Bradley Chew

Mr. Bradley Chew

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2022 in Journal of Breath Research
Verified
Journal Article
Open access
BCBradley Chew
Bradley Chew
RCRaquel Pimentel Contreras
Raquel Pimentel Contreras
MMMitchell McCartney
Mitchell McCartney
EBEva Borras
Eva Borras
NKNicholas J Kenyon
Nicholas J Kenyon
CDCristina Davis
Cristina Davis
Exhaled breath vapor contains hundreds of volatile organic compounds (VOCs), which are the byproducts of health and disease metabolism, and they have clinical and diagnostic potential. Simultaneous collection of breath VOCs and background environmental VOCs is important to ensure analyses eliminate exogenous compounds from clinical studies. We present a mobile sampling system to extract gaseous VOCs onto commercially available sorbent-packed thermal desorption tubes. The sampler can be connected to a number of commonly available disposable and reusable sampling bags, in the case of this study, a Tedlar bag containing a breath sample. Alternatively, the inlet can be left open to directly sample room or environmental air when obtaining a background VOC sample. The system contains a screen for the operator to input a desired sample volume. A needle valve allows the operator to control the sample flow rate, which operates with an accuracy of −1.52 ± 0.63% of the desired rate, and consistently generated that rate with 0.12 ± 0.06% error across repeated measures. A flow pump, flow sensor and microcontroller allow volumetric sampling, as opposed to timed sampling, with 0.06 ± 0.06% accuracy in the volume extracted. Four samplers were compared by sampling a standard chemical mixture, which resulted in 6.4 ± 4.7% error across all four replicate modular samplers to extract a given VOC. The samplers were deployed in a clinical setting to collect breath and background/environmental samples, including patients with active SARS-CoV-2 infections, and the device could easily move between rooms and can undergo required disinfection protocols to prevent transmission of pathogens on the case exterior. All components required for assembly are detailed and are made publicly available for non-commercial use, including the microcontroller software. We demonstrate the device collects volatile compounds, including use of chemical standards, and background and breath samples in real use conditions.

2 November 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
NTNhi N. Trinh
Nhi N. Trinh
LSLeslie A. Simms
Leslie A. Simms
BCBradley Chew
Bradley Chew
AWAlexander Weinstein
Alexander Weinstein
VSValeria La Saponara
Valeria La Saponara
CDCristina Davis
Cristina Davis
A bonding process was developed for glass-to-glass fusion bonding using Borofloat 33 wafers, resulting in high bonding yield and high flexural strength. The Borofloat 33 wafers went through a two-step process with a pre-bond and high-temperature bond in a furnace. The pre-bond process included surface activation bonding using O2 plasma and N2 microwave (MW) radical activation, where the glass wafers were brought into contact in a vacuum environment in an EVG 501 Wafer Bonder. The optimal hold time in the EVG 501 Wafer bonder was investigated and concluded to be a 3 h hold time. The bonding parameters in the furnace were investigated for hold time, applied force, and high bonding temperature. It was concluded that the optimal parameters for glass-to-glass Borofloat 33 wafer bonding were at 550 °C with a hold time of 1 h with 550 N of applied force.

7 August 2024 in Chemosensors
Verified
Journal Article
Open access
PDF file
RCRaquel Pimentel Contreras
Raquel Pimentel Contreras
DKDylan Koch
Dylan Koch
PGPatrick Gibson
Patrick Gibson
MMMitchell McCartney
Mitchell McCartney
BCBradley Chew
Bradley Chew
CDCristina Davis
Cristina Davis
In this work, we describe the design, manufacturing development, and refinement of a chemical detection platform designed to identify specific odorants in the natural gas industry. As the demand for reliable and sensitive volatile organic compound (VOC) detection systems is growing, our project aimed to construct multiple prototypes to enhance our detection capabilities and provide portable detection platforms. Throughout the development process across nominally identical and duplicated instruments, various failure modes were encountered, which provided insight into the design and manufacturing challenges present when designing such platforms. We conducted a post hoc root cause analysis for each failure mode, leading to a series of design modifications and solutions. This paper details these design and manufacturing challenges, the analytical methods used to diagnose and address them, and the resulting improvements in system performance. In the end, a debugging flow chart is presented to aid future researchers in solving the possible issues that could be encountered. Our findings show the complexities of bespoke chemical sensor design for unique applications and highlight the critical importance of iterative testing and problem-solving in the development of industrial detection technologies. Achieving consistency across devices is essential for optimizing device-to-device efficiency. The work presented is the first step towards ensuring uniform performance across a production run of chemically sensitive devices. In the future, a universal device calibration model will be implemented, eliminating the need to collect data from each individual device.

21 May 2026 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
BCBradley Chew
Bradley Chew
DKDylan T. Koch
Dylan T. Koch
PGPatrick Gibson
Patrick Gibson
MMMitchell McCartney
Mitchell McCartney
EBEva Borras
Eva Borras
CDCristina Davis
Cristina Davis
We have engineered, fabricated, and qualified ZAPPI ( Z onal A tmospheric P ressure P lasma I onizer), an array of hollow electrical discharge emitter micro needles for volatile organic compound ionization and detection. The device is optimized for portable applications requiring low power and trace analyte abundance. The 250 µm interelectrode gap requires just 1.1 mW, detecting analytes at $$\dot{m}=23{ng}{s}^{-1}$$ m ̇ = 23 ng s − 1 mass flow rates. We further demonstrate ZAPPI’s efficacy by ionizing several compounds representing different point of detection applications. These compounds include DMMP a simulated chemical warfare nerve agent, 2-butanone a widely studied biomarker in exhaled breath, Methyl salicylate a flavoring agent, and Naphthalene a toxic polycyclic aromatic hydrocarbon by-product in combustion. The wafer level fabrication of the ZAPPI device opens future possibilities for highly integrated trace gas detection lab on chip systems.