Kien Nguyen Phan

Dr. Kien Nguyen Phan

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2023
Verified
Book Chapter
Closed access
PDF file
KPKien Nguyen Phan
Kien Nguyen Phan
ANAnh Thuy Nguyen
Anh Thuy Nguyen
TDThanh Binh Doan
Thanh Binh Doan
PTPhu Nguyen Trung
Phu Nguyen Trung
NTNhung Dinh Thi
Nhung Dinh Thi

23 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
PTPhu Nguyen Trung
Phu Nguyen Trung
BNBa-Nghien Nguyen
Ba-Nghien Nguyen
KPKien Nguyen Phan
Kien Nguyen Phan
HVHa Pham Van
Ha Pham Van
TVThao Hoang Van
Thao Hoang Van
AGAmir Gandjbakhche
Amir Gandjbakhche
Height is an important health parameter employed across domains, including healthcare, aesthetics, and athletics. Numerous non-contact methods for height measurement exist; however, most are limited to assessing height in an upright posture. This study presents a non-contact approach for measuring human height in 2D space across different postures. The proposed method utilizes computer vision techniques, specifically the MediaPipe library and the YOLOv8 model, to analyze images captured with a smartphone camera. The MediaPipe library identifies and marks joint points on the human body, while the YOLOv8 model facilitates the localization of these points. To determine the actual height of an individual, a multivariate linear regression model was trained using the ratios of distances between the identified joint points. Data from 166 subjects across four distinct postures: standing upright, rotated 45 degrees, rotated 90 degrees, and kneeling were used to train and validate the model. Results indicate that the proposed method yields height measurements with a minimal error margin of approximately 1.2%. Future research will extend this approach to accommodate additional positions, such as lying down, cross-legged, and bent-legged. Furthermore, the method will be improved to account for various distances and angles of capture, thereby enhancing the flexibility and accuracy of height measurement in diverse contexts.

10 April 2020 in Advances in Intelligent Systems and Computing
Verified
Book Chapter
Closed access
PDF file
KPKien Nguyen Phan
Kien Nguyen Phan
VTVu Anh Tran
Vu Anh Tran
TDTrung Thanh Dang
Trung Thanh Dang

28 December 2023
Verified
Conference Paper
Closed access
TDToan Tran Duc
Toan Tran Duc
KPKien Nguyen Phan
Kien Nguyen Phan
PLPhuong Nguyen Lan
Phuong Nguyen Lan
PMPhuong Bui Thi Mai
Phuong Bui Thi Mai
DNDat Chu Ngoc
Dat Chu Ngoc
PTPhu Nguyen Trung
Phu Nguyen Trung
Bedside weighing offers a helpful alternative to traditional weighing procedures for patients who are in resuscitation as well as for those who are unable to leave their beds. However, currently, the devices only measure the patient's weight characteristics then the doctors must use a formula to calculate therapy parameters. So, the research focuses on designing and manufacturing a bedside scale having embedded software to calculate treatment parameters for patients immediately after getting the weight of the patient. Design and manufacture of mechanical systems, electrical circuit systems, treatment parameter research and synthesis, formula construction, and integrated software programming are all included. A mobile bedside scale for weighing resuscitation patients has been done with a 150kg maximum weight range, ±0,1kg per step in the full range measurement errors, and software that can be used to calculate treatment parameters for patients like BMI, glomerular filtration rate, vasopressor dose, and infusion volume. The patient is also given advice on dietary requirements as well as antibiotic doses. The bedside scale with embedded software to calculate treatment parameters for resuscitated patients is unique in the world. It will shorten the time of decision-making for doctors during curing ICU patients. In the future, this bedside scale will apply at Ha Dong General Hospital and some other hospitals in Vietnam to assess its capability in ICU units.

30 August 2023 in Tạp chí Y học Việt Nam
Verified
Journal Article
Open access
PDF file
KPKien Nguyen Phan
Kien Nguyen Phan
BĐBình Tĩnh Đoàn
Bình Tĩnh Đoàn
HLHoàng Oanh Lê
Hoàng Oanh Lê
Mục tiêu: 1. Mục tiêu của nghiên cứu là hướng đến rút ngắn thời gian ra quyết định cho bệnh nhân hồi sức trong quá trình điều trị. 2. Tích hợp phần mềm cho thiết bị cân bệnh nhân hồi sức và ứng dụng tại Bệnh viện Đa Khoa Hà Đông. Phương pháp: Nghiên cứu tổng hợp các thông số, xây dựng các công thức và phần mềm hoá và tích hợp trên cân bệnh nhân hồi sức tại khoa hồi sức tích cực và chống độc, Bệnh viện Đa khoa Hà Đông. Kết quả: Một thiết bị cân bệnh nhân hồi sức di động đã được thiết kế thành công với dải cân nặng đạt tối đa 200kg, độ chính xác phép đo đạt ± 0,05kg/ toàn dải đo, đồng thời phần mềm hỗ trợ cho phép tính toán ngay các thông số bao gồm BMI, tính mức lọc cầu thận, tính các liều thuốc vận mạch, tính lượng dịch trong test truyền dịch đồng thời cung cấp các bảng thông tin về liều thuốc kháng sinh và nhu cầu dinh dưỡng cho bệnh nhân. Kết luận: Với phần mềm hỗ trợ tính toán các thông số điều trị cho bệnh nhân được tích hợp lên cân bệnh nhân hồi sức di động cho thấy thời gian tính toán các thông số của bác sĩ được rút ngắn đáng kể, chưa kể thiết bị cân bệnh nhân hồi sức với các thông tin đã cung cấp cho phép các bệnh viện có thêm 01 thiết bị vừa phục vụ điều trị cho bệnh nhân mà còn có thêm 01 thiết bị đào tạo chuyên ngành hồi sức cấp cứu một cách thuận tiện nhất.

26 August 2022 in Journal of Military Science and Technology
Verified
Journal Article
Closed access
TDThanh Trung Dang
Thanh Trung Dang
KPKien Nguyen Phan
Kien Nguyen Phan
CHChu Duc Hoang
Chu Duc Hoang
TNThanh Trung Nguyen
Thanh Trung Nguyen
Several investigations contributed to developing the Electrical Resistivity Spectroscopy equipment used to evaluate meat standards. In the prior research, a method for effectively calculating the power resistance spectra of pork meat was devised. This method was successfully implemented. Electrodes fabricated from medical knitting needles and the term means syringes were used in this study to measure the energy-dispersive spectra of flesh. These two different transducers were constructed for the investigation and employed in the measurement process. In medicine, both types of electrodes are utilized; however, assessment findings acquired using the same equipment reveal a distinct disparity between the outcomes of the two measurements. This demonstrates that selecting an electrode for a specific measurement requires careful consideration and consideration overall. In the coming years, the investigation and advancement of weighing electrodes, which are utilized to assess the electronic input resistance of pork meat and over which the research group is concentrating, are further investigated to develop the measurement system electrodes the most appropriate and essential. Using data from knowledge grows.