Simone Putzolu

Simone Putzolu

National Research Council of Italy (CNR), IBE/Institute Of Bioeconomy, Florence, Tuscany, Italy

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Giovanni GualtieriGiovanni Gualtieri
Giovanni Gualtieri
LBLorenzo Brilli
Lorenzo Brilli
Federico CarotenutoFederico Carotenuto
Federico Carotenuto
ACALICE CAVALIERE
ALICE CAVALIERE
Tommaso GiordanoTommaso Giordano
Tommaso Giordano
Beniamino GioliBeniamino Gioli
Beniamino Gioli
Two low-cost (LC) monitoring networks, PurpleAir (instrumented by Plantower PMS5003 sensors) and AirQino (Novasense SDS011), were assessed in monitoring PM2.5 and PM10 daily concentrations in the Padana Plain (Northern Italy). A total of 19 LC stations for PM2.5 and 20 for PM10 concentrations were compared vs. regulatory-grade stations during a full “heating season” (15 October 2022–15 April 2023). Both LC sensor networks showed higher accuracy in fitting the magnitude of PM10 than PM2.5 reference observations, while lower accuracy was shown in terms of RMSE, MAE and R2. AirQino stations under-estimated both PM2.5 and PM10 reference concentrations (MB = −4.8 and −2.9 μg/m3, respectively), while PurpleAir stations over-estimated PM2.5 concentrations (MB = +5.4 μg/m3) and slightly under-estimated PM10 concentrations (MB = −0.4 μg/m3). PurpleAir stations were finer than AirQino at capturing the time variation of both PM2.5 and PM10 daily concentrations (R2 = 0.68–0.75 vs. 0.59–0.61). LC sensors from both monitoring networks failed to capture the magnitude and dynamics of the PM2.5/PM10 ratio, confirming their well-known issues in correctly discriminating the size of individual particles. These findings suggest the need for further efforts in the implementation of mass conversion algorithms within LC units to improve the tuning of PM2.5 vs. PM10 outputs.

10 June 2026 in Atmosphere
Verified
Journal Article
Open access
PDF file
Simone PutzoluSimone Putzolu
Simone Putzolu
RITA BARALDIRITA BARALDI
RITA BARALDI
LNLuisa Neri
Luisa Neri
Alessandro ZaldeiAlessandro Zaldei
Alessandro Zaldei
CVCarolina Vagnoli
Carolina Vagnoli
CBCinzia De Benedictis
Cinzia De Benedictis
Students and workers spend much of their day in school and office environments, where poor indoor air quality (IAQ) can negatively affect health and comfort. Indoor vegetation is increasingly proposed as a low-cost nature-based solution (NBS) to improve IAQ. This study evaluated the effects of phytoremediation on IAQ and indoor microclimate in schools across different regions and educational levels, as well as in office environments, under real-world conditions. Several C3 plants (e.g., Chamaedorea, Schefflera, Ficus, Epipremnum, Yucca, and Spathiphyllum) were used, with crassulacean acid metabolism (CAM) plants (Sansevieria) included in selected settings. Temperature, relative humidity, CO2, PM2.5, and PM10 were continuously monitored using intercalibrated low-cost sensors in absence and presence of vegetation. A comparable plant configuration was implemented in offices to assess its effects on volatile organic compounds (VOC). Indoor greenery reduced particulate matter, especially PM10 (18–20%), and improved microclimatic conditions by lowering air temperature (1–2 °C) and increasing relative humidity (6–15%). However, CO2 reductions were limited and context-dependent. In the tested office environments, plant introduction was associated with reduced total VOC concentrations (25–50%). Overall, our results further support that indoor vegetation constitutes a robust, cost-effective nature-based solution (NBS) capable of complementing conventional ventilation systems in both school and office environments.

30 April 2026 in Journal of Theoretical and Applied Vascular Research
Verified
Journal Article
Open access
PDF file
Simone PutzoluSimone Putzolu
Simone Putzolu
ACAnna Maria Ciciani
Anna Maria Ciciani
TGTommaso Giorgetti
Tommaso Giorgetti
SLSofia Lombari
Sofia Lombari
EPEros Pire
Eros Pire
Beniamino GioliBeniamino Gioli
Beniamino Gioli
The “Plants in the Classroom” project, conducted at the Gobetti-Volta Scientific High School in Bagno a Ripoli (Italy), originated from the need to scientifically investigate indoor air quality in school classrooms. With the support of the International Society of Doctors for the Environment (ISDE-Sezione Firenze), the scientific coordination of the National Research Council – Institute of BioEconomy (CNR-IBE) in Florence, and the active involvement of students and teachers, three classes were equipped with plant species selected for their air-purifying properties. Indoor environmental parameters (CO2, PM2.5, relative humidity, and temperature) were continuously monitored using low-cost AirQino stations, previously applied and validated in other environmental contexts, enabling cost-effective measurements in real school settings. Measurements were compared with those collected in a fourth classroom without plants, which served as a control. While acknowledging limitations such as the limited number of plants, structural differences between classrooms, and variable ventilation conditions, the collected data offer a reliable snapshot of everyday classroom management. The results show how plants, through photosynthesis and transpiration, contributed to reducing CO2 and PM2.5 levels and increasing relative humidity. In addition to the environmental benefits, students reported improvements in concentration and perceived well-being. Overall, the project represents a replicable model of active learning and ecological awareness.