Algal ponds (APs) are widely used as treatment facilities for domestic sewage in sparsely populated rural areas. However, few AP studies have focused on daylight length to enhance pollutants removal. In this study, four algae ponds were set up, daylight was prolonged by 0, 2, 4, and 6 h with an illuminating intensity of 3000 lx. The highest removal efficiencies of total nitrogen, ammonium, and total phosphorus were 37.36%, 41.20%, and 21.56% due to the highest microbial abundance under optimum conditions (2 h PD), respectively. Excessive PD (4 h and 6 h) could inhibit the removal abilities. PD also increased the maximum relative electron transport rate of algae, leading to an increase in the photosynthetic capacity of APs. Meanwhile, the high microbial abundance indicates that chemoheterotrophic bacteria are the main influencing factor for the removal of nitrogen and phosphorus by the APs. Moreover, the system with PD using artificial lamps was proven to be feasible for engineering applications and potentially utilized in rural domestic wastewater treatment.
Constructed wetland systems employing submerged macrophytes are increasingly utilized for treating municipal and industrial wastewater, as well as odoriferous and eutrophic water bodies. However, the pollutant removal efficiency of these systems needs further enhancement. In this study, we examined the impact of the gas-to-water ratio on the treatment efficiency of the constructed wetland of Vallisneria. We also examined the extracellular polymeric substances (EPSs) of the floating biofilm and the structure of the microbial community in this system. Our findings showed that the gas-to-water ratio significantly affects the total nitrogen (TN) removal rate within the Vallisneria wetlands, with an optimum removal at a gas-to-water ratio of 15:1, while the removal efficiencies for chemical oxygen demand (COD), NH4+-N, and total phosphorus (TP) remain relatively unaffected. Increased gas-to-water ratios corresponded to a notable decrease in biofilm EPSs. High-throughput sequencing analysis demonstrated a shift in biofilm-denitrifying bacteria from anoxic heterotrophic to aerobic denitrifiers, alongside a significant rise in the abundance of denitrifying bacteria, whereas excessively high gas-to-water ratios inhibited the growth of these bacteria. A gas-to-water ratio of 15:1 constituted the optimal condition for ecological restoration of the water body within the Vallisneria wetland systems. These results could contribute to the optimization of submerged-macrophyte constructed wetland system design and the enhancement of treatment efficiency.
Submerged macrophytes play a crucial role in stabilizing urban aquatic ecosystems and are widely used in ecological restoration. However, their interactions with microbial communities in nitrogen removal under sewage stress remain unclear. In this study, we combined plant gene expression analysis, metabolite profiling, and microbial community sequencing to investigate Vallisneria natans and its associated microbiome under chronic nitrogen exposure (8 mg·L⁻¹). The stressed plants released chemical signals that recruited beneficial bacteria to inner microzones on their leaf surfaces, forming a mutualistic relationship in which bacteria enhance plant survival while consuming plant-produced carbon. This plant–microbiome system removed 35.3% of nitrogen at 16.17 ± 5.44°C, approximately 1.6 times higher than that of an artificial plant system. A combined process-based and data-driven model showed that this interaction contributed to over 50% of total nitrogen removal, highlighting submerged macrophytes as an effective nature-based strategy for restoring polluted urban aquatic ecosystems.