Leonard S Fifield

Dr. Leonard S Fifield

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YSYongsoon Shin
Yongsoon Shin
MTMohammad Fuad Nur Taufique
Mohammad Fuad Nur Taufique
RDRam Devanathan
Ram Devanathan
ECErika C. Cutsforth
Erika C. Cutsforth
JLJaewon Lee
Jaewon Lee
DGDavid Gotthold
David Gotthold
A polyethersulfone (PES)-supported graphene oxide (GO) membrane has been developed by a simple casting approach. This stable membrane is applied for ethanol/water separation at different temperatures. The 5.0 µm thick GO film coated on PES support membrane showed a long-term stability over a testing period of one month and excellent water/ethanol selectivity at elevated temperatures. The water/ethanol selectivity is dependent on ethanol weight percentage in water/ethanol feed mixtures and on operating temperature. The water/ethanol selectivity was enhanced with an increase of ethanol weight percentage in water/ethanol mixtures, from below 100 at RT to close to 874 at a 90 °C for 90% ethanol/10% water mixture. Molecular dynamics simulation of water-ethanol mixtures in graphene bilayers, that are considered to play a key role in transport, revealed that molecular transport is negligible for layer spacing below 1 nm. The differences in the diffusion of ethanol and water in the bilayer are not consistent with the large selectivity value experimentally observed. The entry of water and ethanol into the interlayer space may be the crucial step controlling the selectivity.

2 July 2024 in Materials
Verified
Journal Article
Open access
PDF file
VKVishal Kumar
Vishal Kumar
Wenbin KuangWenbin Kuang
Wenbin Kuang
LFLeonard S Fifield
Leonard S Fifield
In the polymeric material industry, thermosets and related composites have played a substantial role in the production of rubber and plastics. One important subset of these is thermoset composites with carbon reinforcement. The incorporation of carbon fillers and fibers gives polymeric materials improved electrical and mechanical properties, among other benefits. However, the covalently crosslinked network of thermosets presents significant challenges for recycling and reprocessing because of its intractable nature. The introduction of vitrimer materials opens a new avenue to produce biodegradable and recyclable thermosets. Carbon-reinforced vitrimer composites are pursued for high-performance, long-lasting materials with attractive physical properties, the ability to be recycled and processed, and other features that respond uniquely to stimuli. The development of carbon-reinforced vitrimer composites over the last few years is summarized in this article. First, an overview of vitrimers and the methods used to prepare carbon fiber-reinforced vitrimer composites is provided. Because of the vitrimer nature of such composites, reprocessing, healing, and recycling are viable ways to greatly extend their service life; these approaches are thoroughly explained and summarized. The conclusion is our prediction for developing carbon-based vitrimer composites.

30 November 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
Muthu ElenMuthu Elen
Muthu Elen
VKVishal Kumar
Vishal Kumar
LFLeonard S Fifield
Leonard S Fifield
Over the last few decades, several marine renewable energy (MRE) technologies, such as wave energy converters (WECs) and current energy converters (CECs), have been developed. As opposed to traditional materials such as metal alloys, the structure of these technologies is made up of polymer and polymer composite materials. Most structures have been made using thermoset polymer composites; however, since thermoset polymer composites are not recyclable and lack sustainability, and with recent innovations in recyclable resins, bio-based resins, and the development of additive manufacturing technologies, thermoplastic polymers are increasingly being used. Nevertheless, the methodologies for identifying end-of-life options and recovering these polymer composites, as well as the recycling and reuse processes for MRE structures, are not well-studied. Specifically, since these MRE structures are subjected to salinity, moisture, varying temperature, biofouling, and corrosion effects depending on their usage, the recyclability after seawater aging and degradation needs to be explored. Hence, this review provides an in-depth review of polymer composites used in marine applications, the hygrothermal aging studies conducted so far to understand the degradation of these materials, and the reuse and recycling methodologies for end-of-life MRE structures, with a particular emphasis on sustainability.

