Qiao Lin

Ms. Qiao Lin


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Xin DingXin Ding
Xin Ding
QLQiao Lin
Qiao Lin
MWMengjie Wang
Mengjie Wang
SLShen Liu
Shen Liu
WZWei Guan Zhang
Wei Guan Zhang
Yiping WangYiping Wang
Yiping Wang
A novel surface plasmon resonance (SPR) refractive index (RI) sensor based on the D-type dual-mode photonic crystal fiber (PCF) is proposed. The sensor employs a side-polished few-mode PCF that facilitates the transmission of the fundamental and second-order modes, with an integrated microfluidic channel positioned directly above the fiber core. This design minimizes the distance to the analyte and maximizes the interaction between the optical field and the analyte, thereby enhancing the SPR effect and resonance loss for improved sensing performance. Au-TiO2 dual-layer material was coated on the surface of a microfluidic channel to enhance the penetration depth of the core evanescent field and tune the resonance wavelength to the near-infrared band, meeting the special needs of chemical and biomedical detection fields. The finite element method was utilized to systematically investigate the coupling characteristics between various modes and surface plasmon polariton (SPP) modes, as well as the impact of structural parameters on the sensor performance. The results indicate that the LP11b_y mode exhibits greater wavelength sensitivity than the HE11_y mode, with a maximum sensitivity of 33,000 nm/RIU and an average sensitivity of 8272.7 nm/RIU in the RI sensing range of 1.25–1.36, which is higher than the maximum sensitivity of 16,000 nm/RIU and average sensitivity of 5666.7 nm/RIU for the HE11b_y mode. It is believed that the proposed PCF-SPR sensor features both high sensitivity and high resolution, which will become a critical device for wide RI detection in mid-infrared fields.

23 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SLShen Liu
Shen Liu
HXHang Xiao
Hang Xiao
YCYanping Chen
Yanping Chen
PCPeijing Chen
Peijing Chen
WYWenqi Yan
Wenqi Yan
Junle QuJunle Qu
Junle Qu
Nanomechanical resonators made from suspended graphene combine the properties of ultracompactness and ultrahigh detection sensitivity, making them interesting devices for sensing applications. However, nanomechanical systems can be affected by membrane stress. The present work developed an optomechanical resonator for thermal stress sensing. The proposed resonator consists of a section of hollow core fiber (HCF) and a trampoline graphene–Au membrane. An all-optical system that integrated optical excitation and optical detection was applied. Then, the resonance frequency of the resonator was obtained through this all-optical system. In addition, this system and the resonator were used to detect the membrane’s built-in stress, which depended on the ambient temperature, by monitoring the resonance frequency shift. The results verified that the temperature-induced thermal effect had a significant impact on membrane stress. Temperature sensitivities of 2.2646 kHz/°C and 2.3212 kHz/°C were obtained when the temperature rose and fell, respectively. As such, we believe that this device will be beneficial for the quality monitoring of graphene mechanical resonators.

6 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Xin DingXin Ding
Xin Ding
QLQiao Lin
Qiao Lin
SLShen Liu
Shen Liu
ZLzhang lianzhen
zhang lianzhen
NCNan Chen
Nan Chen
Yiping WangYiping Wang
Yiping Wang
A highly sensitivity balloon-like fiber interferometer based on ethanol coating is presented in this paper. The Mach–Zehnder interferometer is formed by bending a single-mode fiber to a balloon-like structure and nested in the Teflon tube. Then, an ethanol solution was filled into the tube of the balloon-like fiber interferometer by the capillary effect. Due to the high sensitivity of the refractive index (RI) of ethanol solutions to temperature, when the external temperature varies, the optical path difference changes. The change in temperature can be detected by the shift in the interference spectrum. Limited by the size of the balloon-like structure, three kinds of these structures with different sensitive lengths were prepared to select the best parameters. The sensitive lengths were 10, 15 and 20 mm, respectively, and the RI detection performance of each structure in 10~26% NaCl solutions was investigated experimentally. The results show that when the sensitive length is 20 mm, the RI sensitivity of the sensor is the highest, which is 212.88 nm/RIU. Ultimately, the sensitive length filled with ethanol is 20 mm. The experimental results show that the temperature sensitivity of the structure is 1.145 nm/°C in the range of 28.1 °C~35 °C, which is 10.3 times higher than that of an unfilled balloon-like structure (0.111 nm/°C). The system has the advantages of low cost and easy fabrication, which can potentially be used in high-precision temperature monitoring processes.