The aim of this study is to investigate the effects of implant orientation and implant material on tibia bone strain, implant–bone micromotion, maximum contact pressure, and wear depth at the articulating surface due to total ankle replacement. Three-dimensional finite element models of intact and implanted ankle were developed from computed tomography scan data. Four implanted models were developed having varus and valgus orientations of 5° and 10°, respectively. In order to determine the effect of implant material combination on tibia bone strain, micromotion, contact pressure, and wear depth, three other finite element models were developed having a different material combination of the implant. Dorsiflexion, neutral, and plantarflexion positions were considered as applied loading condition, along with muscle force and ligaments. Implant orientation alters the strain distribution in tibia bone. Strain shielding was found to be less in the case of the optimally positioned implant. Apart from the strain, implant orientation also affects implant–bone micromotion, contact pressure, and wear depth. Implant materials have less influence on tibia bone strain and micromotion. However, wear depth was reduced when ceramic and carbon fibre–reinforced polyetheretherketone material combination was used. Proper orientation of the implant is important to reduce the strain shielding. The present result suggested that ceramic can be used as an alternative to metal and carbon fibre–reinforced polyetheretherketone as an alternative to ultra-high molecular weight polyethylene to reduce wear, which would be beneficial for long-term success and fixation of the implant.
The long-term success of total ankle replacement (TAR) depends on both bone ingrowth and remodelling. The extreme values of implant-bone micromotion hinder bone ingrowth. Whereas, bone resorption due to bone remodelling is triggered by stress shielding. This study aims to investigate the biomechanical performance of three popular tibial designs (STAR, Salto and Mobility) for TAR with different implant-bone interfacial conditions and bone qualities. In this study, CT data were used for the geometric modelling of bone. The cancellous bone was considered to be heterogeneous with location-based properties. Total 48 Finite Element (FE) models were prepared i.e., 45 implanted and 3 intact. For the three designs, three bone qualities were considered. For each bone quality, five implant-bone interface coefficients of friction were considered (0.1 to 0.5). The proximal part of the tibia was fully constrained and dorsiflexion loading condition was applied. There was a reduction in micromotion as the coefficient of friction increased and increase in micromotion as the bone quality reduced. The effect of implant-bone coefficient of friction was trivial on tibial stress (von Mises stress) however, bone quality and implant design was considerable. Stress shielding was seen in all the models and it increased when the bone quality degraded. This study establishes the effect of the implant-bone interfacial condition, bone quality and implant design on implant-bone micromotion and bone stress. For long-term fixation of the tibial component, due attention should be given while selecting the tibial component design for TAR, especially for STAR and Mobility design.
One of the major causes of implant loosening is due to excessive bone resorption surrounding the implant due to bone remodelling. The objective of the study is to investigate the effects of implant material and implant–bone interface conditions on bone remodelling around tibia bone due to total ankle replacement. Finite element models of intact and implanted ankles were developed using CT scan data sets. Bone remodelling algorithm was used in combination with FE analysis to predict the bone density changes around the ankle joint. Dorsiflexion, neutral, and plantar flexion positions were considered, along with muscle force and ligaments. Implant–bone interfacial conditions were assumed as debonded and bonded to represent non-osseointegration and fully osseointegration at the porous coated surface of the implant. To investigate the effect of implant material, three finite element models having different material combinations of the implant were developed. For model 1, tibial and talar components were made of Co–Cr–Mo, and meniscal bearing was made of UHMWPE. For model 2, tibial and talar components were made of ceramic and meniscal bearing was made of UHMWPE. For model 3, tibial and talar components were made of ceramic and meniscal bearing was made of CFR-PEEK. Changes in implant material showed no significant changes in bone density due to bone remodelling. Therefore, ceramic appears to be a viable alternative to metal and CFR-PEEK can be used in place of UHMWPE. This study also indicates that proper bonding between implant and bone is essential for long-term survival of the prosthetic components.
24 August 2024 in International Journal of Mechanical Sciences