1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Open access
SGSamuel W. Glass
Samuel W. Glass
AJA. M. Jones
A. M. Jones
LFLeonard S Fifield
Leonard S Fifield
THT. S. Hartman
T. S. Hartman
Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. Although system tests verify cable function under normal loads, demonstration of some cable’s ability to perform under exceptional loads associated with design-basis events is essential to assuring plant integrity. The cable’s ability to perform safely over the initial 40-year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program that includes condition monitoring to justify cable performance under normal operation as well as accident conditions. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none are suitable for all cable configurations nor does any single test confirm all features of interest. One particularly promising test that is beginning to be used more and more by utilities is frequency domain reflectometry (FDR). FDR is a nondestructive electrical inspection technique used to detect and localize faults in power and communication system conductors along the length of a cable from a single connection point. FDR detects discontinuities in the electrical impedance that arise due to cable splices or similar changes along the path of the conductor pair. In addition, FDR has the potential to provide sensitivity to insulation degradation by detecting small changes in impedance between the cable conductors being examined. The technique is also sensitive to cable bends, the particular lay of the cable in tray, proximity to other cable, and other factors that bear consideration when interpreting the test results. This paper examines various influences on the FDR approach and compares results of three different instruments to assess accelerated aging damage among several NPP representative cables.

7 August 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
NINazmul Al Imran
Nazmul Al Imran
SGSamuel W. Glass
Samuel W. Glass
LFLeonard S Fifield
Leonard S Fifield
MAMohammod Ali
Mohammod Ali
Interdigital capacitor (IDC) sensors are attractive in-situ sensors that can be used to measure permittivity variations in materials. Such sensors could be powerful enablers for cable insulation aging detection. Since insulation aging is correlated with a change in its material permittivity an IDC can measure that change via its measured capacitance. A new thin, flexible fabric-based IDC sensor is introduced for application on conformal curved surfaces such as an electrical cable surface. A multielectrode IDC and its backplane were fabricated using conductive copper polyester taffeta fabrics that were adhesively bonded to nonconductive polyester fabric. The sensor because of its soft flexible structure eliminates the problem of sensor conductor damage which is common for printed circuit board (PCB) type sensors when conformed to the surface of a cable. It also significantly reduces the airgap between the electrodes and the surface that they must contact in order to measure the capacitance. Airgap reduction and consistency are important in order to accurately predict permittivity variations in cable insulation material due to aging. Both PCB-based sensors and the new fabric-based sensors were built and tested on unaged cables and cables that underwent accelerated aging. Results demonstrate the proposed advantages of the novel fabric-based IDC sensor.

1 December 2023 in npj Materials Degradation
Verified
Journal Article
Open access
PDF file
YNYelin Ni
Yelin Ni
TBTucker T. Bisel
Tucker T. Bisel
KHKamrul Hasan
Kamrul Hasan
DLDonghui Li
Donghui Li
WFWitold K. Fuchs
Witold K. Fuchs
LFLeonard S Fifield
Leonard S Fifield
Many polymer-based medical devices are sterilized by gamma irradiation. To reduce the use of cobalt-60 gamma-ray sources, transition from gamma ray to alternative irradiation technologies was proposed, namely electron beam (e-beam) and X-ray. A major impediment for such a transition is the knowledge gap in material compatibility with the different radiation sources. In this study, multi-layer films consisting of ethylene vinyl acetate (EVA) and ethylene vinyl alcohol (EVOH) components were irradiated to target doses of 30, 45, and 60 kGy by gamma-ray, e-beam, and X-ray sources. Effects of irradiation were evaluated on 12 material properties, and statistical comparisons between gamma irradiation and alternative technologies were conducted using the two one-sided t-test (or “equivalence test”) and classic t-test. Melting temperature and UV absorbance below 300 nm showed dose dependencies, while other investigated properties such as discoloration and mechanical durability did not change with dose up to 60 kGy. Based on these results, there is no material compatibility issue associated with the transition from gamma to e-beam or to X-ray as source of sterilization radiation of the studied multi-layer film.