusion (Mis‐TLIF) and oblique lumbar interbody fusion (OLIF) for the treatment of single‐level lumbar degenerative spondylolisthesis (LDS).Methods: This is a retrospective study. Between April 2018 and April 2020, a total of 61 patients with single‐level lumbar degenerative spondylolisthesis and treated with robot‐assisted OLIF (28 cases, 16 females, 12 males, mean age 50.4 years) or robot‐assisted Mis‐TLIF (33 cases, 18 females, 15 males, mean age 53.6 years) were enrolled and evaluated. All the pedicle screws were implanted percutaneously assisted by the TiRobot system. Surgical data included the operation time, blood loss, and length of postoperative hospital stay. The clinical and functional outcomes included Oswestry Disability Index (ODI), Visual Analog scores (VAS) for back and leg pain, complication, and patient's satisfaction. Radiographic outcomes include pedicle screw accuracy, fusion status, and disc height. These data were collected before surgery, at 1 week, 3 months, 6 months, and 12 months postoperatively.Results: There were no significantly different results in preoperative measurement between the two groups. There was significantly less blood loss (142.4 ± 89.4 vs 291.5 ± 72.3 mL, P < 0.01), shorter hospital stays (3.2 ± 1.8 vs 4.2 ± 2.5 days, P < 0.01), and longer operative time (164.9 ± 56.0 vs 121.5 ± 48.2 min, P < 0.01) in OLIF group compared with Mis‐TLIF group. The postoperative VAS scores and ODI scores in both groups were significantly improved compared with preoperative data (P < 0.05). VAS scores for back pain were significantly lower in OLIF group than Mis‐TLIF group at 1 week (2.8 ± 1.2 vs 3.5 ± 1.6, P < 0.05) and 3 months postoperatively (1.6 ± 1.0 vs 2.1 ± 1.1, P < 0.05), but there was no significant difference at further follow‐ups. ODI score was also significantly lower in OLIF group than Mis‐TLIF group at 3 months postoperatively (22.3 ± 10.0 vs 26.1 ± 12.8, P < 0.05). There was no significant difference in the proportion of clinically acceptable screws between the two groups (97.3% vs 96.2%, P = 0.90). At 1 year, the OLIF group had a higher interbody fusion rate compared with Mis‐TLIF group (96.0% vs 87%, P < 0.01). Disc height was significantly higher in the OLIF group than Mis‐TLIF group (12.4 ± 3.2 vs 11.2 ± 1.3 mm, P < 0.01). Satisfaction rates at 1 year exceeded 90% in both groups and there was no significant difference (92.6% for OLIF vs 91.2% for Mis‐TLIF, P = 0.263).Conclusion: Robot‐assisted OLIF and Mis‐TLIF both have similar good clinical outcomes, but OLIF has the additional benefits of less blood loss, less postoperative hospital stays, higher disc height, and higher fusion rates. Robots are an effective tool for minimally invasive spine surgery.

8 December 2022 in Orthopaedic Surgery
Verified
Journal Article
Open access
JLJiahao Li
Jiahao Li
ZAZhicheng An
Zhicheng An
JWJigong Wu
Jigong Wu
YGYongchang Gao
Yongchang Gao
SLSheng Lu
Sheng Lu
YZYu Zhao
Yu Zhao
Objective: Adolescent idiopathic scoliosis (AIS) is a three‐dimensional structural deformity of the spine caused by the disruption of the biomechanical balance of the spine. However, the current biomechanical modeling and analysis methods of scoliosis cannot really describe the real state of the spine. This study aims to propose a high‐precision biomechanical modeling and analysis method that can reflect the spinal state under gravity and provide a theoretical basis for therapeutics.Methods: Combining CT and X‐ray images of AIS patients, this study constructed an adjusted three‐dimensional model and FE model of the spine corresponding to the patient's gravity position, including vertebral bodies, intervertebral discs, ribs, costal cartilage, ligaments, and facet cartilage. Then, the displacement and stress of the spine under gravity were analyzed.Results: A model of the T1‐Sacrum with 1.7 million meshes was constructed. After adding the gravity condition, the maximum displacement point was at T1 of thoracic vertebra (20.4 mm). The analysis indicates that the stress on the lower surface of the vertebral body in thoracolumbar scoliosis tended to be locally concentrated, especially on the concave side of the primary curvature's vertebral body (the maximum stress on the lower surface of T9 is 32.33 MPa) and the convex side of the compensatory curvature's vertebral body (the maximum stress on the lower surface of L5 is 41.97 MPa).Conclusion: This study provides a high‐precision modeling and analysis method for scoliosis with full consideration of gravity. The reliability of the method was verified based on patient data. This model can be used to analyze the biomechanical characteristics of patients in the treatment plan design stage.

