Taiga Itagaki

Prof. Dr. Taiga Itagaki

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2007 in British Journal of Anaesthesia
Verified
Journal Article
Closed access
MKM. Kikura
M. Kikura
KSK. Suzuki
K. Suzuki
TITaiga Itagaki
Taiga Itagaki
TTT. Takada
T. Takada
SSS. Sato
S. Sato
Vocal cord paralysis after tracheal intubation may be attributed to ageing and comorbidity. However, the relationship between patient characteristics and the risk of vocal cord paralysis is unknown. We prospectively analysed data representing 31 241 consecutive surgery patients who underwent tracheal intubation to determine whether duration of intubation, age, sex, and cardiovascular, cerebrovascular, and metabolic diseases were risk factors for vocal cord paralysis associated with intubation. Patients with vocal cord paralysis from any other causes were excluded. Twenty-four (0.077%) suffered vocal cord paralysis (left, 16 patients; right, 8 patients). The risk was increased when intubation lasted 3-6 h (odds ratio, 2.0; 95% confidence interval, 1.1-5.6; P = 0.002) or 6 h or more (odds ratio, 14.5; 95% confidence interval, 5.2-40.9; P < 0.0001). The risk was increased in patients aged 50-69 (odds ratio, 3.6; 95% confidence interval, 1.2-11.1; P = 0.02) and 70 yr or above (odds ratio, 3.9; 95% confidence interval, 1.2-12.8; P = 0.02). The risk was increased with diabetes mellitus (odds ratio, 2.5; 95% confidence interval, 1.1-7.3; P = 0.03) and hypertension (odds ratio, 2.1; 95% confidence interval, 1.1-6.0; P = 0.03). The risk of vocal cord paralysis was increased three-fold in patients aged 50 or above, two-fold in patients intubated 3-6 h, 15-fold in patients intubated 6 h or more, and two-fold in patients with a history of diabetes mellitus or hypertension. Our results are informative for informed consent, patient counselling, and intubation decision-making.

16 December 2019 in Journal of Intensive Care
Verified
Journal Article
Open access
PDF file
Nobuto NakanishiNobuto Nakanishi
Nobuto Nakanishi
RTRie Tsutsumi
Rie Tsutsumi
YOYoshihiro Okayama
Yoshihiro Okayama
TTTakuya Takashima
Takuya Takashima
YUYoshitoyo Ueno
Yoshitoyo Ueno
JOJun Oto
Jun Oto
Background: Skeletal muscle atrophy commonly occurs in critically ill patients, and decreased muscle mass is associated with worse clinical outcomes. Muscle mass can be assessed using various tools, including ultrasound and bioelectrical impedance analysis (BIA). However, the effectiveness of muscle mass monitoring is unclear in critically ill patients. This study was conducted to compare ultrasound and BIA for the monitoring of muscle mass in critically ill patients. Methods: We recruited adult patients who were expected to undergo mechanical ventilation for > 48 h and to remain in the intensive care unit (ICU) for > 5 days. On days 1, 3, 5, 7, and 10, muscle mass was evaluated using an ultrasound and two BIA devices (Bioscan: Malton International, England; Physion: Nippon Shooter, Japan). The influence of fluid balance was also evaluated between each measurement day. Results: We analyzed 93 images in 21 patients. The age of the patients was 69 (interquartile range, IQR, 59–74) years, with 16 men and 5 women. The length of ICU stay was 11 days (IQR, 9–25 days). The muscle mass, monitored by ultrasound, decreased progressively by 9.2% (95% confidence interval (CI), 5.9–12.5%), 12.7% (95% CI, 9.3–16.1%), 18.2% (95% CI, 14.7–21.6%), and 21.8% (95% CI, 17.9–25.7%) on days 3, 5, 7, and 10 (p < 0.01), respectively, with no influence of fluid balance (r = 0.04, p = 0.74). The muscle mass did not decrease significantly in both the BIA devices (Bioscan, p = 0.14; Physion, p = 0.60), and an influence of fluid balance was observed (Bioscan, r = 0.37, p < 0.01; Physion, r = 0.51, p < 0.01). The muscle mass assessment at one point between ultrasound and BIA was moderately correlated (Bioscan, r = 0.51, p < 0.01; Physion, r = 0.37, p < 0.01), but the change of muscle mass in the same patient did not correlate between these two devices (Bioscan, r = − 0.05, p = 0.69; Physion, r = 0.23, p = 0.07). Conclusions: Ultrasound is suitable for sequential monitoring of muscle atrophy in critically ill patients. Monitoring by BIA should be carefully interpreted owing to the influence of fluid change. Trial registration: UMIN000031316. Retrospectively registered on 15 February 2018.

