Bharati Ajay Mahajan

Mrs. Bharati Ajay Mahajan


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in AIDS Research and Therapy
Verified
Journal Article
Open access
PDF file
MTMadhuri Thakar
Madhuri Thakar
BMBharati Ajay Mahajan
Bharati Ajay Mahajan
NSNawaj Shaikh
Nawaj Shaikh
SBSalman Bagwan
Salman Bagwan
SSSuvarna Sane
Suvarna Sane
RPRamesh Paranjape
Ramesh Paranjape
In resource limited settings non-availability of CD4 count facility at the site could adversely affect the ART roll out programme. Point of care CD4 enumerating equipments can make the CD4 count available at the site of care and improve the patients’ management considerably. This study is aimed at determining the utility of a Point of Care PIMA CD4 analyzer (Alere, Germany) in the field settings in India.

1 January 2006 in AIDS Research and Therapy
Verified
Journal Article
Open access
MTMadhuri Thakar
Madhuri Thakar
BKB Kishore Kumar
B Kishore Kumar
BMBharati Ajay Mahajan
Bharati Ajay Mahajan
SMSanjay M Mehendale
Sanjay M Mehendale
RPRamesh S Paranjape
Ramesh S Paranjape
The CD4+ T cell count estimation is an important monitoring tool for HIV disease progression and efficacy of anti-retroviral treatment (ART). Due to availability of ART at low cost in developing countries, quest for reliable cost effective alternative methods for CD4+ T cell count estimation has gained importance. A simple capillary-based microflurometric assay (EasyCD4 System, Guava Technology) was compared with the conventional flow cytometric assay for estimation of CD4+ T cell counts in 79 HIV infected individuals. CD4+ T cell count estimation by both the assays showed strong correlation (r = 0.938, p < 0.001, 95% CI 0.90 to 0.96). The Bland Altman plot analysis showed that the limits of variation were within agreeable limits of ± 2SD (-161 to 129 cells/mm3). The Easy CD4 assay showed 100% sensitivity for estimating the CD4+ T cell counts < 200 cells/mm3 and < 350 cells/mm3 and 97% sensitivity to estimate CD4+ T cell count < 500 cells/mm3. The specificity ranged from 82 to 100%. The Kappa factor ranged from 0.735 for the CD4+ T cell counts < 350 cells/mm3 to 0.771 for < 500 cells/mm3 CD4+ T cell counts. The system works with a simple protocol, is easy to maintain and has low running cost. The system is compact and generates minimum amount of waste. Hence the EasyCD4 System could be applied for estimation of CD4+ T cell counts in resource poor settings.

14 August 2015 in AIDS Research and Therapy
Verified
Journal Article
Open access
PDF file
ASAshwini Shete
Ashwini Shete
DSDharmesh P Singh
Dharmesh P Singh
BMBharati Ajay Mahajan
Bharati Ajay Mahajan
AKAmol Kokare
Amol Kokare
RPRamesh Paranjape
Ramesh Paranjape
MTMadhuri Thakar
Madhuri Thakar
India has a large number of HIV infected patients being followed up at anti-retroviral therapy (ART) centers. The patients are regularly offered CD4 count estimation for deciding their eligibility for ART initiation as well as for monitoring response to ART, making CD4 count estimation a very critical test. Hence, quality control of CD4 testing is utmost important for ultimate success of ART program. As the commercial controls are very expensive, internal quality control (IQC), at present, is being done by duplicate analysis method using previous day samples in most of the laboratories. Hence the study was undertaken to review performance of duplicate analysis method for monitoring daily IQC. Quality control (QC) data from 11 Indian laboratories using duplicate analysis and/or commercial controls for IQC of CD4 testing was collected for reviewing information on QC parameters such as precision, accuracy and trend monitoring. Precision was determined by r2 values and mean % variation for duplicate analysis and coefficient of variation (% CV) for commercial controls. Accuracy was monitored by rate of QC failures for both the types of control and trend monitoring was done by plotting LJ charts for commercial controls and by plotting daily % variation for duplicate analysis. The laboratories using duplicate analysis for IQC showed good precision with mean % variation ranging from 0.5 to 7.2. There was good match between r2 values and % CV of the laboratories performing both the types of QC methods. Rates of QC failures were 2.3 for duplicate analysis and 3 per laboratory-year for IMMUNO-TROL controls. Daily trend monitoring showed fluctuation of daily counts around mean in LJ charts and of percent variation around 0% in duplicate analysis method. Commercially available controls showed limitations such as altered specimen quality leading to difficulties in manual gating and issues with the establishment of laboratory range. Duplicate analysis can serve as a cheaper alternative to commercially available controls for IQC of CD4 testing especially when supplemented with other QC measures for controlling variations caused by reagent, equipment, staff and environment in addition to the successful participation in External Quality Assurance programme.