Youhua Chen

Prof. Youhua Chen

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
NHNing He
Ning He
HHHuiqin Hu
Huiqin Hu
ZCZhiying Cui
Zhiying Cui
XXXinjun Xu
Xinjun Xu
DZDakai Zhou
Dakai Zhou
CKCuifang Kuang
Cuifang Kuang
Spectral confocal sensors are effective for measuring displacements. The core of the spectral confocal measurement system is a dispersive objective lens that uses optical dispersion to establish a one-to-one correspondence between the focusing position and wavelength, achieving high-resolution measurements in the longitudinal direction. Despite significant progress in dispersive objective lenses for spectral confocal sensor systems, challenges such as a limited dispersion range, high cost, and insufficient measurement accuracy persist. To expand the measurement range and improve the accuracy of the spectral confocal sensor, we designed a compact, long-axial dispersion objective lens. This lens has a simple structure that requires only six lens elements, two of which form cemented doublets. The system length is 58 mm, with a working distance of 46 ± 6 mm and a dispersion range of 12 mm within the wavelength range of 450–656 nm. The lens has an object-side numerical aperture (NA) of 0.22 and an image-side NA between 0.198 and 0.24, ensuring high light energy utilization. Finally, a spectral confocal measurement system was constructed based on the designed dispersive objective lens, and performance evaluation tests were conducted. The test results showed that the system achieved a resolution of 0.15 μm and a maximum linear error of ±0.7 μm, demonstrating high-precision measurement capabilities. The proposed lens design enables the development of more portable and cost-effective spectral confocal sensors.

3 July 2023 in Applied Optics
Verified
Journal Article
Closed access
QLQingqing Liu
Qingqing Liu
DZDakai Zhou
Dakai Zhou
JZJinfeng Zhang
Jinfeng Zhang
CJCheng Ji
Cheng Ji
KDKuangwei Du
Kuangwei Du
CKCuifang Kuang
Cuifang Kuang
In this study, we developed a novel, compact, and efficient structured illumination microscopy (SIM) system, to our best knowledge. A binary hexagonal lattice pattern was designed and implemented on a digital micromirror device (DMD), resulting in a projection-based structured-light generation. By leveraging the combination of the high-speed switching capability of the DMD with a high-speed CMOS camera, the system can capture 1024×1024 pixels images at a 200 fps frame rate when provided with sufficient illumination power. The loading of the hexagonal lattice pattern reduces the number of images required for reconstruction to seven, and by utilizing the DMD modulating characteristics on the illumination path, there is no need to use bulky mechanical structures for phase shifting. We designed a compact system with 110mm×150mm×170mm dimensions that displayed a 1.61 resolution enhancement for fluorescent particle and biological sample imaging.

5 April 2022 in Optics Express
Verified
Journal Article
Closed access
FXFanghui Xu
Fanghui Xu
JZJiachen Zhang
Jiachen Zhang
DDDongdong Ding
Dongdong Ding
WLWenjie Liu
Wenjie Liu
CZChi Zheng
Chi Zheng
CKCuifang Kuang
Cuifang Kuang
Structured illumination microscopy (SIM), a super-resolution technology, has a wide range of applications in life sciences. In this study, we present an electro-optic high-speed phase-shift super-resolution microscopy imaging system including 2D SIM, total internal reflection fluorescence-SIM, and 3D SIM modes. This system uses galvanometers and an electro-optic modulator to flexibly and quickly control the phase and direction of structured illumination patterns. Moreover, its design consists of precise timing for improved acquisition speed and software architecture for real-time reconstruction. The highest acquisition rate achieved was 151 frames/s, while the highest real-time super-resolution reconstruction frame rate achieved was over 25 frames/s.

16 May 2023 in Optics Letters
Verified
Journal Article
Closed access
KDKuangwei Du
Kuangwei Du
DZDakai Zhou
Dakai Zhou
SZSijia Zhou
Sijia Zhou
JZJinfeng Zhang
Jinfeng Zhang
QLQingqing Liu
Qingqing Liu
CKCuifang Kuang
Cuifang Kuang
We propose a quasi-confocal microscopy autofocus system incorporating an electrically tunable lens (ETL) to achieve differential detection. The ETL changes its focal length to collect differential curves at speeds <300 Hz, allowing selective locking onto desired focal layers and high-speed differential operations close to the locked focal plane. By segmenting the system’s pupil, the interference between the outgoing and incoming near-infrared beams is avoided, thereby greatly improving the signal-to-noise ratio. This ultra-sensitive system, with a focus drift accuracy better than 1/22 focal depth (∼20 nm @100× objective), provides a new, to the best of our knowledge, implementation pathway to meet the requirements of various microscopy techniques.

19 October 2024 in Photonics
Verified
Journal Article
Open access
PDF file
ZCZhiying Cui
Zhiying Cui
YXYi Xing
Yi Xing
YCYunbo Chen
Yunbo Chen
XZXiu Zheng
Xiu Zheng
WLWenjie Liu
Wenjie Liu
YCYouhua Chen
Youhua Chen
Confocal laser scanning microscopy is one of the most widely used tools for high-resolution imaging of biological cells. However, the imaging resolution of conventional confocal technology is limited by diffraction, and more complex optical principles and expensive optical-mechanical structures are usually required to improve the resolution. This study proposed a deep residual neural network algorithm that can effectively improve the imaging resolution of the confocal microscopy in real time. The reliability and real-time performance of the algorithm were verified through imaging experiments on different biological structures, and an imaging resolution of less than 120 nm was achieved in a more cost-effective manner. This study contributes to the real-time improvement of the imaging resolution of confocal microscopy and expands the application scenarios of confocal microscopy in biological imaging.

28 November 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
WLWenjie Liu
Wenjie Liu
MZMeng Zhang
Meng Zhang
WZWenbin Zhu
Wenbin Zhu
SXShunyu Xie
Shunyu Xie
JZJinfeng Zhang
Jinfeng Zhang
LSLothar Schermelleh
Lothar Schermelleh
Structured illumination microscopy (SIM) is a powerful method for fast and gentle live-cell super-resolution imaging. However, its susceptibility to reconstruction artifacts from out-of-focus blur and background imposes substantial barriers to analyze the dynamics of densely packed volumetric intraorganellar ultrastructures that are typically in a size range of SIM’s spatial resolution. To address this limitation, we have developed Lock-in-SIM, an open-access two-dimensional SIM framework that eliminates background and maximizes the recovery of sub-diffraction information with the highest possible frequency extraction. By leveraging the intrinsic modulation differences of volumetric sample structures, Lock-in-SIM enables efficient optical sectioning, extends imaging depth, and improves data fidelity and quantifiability. We demonstrate the superiority of Lock-in-SIM by visualizing various challenging intraorganellar ultrastructures in live cells. Our investigations uncover mechanisms of mitochondrial fission and endoplasmic reticulum-lysosome interactions and provide insights into the intricate yet highly regulated structural remodeling of organelles.