1 January 2014 in Respiratory Care
Verified
Journal Article
Open access
PDF file
TITaiga Itagaki
Taiga Itagaki
NONao Okuda
Nao Okuda
YTYumiko Tsunano
Yumiko Tsunano
HKHisakazu Kohata
Hisakazu Kohata
ENEmiko Nakataki
Emiko Nakataki
MNMasaji Nishimura
Masaji Nishimura
BACKGROUND: High-flow nasal cannula (HFNC) creates positive oropharyngeal airway pressure and improves oxygenation. It remains unclear, however, whether HFNC improves thoraco-abdominal synchrony in patients with mild to moderate respiratory failure. Using respiratory inductive plethysmography, we investigated the effects of HFNC on thoraco-abdominal synchrony. METHODS: We studied 40 adult subjects requiring oxygen therapy in the ICU. Low-flow oxygen (up to 8 L/min) was administered via oronasal mask for 30 min, followed by HFNC at 30–50 L/min. Respiratory inductive plethysmography transducer bands were circumferentially placed: one around the rib cage, and one around the abdomen. We measured the movement of the rib-cage and abdomen, and used the sum signal to represent tidal volume (VT) during mask breathing, and at 30 min during HFNC. We calculated the ratio of maximum compartmental amplitude (MCA) to VT, and the phase angle. We assessed arterial blood gas and vital signs at each period, and mouth status during HFNC. We used multiple regression analysis to identify factors associated with improvement in thoraco-abdominal synchrony. RESULTS: During HFNC, breathing frequency significantly decreased from 25 breaths/min (IQR 22–27 breaths/min) to 21 breaths/min (IQR 18–24 breaths/min) (P < .001), and MCA/VT (P < .001) and phase angle (P = .047) significantly improved. CONCLUSIONS: HFNC improved thoraco-abdominal synchrony in adult subjects with mild to moderate respiratory failure.

