Liu Zhixiong

Liu Zhixiong

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2015 in IEEE Electrical Insulation Magazine
Verified
Journal Article
Closed access
LZLiu Zhixiong
Liu Zhixiong
BSBin Song
Bin Song
ELEn-Wen Li
En-Wen Li
YMYuan Mao
Yuan Mao
GWGuo-Li Wang
Guo-Li Wang
Most power transformers in the electrical power industry are oil filled, and insulation failure occurs when the oil-paper insulation system weakens to the extent that it can no longer support the high voltage connected to it. Dissolved gas analysis is a widely used method to detect incipient faults in oil-filled power transformers.

26 February 2022 in Energy Reports
Verified
Journal Article
Open access
CWChen Wang
Chen Wang
HPHuikun Pei
Huikun Pei
GTGuanghui Tang
Guanghui Tang
BLBingcai Liu
Bingcai Liu
LZLiu Zhixiong
Liu Zhixiong


1 December 2015 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
LZLiu Zhixiong
Liu Zhixiong
BSBin Song
Bin Song
YSYuanzhang Sun
Yuanzhang Sun
YYYun Yang
Yun Yang

21 January 2019 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
LZLiu Zhixiong
Liu Zhixiong
XFXiao-Bo Feng
Xiao-Bo Feng
Transmission power towers play an important role in power delivery systems. In recent years, some important results on reliability of transmission towers have been obtained based on theoretical analysis, but there are very few practical application systems of real‐time condition monitoring. This paper proposes a new real‐time reliable condition assessment system for 500kV transmission power towers based on stress measurement. The necessity of such systems and the architecture of the online monitoring system will first be presented. Through calculating the stress distribution condition of different components of the transmission tower under typical working conditions, those positions with relatively high failure probability in the transmission tower can be identified monitored for installing the stress sensors on them. A new method is presented for calculating the reliability index of the transmission tower structure is also developed based on the mechanical structure of the tower. In particular, the tower structure is simplified to a series system, and the Ditlevsen’s bounds is used to estimate the reliability of the tower system. Finally, a designed example for the online reliable condition assessment procedure is given using a 500kV oxytropis tower as an illustration.

21 April 2020 in IEEE Access
Verified
Journal Article
Open access
BXBin Xiang
Bin Xiang
LZLiu Zhixiong
Liu Zhixiong
KZKunyi Zhang
Kunyi Zhang
Distribution transformer is the key equipment in the distribution power grid, and sampling inspection is the main method used to ensure quality control. Inspection comprises many testing processes. Due to various reasons, the testing results may occasionally have errors and be implausible. Only a few errors can be detected empirically by inspectors. To solve this problem, anomaly detection is proposed in this paper to determine implausible inspection reports and assist in re-inspecting. The well-known and representative anomaly detection algorithms, which are now used in many application domains are introduced. These algorithms include single Gaussian distribution and multivariate Gaussian distribution, local outlier factor, one-class SVM. Based on the distribution transformer inspection reports collected, anomaly samples are constructed manually. Train datasets and test datasets are then formulated. By comparing the testing results, the one-class SVM algorithm can detect anomaly samples in testing datasets correctly. Thus, it can be used to distinguish the abnormal samples (i.e., reports with measurement errors suspected) in the inspection reports of distribution transformer, which can help inspectors complete their inspecting work correctly and effectively.