4 November 2022 in BMC Surgery
Verified
Journal Article
Open access
PDF file
ZLZhao Lang
Zhao Lang
XHXiaoguang Han
Xiaoguang Han
MFMingxing Fan
Mingxing Fan
YLYajun Liu
Yajun Liu
DHDa He
Da He
WTWei Tian
Wei Tian
Background: To evaluate the accuracy of screw placement using the TiRobot surgical robot in the Harms procedure and to assess the clinical outcomes of this technique. Methods: This retrospective study included 21 patients with atlantoaxial instability treated by posterior atlantoaxial internal fixation (Harms procedure) using the TiRobot surgical robot between March 2016 and June 2021. The precision of screw placement, perioperative parameters and clinical outcomes were recorded. Screw placement was assessed based on intraoperative guiding pin accuracy measurements on intraoperative C-arm cone-beam computed tomography (CT) images using overlay technology and the incidence of screw encroachment identified on CT images. Results: Among the 21 patients, the mean age was 44.8 years, and the causes of atlantoaxial instability were os odontoideum (n = 11), rheumatoid arthritis (n = 2), unknown pathogenesis (n = 3), and type II odontoid fracture (n = 5). A total of 82 screws were inserted with robotic assistance. From intraoperative guiding pin accuracy measurements, the average translational and angular deviations were 1.52 ± 0.35 mm (range 1.14–2.25 mm) and 2.25° ± 0.45° (range 1.73°–3.20º), respectively. Screw placement was graded as A for 80.5% of screws, B for 15.9%, and C for 3.7%. No complications related to screw misplacement were observed. After the 1-year follow-up, all patients with a neurological deficit experienced neurological improvement based on Nurick Myelopathy Scale scores, and all patients with preoperative neck pain reported improvement based on Visual Analog Scale scores. Conclusions: Posterior atlantoaxial internal fixation using the Harms technique assisted by a 3D-based navigation robot is safe, accurate, and effective for treating atlantoaxial instability.

8 September 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
YZYunxian Zhang
Yunxian Zhang
WLWenhai Liu
Wenhai Liu
JZJingwei Zhao
Jingwei Zhao
DWDan Wang
Dan Wang
FPFan Peng
Fan Peng
ZYZhi Yang
Zhi Yang
Objective. Robot-assisted pedicle screw placement in spinal surgery can reduce the complications associated with the screw placement and reduce the hospital return counts due to malfunctions. However, it requires accurate planning for a high-quality procedure. The state-of-the-art technologies reported in the literature either ignore the anatomical variations across vertebrae or require substantial human interactions. We present an improved approach that achieves pedicle screw path planning through multiple projections of a numerically re-oriented vertebra with the estimated posture. Approach. We proposed an improved YOLO-type neural network model (YOLOPOSE3D) to estimate the posture of a vertebra before pedicle path planning. In YOLOPOSE3D, the vertebral posture is given as a rotation quaternion and 3D location coordinates by optimizing the intersection over union of the vertebra with the predicted posture and the actual posture. Then, a new local coordinate system is established for the vertebra based on the estimated posture. Finally, the optimal pedicle screw path trajectory is determined from the multiple projections of the vertebra in the local coordinates. Main results. The experimental results in difficult cases of scoliosis showed that the new YOLOPOSE3D network could accurately detect the location and posture of the vertebra with average translation and orientation errors as small as 1.55 mm and 2.55°. The screw path planning achieved 83.1% success rate without breaking the pedicle cortex for the lumbar vertebral L1–L5, which is better than that of a doctor’s manual planning, 82.4%. With the clinical class A requirement to allow less than 2 mm out of the pedicle cortex, the success rate achieved nearly 100%. Significance. The proposed YOLOPOSED3D method can accurately determine the vertebral postures. With the improved posture prior, better clinical outcomes can be achieved for pedicle screw placement in spine internal fixation procedures.

13 April 2024 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
JWJiayuan Wu
Jiayuan Wu
MFMingxing Fan
Mingxing Fan
DHDa He
Da He
YWYi Wei
Yi Wei
FDFangfang Duan
Fangfang Duan
WTWei Tian
Wei Tian