26 December 2013 in Respiratory Care
Verified
Journal Article
Closed access
YCYusuke Chikata
Yusuke Chikata
MIMasayo Izawa
Masayo Izawa
NONao Okuda
Nao Okuda
TITaiga Itagaki
Taiga Itagaki
ENEmiko Nakataki
Emiko Nakataki
MNMasaji Nishimura
Masaji Nishimura
INTRODUCTION: Delivering heated and humidified medical gas at 20–60 L/min, high-flow nasal cannula (HFNC) creates low levels of PEEP and ameliorates respiratory mechanics. It has become a common therapy for patients with respiratory failure. However, independent measurement of heat and humidity during HFNC and comparison of HFNC devices are lacking. METHODS: We evaluated 2 HFNC (Airvo 2 and Optiflow system) devices. Each HFNC was connected to simulated external nares using the manufacturer's standard circuit. The Airvo 2 outlet-chamber temperature was set at 37°C. The Optiflow system incorporated an O 2 /air blender and a heated humidifier, which was set at 40°C/−3. For both systems, HFNC flow was tested at 20, 40, and 50 L/min. Simulating spontaneous breathing using a mechanical ventilator and TTL test lung, we tested tidal volumes (V T ) of 300, 500, and 700 mL, and breathing frequencies of 10 and 20 breaths/min. The TTL was connected to the simulated external nares with a standard ventilator circuit. To prevent condensation, the circuit was placed in an incubator maintained at 37°C. Small, medium, and large nasal prongs were tested. Absolute humidity (AH) of inspired gas was measured at the simulated external nares. RESULTS: At 20, 40, and 50 L/min of flow, respective AH values for the Airvo 2 were 35.3 ± 2.0, 37.1 ± 2.2, and 37.6 ± 2.1 mg/L, and for the Optiflow system, 33.1 ± 1.5, 35.9 ± 1.7, and 36.2 ± 1.8 mg/L. AH was lower at 20 L/min of HFNC flow than at 40 and 50 L/min ( P < .01). While AH remained constant at 40 and 50 L/min, at 20 L/min of HFNC flow, AH decreased as V T increased for both devices. CONCLUSIONS: During bench use of HFNC, AH increased with increasing HFNC flow. When the inspiratory flow of spontaneous breathing exceeded the HFNC flow, AH was influenced by V T . At all experimental settings, AH remained > 30 mg/L.

2 December 2019 in Journal of Intensive Care
Verified
Journal Article
Open access
PDF file
Nobuto NakanishiNobuto Nakanishi
Nobuto Nakanishi
JOJun Oto
Jun Oto
YUYoshitoyo Ueno
Yoshitoyo Ueno
ENEmiko Nakataki
Emiko Nakataki
TITaiga Itagaki
Taiga Itagaki
MNMasaji Nishimura
Masaji Nishimura
Background: Diaphragm atrophy is observed in mechanically ventilated patients. However, the atrophy is not investigated in other respiratory muscles. Therefore, we conducted a two-center prospective observational study to evaluate changes in diaphragm and intercostal muscle thickness in mechanically ventilated patients. Methods: Consecutive adult patients who were expected to be mechanically ventilated longer than 48 h in the ICU were enrolled. Diaphragm and intercostal muscle thickness were measured on days 1, 3, 5, and 7 with ultrasonography. The primary outcome was the direction of change in muscle thickness, and the secondary outcomes were the relationship of changes in muscle thickness with patient characteristics. Results: Eighty patients (54 males and 26 females; mean age, 68 ± 14 years) were enrolled. Diaphragm muscle thickness decreased, increased, and remained unchanged in 50 (63%), 15 (19%), and 15 (19%) patients, respectively. Intercostal muscle thickness decreased, increased, and remained unchanged in 48 (60%), 15 (19%), and 17 (21%) patients, respectively. Decreased diaphragm or intercostal muscle thickness was associated with prolonged mechanical ventilation (median difference (MD), 3 days; 95% CI (confidence interval), 1–7 and MD, 3 days; 95% CI, 1–7, respectively) and length of ICU stay (MD, 3 days; 95% CI, 1–7 and MD, 3 days; 95% CI, 1–7, respectively) compared with the unchanged group. After adjusting for sex, age, and APACHE II score, they were still associated with prolonged mechanical ventilation (hazard ratio (HR), 4.19; 95% CI, 2.14–7.93 and HR, 2.87; 95% CI, 1.53–5.21, respectively) and length of ICU stay (HR, 3.44; 95% CI, 1.77–6.45 and HR, 2.58; 95% CI, 1.39–4.63, respectively) compared with the unchanged group. Conclusions: Decreased diaphragm and intercostal muscle thickness were frequently seen in patients under mechanical ventilation. They were associated with prolonged mechanical ventilation and length of ICU stay. Trial registration: UMIN000031316. Registered on 15 February 2018

1 June 2007 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
TITaiga Itagaki
Taiga Itagaki
MKMutsuhito Kikura
Mutsuhito Kikura
SSShigehito Sato
Shigehito Sato